Development of a Field Deployable Firebrand Flux and Condition Measurement System

被引:0
|
作者
Zen, Simone [1 ]
Thomas, Jan C. [1 ]
Mueller, Eric V. [1 ]
Dhurandher, Bhisham [1 ]
Gallagher, Michael [2 ]
Skowronski, Nicholas [3 ]
Hadden, Rory M. [1 ]
机构
[1] Univ Edinburgh, Sch Engn, Edinburgh, Midlothian, Scotland
[2] US Forest Serv, USDA, Northern Res Stn, New Lisbon, NJ 15401 USA
[3] US Forest Serv, USDA, Northern Res Stn, Morgantown, WV 26505 USA
关键词
GENERATION;
D O I
10.1007/s10694-020-01074-x
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new instrument to quantify firebrand dynamics during fires with particular focus on those associated with the Wildland-Urban Interface (WUI) has been developed. During WUI fires, firebrands can ignite spot fires, which can rapidly increase the rate of spread (ROS) of the fire, provide a mechanism by which the fire can pass over firebreaks and are the leading cause of structure ignitions. Despite this key role in driving wildfire dynamics and hazards, difficulties in collecting firebrands in the field and preserving their physical condition (e.g. dimensions and temperature) have limited the development of knowledge of firebrand dynamics. In this work we present a new, field-deployable diagnostic tool, an emberometer, designed to provide measurement of firebrand fluxes and information on both the geometry and the thermal conditions of firebrands immediately before deposition by combining a visual and infrared camera. A series of laboratory experiments were conducted to calibrate and validate the developed imaging techniques. The emberometer was then deployed in the field to explore firebrand fluxes and particle conditions for a range of fire intensities in natural pine forest environments. In addition to firebrand particle characterization, field observations with the emberometer enabled detailed time history of deposition (i.e. firebrand flux) relative to concurrent in situ fire behaviour observations. We highlight that deposition was characterised by intense, short duration "showers" that can be reasonably associated to spikes in the average fire line intensity. The results presented illustrate the potential use of an emberometer in studying firebrand and spot fire dynamics.
引用
收藏
页码:1401 / 1424
页数:24
相关论文
共 50 条
  • [1] Development of a Field Deployable Firebrand Flux and Condition Measurement System
    Simone Zen
    Jan C. Thomas
    Eric V. Mueller
    Bhisham Dhurandher
    Michael Gallagher
    Nicholas Skowronski
    Rory M. Hadden
    [J]. Fire Technology, 2021, 57 : 1401 - 1424
  • [2] Flexible and Deployable Antenna Measurement System
    Giordanengo, G.
    Righero, M.
    Adorisio, G. Musacchio
    Mayer, F.
    Maurer, M.
    Peters, G.
    Dassano, G.
    Maggiora, R.
    Vecchi, G.
    Rolo, L.
    [J]. 2023 17TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2023,
  • [3] A remotely operated, Field Deployable Tritium Analysis System for surface and ground water measurement
    Cable, PR
    Hofstetter, KJ
    Beals, DM
    Jones, JD
    Collins, SL
    Noakes, JE
    Spaulding, JD
    Neary, MP
    Peterson, R
    [J]. FIELD ANALYTICAL METHODS FOR HAZARDOUS WASTES AND TOXIC CHEMICALS, 1997, : 345 - 352
  • [4] Development of a field-deployable voice-activated ultrasound scanner system
    Sebastian, D
    Pedersen, PC
    [J]. PROCEEDINGS OF THE IEEE 30TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2004, : 47 - 48
  • [5] A remotely operated, field-deployable tritium analysis system for surface and ground water measurement
    Noakes, JE
    Spaulding, JD
    Neary, MP
    [J]. RADIOCARBON, 1998, 40 (01) : 183 - 192
  • [6] Field-Deployable System for the Measurement of Complex Permittivity of Improvised Explosives and Lossy Dielectric Materials
    Gutierrez, Sergio
    Just, Thomas
    Sachs, Juergen
    Baer, Christoph
    Vega, Felix
    [J]. IEEE SENSORS JOURNAL, 2018, 18 (16) : 6706 - 6714
  • [7] Cablenet System Analysis for Deployable Antenna in Ground Test Condition
    You, Guoqiang
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON EDUCATION, MANAGEMENT, INFORMATION AND MECHANICAL ENGINEERING (EMIM 2017), 2017, 76 : 519 - 524
  • [8] Improved near-field scanning system for encircled flux measurement
    He, G.
    Breton, M.
    Dallaire-Poirier, S.
    Bull, G.
    Schinn, G. W.
    St-Amant, Y.
    Morel, J.
    Gambon, A.
    [J]. IET OPTOELECTRONICS, 2011, 5 (01) : 46 - 49
  • [9] Development of distortion measurement system for large deployable antenna via photogrammetry in vacuum and cryogenic environment
    Zhang Pengsong
    Jiang Shanping
    Yang Linhua
    Zhang Bolun
    [J]. 2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY - OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2017, 10621
  • [10] Development of a Deployable Physiological Assessment and Intervention System
    Russoniello, Carmen
    Evans, John
    Bart-Knauer, Brenda
    Fish, Matt
    Brown-Bochicchio, Christina
    Gremore, Laura
    Paluzzi, Mikayla
    Blocker, Daniel
    Collins, Meagan
    [J]. APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2016, 41 (04) : 435 - 435