Seismic sensitivity indicators for tall guyed telecommunication towers

被引:14
|
作者
Amiri, GG [1 ]
机构
[1] Iran Univ Sci & Technol, Dept Civil Engn, Tehran 16844, Iran
基金
加拿大自然科学与工程研究理事会;
关键词
earthquake; dynamic analysis; telecommunication towers; guyed towers; sensitivity indicators; geometric nonlinearity;
D O I
10.1016/S0045-7949(01)00175-4
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Very tall towers are a fundamental component of post-disaster communication systems and their protection during a severe earthquake is of high priority. In North America. there are no simple rules to evaluate the seismic sensitivity of guyed masts. and very limited attention has been paid to the seismic behaviour of such structures to date. Since guyed towers may exhibit significant geometric nonlinearities, their detailed nonlinear seismic analysis is complex and time-consuming. In addition, climatic loads such as wind and ice are likely to govern their design in most cases. As a result, earthquake effects are often ignored or improperly evaluated. The objective of this paper is to propose some seismic sensitivity indicators for tall guyed masts, which would help tower designers decide whether seismic effects are important and whether detailed dynamic analysis of the structure is required. The indicators proposed relate to the maximum base shear and the dynamic component of the axial force in the mast and guy cable tensions. A conceptual model is also presented to explain the distribution of earthquake effects along tower elevation. The study is based on detailed nonlinear seismic analyses of eight existing guyed telecommunication towers with heights varying from 150 to 607 m. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:349 / 364
页数:16
相关论文
共 50 条
  • [31] Free vibration of guyed antenna towers
    Wahba, YMF
    Madugula, MKS
    Monforton, GR
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1996, : 1095 - 1100
  • [32] Tall towers
    Tahir, N
    TECHNOLOGY REVIEW, 2004, 107 (08) : 14 - 14
  • [33] TALL TOWERS
    不详
    CONCRETE, 1967, 1 (10): : 359 - &
  • [34] Seismic response of tall guyed masts to asynchronous multiple-support and vertical ground motions
    Faridafshin, Farzad
    McClure, Ghyslaine
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2008, 134 (08): : 1374 - 1382
  • [35] POST-BUCKLING ANALYSIS OF GUYED TOWERS
    CHAJES, A
    LING, D
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1981, 107 (12): : 2313 - 2323
  • [36] Guyed Wind Turbine Towers: Developments and outlook
    Jespersen, Martin
    Støttrup-Andersen, Ulrik
    ce/papers, 2019, 3 (3-4): : 779 - 784
  • [37] MINIMUM WEIGHT SIZING OF GUYED ANTENNA TOWERS
    GREENE, WH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1985, 111 (10): : 2121 - 2137
  • [38] POST-CRITICAL BEHAVIOR OF GUYED TOWERS
    DOMOKOS, G
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1989, 69 (05): : T373 - T376
  • [39] POST-BUCKLING ANALYSIS OF GUYED TOWERS
    Chajes, Alexander
    Ling, David
    1981, 107 (12): : 2313 - 2323
  • [40] SEISMIC RESPONSE OF 4-LEGGED SELF-SUPPORTING TELECOMMUNICATION TOWERS
    Amiri, G. Ghodrati
    Massah, S. R.
    Boostan, A.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2007, 20 (02): : 107 - 126