An Inductively-Powered Wireless Neural Recording System With a Charge Sampling Analog Front-End

被引:33
|
作者
Lee, Seung Bae [1 ]
Lee, Byunghun [1 ]
Kiani, Mehdi [1 ]
Mahmoudi, Babak [2 ]
Gross, Robert [2 ]
Ghovanloo, Maysam [1 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, GT Bion Lab, Atlanta, GA 30308 USA
[2] Emory Univ, Dept Neurosurg, Atlanta, GA 30322 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Wireless neural recording; dual-slope charge sampling; wireless power transmission; stimulus artifact rejection; implantable medical devices; SMART EXPERIMENTAL ARENA; BRAIN;
D O I
10.1109/JSEN.2015.2483747
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An inductively-powered wireless integrated neural recording system (WINeR-7) is presented for wireless and battery-less neural recording from freely-behaving animal subjects inside a wirelessly powered standard homecage. The WINeR-7 system employs a novel wide-swing dual slope charge sampling (DSCS) analog front-end (AFE) architecture, which performs amplification, filtering, sampling, and analog-to-time conversion with minimal interference and small amount of power. The output of the DSCS-AFE produces a pseudodigital pulse-width modulated (PWM) signal. A circular shift register time-division multiplexes (TDM) the PWM pulses to create a TDM-PWM signal, which is fed into an on-chip 915-MHz transmitter (Tx). The AFE and Tx are supplied at 1.8 and 4.2 V, respectively, by a power management block, which includes a high efficiency active rectifier and automatic resonance tuning, operating at 13.56 MHz. The eight-channel system-on-a-chip was fabricated in a 0.35-mu m CMOS process, occupying 5x2.5 mm(2) and consumed 51.4 mW. For each channel, the sampling rate is 21.48 kHz and the power consumption is 19.3 mu W. In vivo experiments were conducted on freely-behaving rats in an energized homecage by continuously delivering 51.4 mW to the WINeR-7 system in a closed-loop fashion and recording local field potentials.
引用
收藏
页码:475 / 484
页数:10
相关论文
共 50 条
  • [41] A 2.4GHz low power wireless transceiver analog front-end for endoscopy capsule system
    Chi, Baoyong
    Yao, Jinke
    Han, Shuguang
    Xie, Xiang
    Li, Guolin
    Wang, Zhihua
    2006 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, PROCEEDINGS, 2006, : 4907 - +
  • [42] An Analog Front-End with Fast Motion Artifact Recovery for Bio-Signal Recording
    Jhong, Yu-Ting
    Huang, Po-Chiun
    2016 INTERNATIONAL SYMPOSIUM ON VLSI DESIGN, AUTOMATION AND TEST (VLSI-DAT), 2016,
  • [43] A 16-Channel TDM Analog Front-end with Enhanced System CMRR for Wearable Dry EEG Recording
    Tang, Tao
    Goh, Wang Ling
    Yao, Lei
    Gao, Yuan
    2017 IEEE ASIAN SOLID-STATE CIRCUITS CONFERENCE (A-SSCC), 2017, : 33 - 36
  • [44] Low-noise low-power front-end logarithmic amplifier for neural recording system
    Derafshi, Zahra Haddad
    Frounchi, Javad
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2014, 42 (05) : 437 - 451
  • [45] Fully-Differential Multichannel Integrated Neural Signal Recording Front-End
    Xiaoran Li
    Shun'an Zhong
    Haidong Yang
    Libin Yao
    Journal of Beijing Institute of Technology, 2017, 26 (02) : 228 - 234
  • [46] An ECG Recording Front-End With Continuous-Time Level-Crossing Sampling
    Li, Yongjia
    Mansano, Andre L.
    Yuan, Yuan
    Zhao, Duan
    Serdijn, Wouter A.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (05) : 626 - 635
  • [47] An Inductively Powered Scalable 32-Channel Wireless Neural Recording System-on-a-Chip for Neuroscience Applications
    Lee, Seung Bae
    Lee, Hyung-Min
    Kiani, Mehdi
    Jow, Uei-Ming
    Ghovanloo, Maysam
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2010, 4 (06) : 360 - 371
  • [48] Implantable analog front-end with high PSRR and CMRR for neural signal acquisition
    Wu, Zhao-Hui
    Xie, Yu-Zhi
    Zhao, Ming-Jian
    Li, Bin
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2015, 43 (01): : 15 - 20
  • [49] Neural recording front-end designs for fully implantable neuroscience applications and neural prosthetic microsystems
    Perlin, G. E.
    Sodagar, A. M.
    Wise, K. D.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 5578 - +
  • [50] An Ultra Compact Integrated Front End for Wireless Neural Recording Microsystems
    Perlin, Gayatri E.
    Wise, Kensall D.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2010, 19 (06) : 1409 - 1421