A remotely operated, Field Deployable Tritium Analysis System for surface and ground water measurement

被引:0
|
作者
Cable, PR [1 ]
Hofstetter, KJ [1 ]
Beals, DM [1 ]
Jones, JD [1 ]
Collins, SL [1 ]
Noakes, JE [1 ]
Spaulding, JD [1 ]
Neary, MP [1 ]
Peterson, R [1 ]
机构
[1] Westinghouse Savannah River Co, Savannah River Technol Ctr, Aiken, SC 29808 USA
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A prototype system for the remote, in situ analysis of tritium in surface and ground waters has been developed at the Savannah River Site through the combined efforts of university, private industry, and government laboratory personnel under a project funded by the U. S. Department of Energy. Using automated liquid scintillation counting techniques, the Field Deployable Tritium Analysis System (FDTAS) has been shown in laboratory and field tests to have sufficient sensitivity to measure tritium in water samples at environmental levels (10 Bq/L [similar to 270 pCi/L] for a 100-minute count) on a near-real time basis. The FDTAS consists of a fixed volume sampler (50 mt), an on-line water purification system, and a stop-flow liquid scintillation counter for detecting tritium in the purified sample. All operations are controlled and monitored by a remote computer using standard telephone line modem communications. The FDTAS offers a cost-effective alternative to the expensive and time-consuming methods of field sample collection and laboratory analyses for tritium in contaminated groundwater.
引用
收藏
页码:345 / 352
页数:4
相关论文
共 50 条
  • [1] A remotely operated, field-deployable tritium analysis system for surface and ground water measurement
    Noakes, JE
    Spaulding, JD
    Neary, MP
    [J]. RADIOCARBON, 1998, 40 (01) : 183 - 192
  • [2] Field deployable tritium analysis system for ground and surface water measurements
    Hofstetter, KJ
    Cable, PR
    Beals, DM
    Noakes, JE
    Spaulding, JD
    Neary, MP
    Peterson, R
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 233 (1-2) : 201 - 205
  • [3] Field deployable tritium analysis system for ground and surface water measurements
    K. J. Hofstetter
    P. R. Cable
    D. M. Beals
    J. E. Noakes
    J. D. Spaulding
    M. P. Neary
    R. Peterson
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 1998, 233 : 201 - 205
  • [4] Remotely operated infrared radiometer for the measurement of atmospheric water vapor
    Naylor, DA
    Gom, BG
    Schofield, IS
    Tompkins, GJ
    Chapman, IM
    [J]. INFRARED TECHNOLOGY AND APPLICATIONS XXV111, PTS 1 AND 2, 2003, 4820 : 908 - 918
  • [5] Remotely Operated Vehicle System Implementation in Open-Water
    Mu, Ling-Ji
    Sardinha, Carlos
    Chen, Chin-Yin
    Yang, Ya-Chao
    Yu, Chao-Ming
    Chiu, Yi-Ming
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON INTELLIGENT TECHNOLOGIES AND ENGINEERING SYSTEMS (ICITES2013), 2014, 293 : 553 - 560
  • [6] Remotely operated measurement system for monitoring and diagnosis of electrical drives in the waste-water treatment plant
    Pawlak, Marcin
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (02): : 329 - 334
  • [7] Acoustic water bottom investigation with a remotely operated watercraft survey system
    Shintaro Yamasaki
    Tomonori Tabusa
    Shunsuke Iwasaki
    Masahiro Hiramatsu
    [J]. Progress in Earth and Planetary Science, 4
  • [8] Acoustic water bottom investigation with a remotely operated watercraft survey system
    Yamasaki, Shintaro
    Tabusa, Tomonori
    Iwasaki, Shunsuke
    Hiramatsu, Masahiro
    [J]. PROGRESS IN EARTH AND PLANETARY SCIENCE, 2017, 4
  • [9] Failure Analysis of Fasteners in a Remotely Operated Vehicle (ROV) System
    Chowdhury, T.
    Sathianarayanan, D.
    Dharani, G.
    Ramadass, G. A.
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2015, 15 (06) : 915 - 923
  • [10] Development of a Field Deployable Firebrand Flux and Condition Measurement System
    Zen, Simone
    Thomas, Jan C.
    Mueller, Eric V.
    Dhurandher, Bhisham
    Gallagher, Michael
    Skowronski, Nicholas
    Hadden, Rory M.
    [J]. FIRE TECHNOLOGY, 2021, 57 (03) : 1401 - 1424