Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system

被引:8
|
作者
Ippolito, Edy [1 ]
Fiore, Michele [1 ]
Di Donato, Alessia [1 ]
Silipigni, Sonia [1 ]
Rinaldi, Carla [1 ]
Cornacchione, Patrizia [1 ]
Infusino, Erminia [1 ]
Di Venanzio, Cristina [1 ]
Greco, Carlo [1 ]
Trodella, Lucio [1 ]
Ramella, Sara [1 ]
D'Angelillo, Rolando Maria [1 ]
机构
[1] Univ Campus Biomed, Radiat Oncol, Rome, Italy
来源
PLOS ONE | 2018年 / 13卷 / 05期
关键词
ADAPTED RADIOTHERAPY; RADIATION; CANCER; REDUCTION;
D O I
10.1371/journal.pone.0195506
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Voluntary deep inspiration breath hold technique (vDIBH) is considered as the key to achieving the widest cardiac sparing in whole breast irradiation. Several techniques have been implemented to achieve a reproducible, fast and friendly treatment. The aim of the present study is to implement vDIBH using the ExacTrac (BrainLAB AG, Germany) monitoring system. Methods Women with left-sided breast cancer, younger than 50 years or with cardiac disease, underwent whole breast RT with vDIBH using the ExacTrac (BrainLAB AG, Germany) monitoring system. Simulations were performed with patients positioned supine on a breast board with both arms raised above the head. Five optical markers were placed on the skin around the border of the left breast gland and their position was referenced with ink marking. Each patient received a training session to find the individual deep inspiration level. Finally, a vDIBH CT was taken. All patients were also studied in free breathing (FB) in order to compare the dose distribution for PTV, heart and left anterior descending coronary artery (LAD). Pre-treatment verification was carried out through the ExacTrac (BrainLAB AG, Germany) system and verified with electronic portal imaging (EPI). Moreover, daily real time EPIs in during modality (captured during the beam delivery) were taken in order to check the reproducibility. Results 34 patients have been evaluated and 30 were eligible for vDIBH. Most patients showed small setup errors during the treatment course of below 5 mm in 94.9% of the recorded fields. Mean Displacement was less in cranio-caudal direction. Mean intra-fraction displacement was below 3 mm in all directions. vDIBH plans provided better cardiac dosimetry. Conclusions vDIBH technique using ExacTrac (BrainLAB AG, Germany) monitoring system was applied with good reproducibility.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Evaluation of Reproducibility and Stability of Deep Inspiration Breath-Hold in Lung Stereotactic Body Radiation Therapy Using a Real-Time Tumor-Tracking Radiation Therapy System
    Kawazoe, Y.
    Shiinoki, T.
    Fujimoto, K.
    Yuasa, Y.
    Mukaidani, W.
    Tanaka, H.
    MEDICAL PHYSICS, 2024, 51 (09) : 6641 - 6641
  • [42] Evaluation of the Motion Range using Surface Mapping System during the Deep Inspiration Breath Hold for Left-Sided Breast Cancer Patients
    Jiang, W.
    Cao, D.
    Mehta, V. K.
    Shepard, D. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E587 - E587
  • [43] Reduction of Heart Dose Using Voluntary Deep Inspiration Breath-Holding Technique in Left Breast Cancer Patients Treated by Hypofractionated Radiation Therapy
    El-Badawy, S. A.
    Attiya, H.
    Mahmoud, M.
    El-Tagy, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E553 - E554
  • [44] Dosimetry and Feasibility Studies of Volumetric Modulated Arc Therapy With Deep Inspiration Breath-Hold Using Optical Surface Management System for Left-Sided Breast Cancer Patients
    Zhang, Wei
    Li, Ruisheng
    You, Dong
    Su, Yi
    Dong, Wei
    Ma, Zhao
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [45] Dosimetric comparison of deep inspiration breath hold and free breathing technique in stereotactic body radiotherapy for localized lung tumor using Flattening Filter Free beam
    Mani, Karthick Raj
    Bhuiyan, Md. Anisuzzaman
    Alam, Md. Mahbub
    Ahmed, Sharif
    Sumon, Mostafa Aziz
    Sengupta, Ashim Kumar
    Rahman, Md. Shakilur
    Islam, Md. S. M. Azharul
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2018, 24 (01): : 15 - 24
  • [46] Evaluation of Irregular Surface Compensator Technique Using Flatten Filter Free (FFF) for Deep Inspiration Breath Hold (DIBH) Left-Side Breast Radiation
    Peng, J. L.
    Ashenafi, M.
    McDonald, D. G.
    Mart, C.
    Koch, N. C.
    Harper, J. L.
    Godwin, W.
    Vanek, K. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E497 - E498
  • [47] Dosimetric Comparison of Deep Inspiration Breath Hold and Free Breathing Treatment Techniques for Left-sided Breast Cancer Using 3-Dimensional Surface Tracking
    Bourgeois, D. J., III
    Seghal, V.
    Dietrich, S.
    Yu, S.
    Kuo, J. V.
    Ramsinghani, N. S.
    Al-Ghazi, M.
    Daroui, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E36 - E36
  • [48] Chest Wall Motion During Active Deep Inspiration Breath Hold: A Study Using a Surface Mapping System in Left-Sided Breast Treatment
    Jiang, W.
    Cao, D.
    Mehta, V.
    Shepard, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E208 - E208
  • [49] Reproducibility of the abdominal and chest wall position by voluntary breath-hold technique using a laser-based monitoring and visual feedback system
    Nakamura, Katsumasa
    Shioyama, Yoshiyuki
    Nomoto, Satoru
    Ohga, Saiji
    Toba, Takashi
    Yoshitake, Tadamasa
    Anai, Shigeo
    Terashima, Hiromi
    Honda, Hiroshi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01): : 267 - 272
  • [50] Assessment of deep inspiration breath hold technique setup reproducibility using mega voltage imaging for left breast cancer radiation therapy-integrated network study
    Kim, HaYeon
    Huq, M. Saiful
    Heron, Dwight E.
    Lalonde, Ron
    Houser, Christopher J.
    Champ, Colin E.
    Beriwal, Sushil
    MEDICAL DOSIMETRY, 2020, 45 (01) : 28 - 33