共 50 条
Some analytical considerations on the measurement of prostate-specific antigen
被引:0
|作者:
Blijenberg, BG
Kranse, R
Eman, I
Schroder, FH
机构:
[1] UNIV ROTTERDAM HOSP,DEPT CLIN CHEM,ROTTERDAM,NETHERLANDS
[2] UNIV ROTTERDAM HOSP,DEPT UROL,ROTTERDAM,NETHERLANDS
来源:
EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY
|
1996年
/
34卷
/
10期
关键词:
D O I:
暂无
中图分类号:
Q5 [生物化学];
Q7 [分子生物学];
学科分类号:
071010 ;
081704 ;
摘要:
In this study, various analytical aspects of the determination of serum prostate-specific antigen are described as applied to the Abbott IMx PSA and the Hybritech Tandem-E PSA assays. We used mainly specimens from a prostate cancer screening study in progress. A very good comparability between the assays proved to exist in our hands. The long-run variation (16 months) was also rated as acceptable, both for the IMx and the Tandem-E method. The method of choice, Tandem-E, showed good reagent stability over this period. We found, however, a difference in accuracy (Tandem-E +/- 8% higher values) that could not be explained by comparison with Tandem-R.
引用
收藏
页码:817 / 821
页数:5