A New, Specular Reflection- Based, Precorneal Tear Film Stability Measurement Technique in a Rabbit Model: Viscoelastic Increases Tear Film Stability

被引:5
|
作者
Nankivil, Derek [1 ]
Gonzalez, Alex [1 ]
Arrieta, Esdras [1 ]
Rowaan, Cornelis [1 ]
Aguilar, Mariela C. [1 ]
Sotolongo, Krystal [1 ]
Cabot, Florence A. [1 ,2 ]
Yoo, Sonia H. [1 ,2 ]
Parel, Jean-Marie A. [1 ,2 ,3 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Ophthalm Biophys Ctr, Miami, FL 33136 USA
[2] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Anne Bates Leach Eye Hosp, Miami, FL 33136 USA
[3] Brien Holden Vis Inst, Sydney, NSW, Australia
关键词
balanced salt solution; corneal hydration; evaporation; precorneal tear film stability; viscoelastic; BALANCED SALT-SOLUTION; CORNEAL THICKNESS; CATARACT-SURGERY; EYE DROPS;
D O I
10.1167/iovs.14-14157
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. METHODS. Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination. The software characterized the shape of the reflection, which became distorted as the precorneal tear film evaporated; characterization was accomplished by fitting an ellipse to the reflection and measuring its projected surface area. Balanced salt solution Plus (BSS+) and a 2% hydroxypropylmethylcellulose viscoelastic were used as the test agents. The tear film evaporation rate was characterized and compared over a period of 20 minutes in 20 eyes from 10 New Zealand white rabbits. RESULTS. The ellipse axes ratio and surface area were found to decrease initially after each application of either viscoelastic or BSS+ and then to increase linearly as the tear film began to evaporate (P < 0.001) for eyes treated with BSS+ only. Eyes treated with BSS+ required 7.5 +/- 2.7 applications to maintain sufficient corneal hydration during the 20-minute test period, whereas eyes treated with viscoelastic required 1.4 +/- 0.5 applications. The rates of evaporation differed significantly (P < 0.043) between viscoelastic and BSS+. CONCLUSIONS. The shape and surface area of the corneal reflection are strongly correlated with the state of the tear film. Rabbits' corneas treated with viscoelastic remained hydrated significantly longer than corneas treated with BSS+.
引用
收藏
页码:4158 / 4163
页数:6
相关论文
共 30 条
  • [1] PRECORNEAL TEAR FILM, STRUCTURE AND STABILITY
    PROUST, JE
    ARENAS, E
    PETROUTSOS, G
    POULIQUEN, Y
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1983, 6 (12): : 963 - 969
  • [2] EFFECT OF BENZALKONIUM CHLORIDE ON STABILITY OF PRECORNEAL TEAR FILM IN RABBIT AND MAN
    WILSON, WS
    DUNCAN, AJ
    JAY, JL
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1975, 59 (11) : 667 - 669
  • [3] DIURNAL-VARIATION IN PRECORNEAL TEAR FILM STABILITY
    PATEL, S
    BEVAN, R
    FARRELL, JC
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1988, 65 (03): : 151 - 154
  • [4] Possible Factors That Determine Precorneal Tear Film Stability
    Yokoi, N.
    Sakai, R.
    Kinoshita, S.
    Mizukusa, Y.
    Bron, A. J.
    Tiffany, J. M.
    Georgiev, G. A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] AGE-RELATED-CHANGES IN PRECORNEAL TEAR FILM STABILITY
    PATEL, S
    FARRELL, JC
    OPTOMETRY AND VISION SCIENCE, 1989, 66 (03) : 175 - 178
  • [6] The influence of tear proteins on the film stability of rabbit tear extracts
    Schoenwald, RD
    Vidvauns, S
    Wurster, DE
    Barfknecht, CF
    JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 1998, 14 (01) : 15 - 29
  • [7] RELATION BETWEEN PRECORNEAL TEAR FILM STABILITY AND TEAR PRODUCTION-RATE IN NORMAL EYES
    PATEL, S
    FARRELL, J
    BEVAN, R
    OPTOMETRY AND VISION SCIENCE, 1989, 66 (05) : 300 - 303
  • [8] Stability of the precorneal tear film in Chinese, African, Indian, and Caucasian eyes
    Patel, S
    Virhia, SK
    Farrell, P
    OPTOMETRY AND VISION SCIENCE, 1995, 72 (12) : 911 - 915
  • [9] A NEW HYPOTHESIS ON TEAR FILM STABILITY
    LIOTET, S
    VANBIJSTERVELD, OP
    KOGBE, O
    LAROCHE, L
    OPHTHALMOLOGICA, 1987, 195 (03) : 119 - 124
  • [10] Fluorescein tear breakup time measurement disrupts tear film stability
    Lin, Meng C.
    Graham, Andrew D.
    Yeh, Thao
    Yuen, Tiffany
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)