Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors

被引:68
|
作者
Cai, QY
Park, J
Heldsinger, D
Hsieh, MD
Zellers, ET
机构
[1] Univ Michigan, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
vapor sensor; sensor array; acoustic-wave sensor; pattern recognition; vapor recognition; flexural plate wave;
D O I
10.1016/S0925-4005(99)00381-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preliminary testing of a prototype instrument employing an integrated array of six polymer-coated flexural plate wave (FPW) sensors and an adsorbent preconcentrator is described. Responses to thermally desorbed samples of individual organic solvent vapors and binary and ternary vapor mixtures are linear with concentration, and mixture responses are equivalent to the sums of the responses of the component vapors, which co-elute from the preconcentrator in most cases. Limits of detection as low as 0.3 ppm are achieved from a 60-s (34 cm(3)) air sample and peak widths at half-maximum range from 1 to 4 s. Tests at different flow rates suggest that the kinetics of vapor sorption in the sensor coating films may limit responses at higher flow rates, however, low data acquisition rates may also be contributory. Assessments of array performance using independent test data and Monte Carlo simulations with pattern recognition indicate that individual vapors and certain binary and ternary mixtures can be recognized/discriminated with very low error. More complex mixtures, and those containing homologous vapors, are problematic. This is the first report demonstrating multi-vapor analysis with an integrated FPW sensor array. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:121 / 130
页数:10
相关论文
共 50 条
  • [31] Highly sensitive pressure sensors based on conducting polymer-coated paper
    Zang, Xiaoling
    Jiang, Yuqian
    Wang, Xusheng
    Wang, Xiaowei
    Ji, Junhui
    Xue, Mianqi
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 1195 - 1201
  • [32] Optical sensors based on palladium and polymer-coated optical fiber resonators
    Bavili, N.
    Eryurek, M.
    Morova, B.
    Yilgor, I
    Yilgor, E.
    Kiraz, A.
    OPTICAL SENSORS 2019, 2019, 11028
  • [33] MEASURING THE WATER-CONTENT OF SYNTHETIC LUBRICANTS WITH POLYMER-COATED SENSORS
    CLOUGH, AE
    ANALYTICA CHIMICA ACTA, 1995, 315 (1-2) : 15 - 26
  • [34] DYNAMIC CALIBRATION OF QMB POLYMER-COATED SENSORS BY WIENER KERNEL ESTIMATION
    DAVIDE, FAM
    DINATALE, C
    DAMICO, A
    HIERLEMANN, A
    MITROVICS, J
    SCHWEIZER, M
    WEIMAR, U
    GOPEL, W
    MARCO, S
    PARDO, A
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 27 (1-3) : 275 - 285
  • [35] Passive and Remote Polymer-coated Love Wave Chemical Sensor
    Wang, Wen
    He, Shitang
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1854 - 1857
  • [36] Model-based optimal design of polymer-coated chemical sensors
    Phillips, C
    Jakusch, M
    Steiner, H
    Mizaikoff, B
    Fedorov, AG
    ANALYTICAL CHEMISTRY, 2003, 75 (05) : 1106 - 1115
  • [37] Dynamic calibration of QMB polymer-coated sensors by Wiener kernel estimation
    Davide, Fabrizio A.M.
    Di Natale, Corrado
    D'Amico, Arnaldo
    Hierlemann, Andreas
    Mitrovics, Jan
    Schweizer, Markus
    Weimar, Udo
    Gopel, Wolfgang
    Marco, Santiago
    Pardo, Antonio
    1995, Elsevier Science S.A., Lausanne, Switzerland (B27)
  • [38] The viscoelastic contribution to polymer-coated SAW sensor for TNT vapor detection
    Chen, Chen
    Yang, Mingyue
    Chen, Jing
    Liang, Chenxuan
    OPTIK, 2016, 127 (07): : 3638 - 3642
  • [39] Evaluation of a chemical vapor dosimeter using polymer-coated SERS substrates
    Stokes, DL
    Pal, A
    Narayanan, VA
    Vo-Dinh, T
    ANALYTICA CHIMICA ACTA, 1999, 399 (03) : 265 - 274
  • [40] Polymer-Coated Quartz Microbalance Sensors for Volatile Organic Compound Gases
    Strashilov, V. L.
    Alexieva, G. E.
    Velichkov, V. N.
    Mateva, R. P.
    Avramov, I. D.
    SENSOR LETTERS, 2009, 7 (02) : 203 - 211