High-resolution biophotonic tomography

被引:0
|
作者
Wang, LHV [1 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, Opt Imaging Lab, College Stn, TX 77843 USA
关键词
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We develop novel biophotonic imaging for early-cancer detection, a grand challenge in cancer research, using non-ionizing electromagnetic and ultrasonic waves. Unlike ionizing x-ray radiation, non-ionizing electromagnetic waves such as optical waves are safe for biomedical applications and reveal new contrast mechanisms and functional information. For example, our spectroscopic oblique- incidence reflectometry can detect skin cancers based on functional hemoglobin parameters and cell nuclear size with 95% accuracy. Unfortunately, electromagnetic waves in the non-ionizing spectral region do not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution tomography based on non-ionizing electromagnetic waves alone, as demonstrated by confocal microscopy and two-photon microscopy as well as our Mueller optical coherence tomography, is limited to superficial tissue imaging within similar to1 mm depth. Ultrasonic imaging, on the contrary, furnishes good imaging resolution but has poor contrast in early-stage tumors and has strong speckle artifacts as well. We developed ultrasound-mediated imaging modalities by combining electromagnetic and ultrasonic waves synergistically. The hybrid modalities yield speckle-free electromagnetic-contrast information at ultrasonic resolution in relatively large biological tissue. In photo-acoustic tomography, a diverged laser pulse induces ultrasonic waves in biological tissue due to thermoelastic expansion as a result of a small but rapid temperature rise. The short-wavelength ultrasonic waves are detected to form wavelength-limited high-resolution tomographic images of the tissue.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 50 条
  • [21] High-resolution computed tomography: Technique and pitfalls
    McGuinness, G
    SEMINARS IN ROENTGENOLOGY, 2002, 37 (01) : 5 - 16
  • [22] High-resolution computed tomography in rheumatoid arthritis
    Sema Yildiz
    Hasan Cece
    Ekrem Karakas
    Rheumatology International, 2012, 32 : 3703 - 3703
  • [23] HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF THE LUNGS
    WORTHY, S
    BRITISH MEDICAL JOURNAL, 1995, 310 (6980): : 615 - 616
  • [24] HIGH-RESOLUTION COMPUTED TOMOGRAPHY IN ALVEOLAR PROTEINOSIS
    Mehrian, P.
    CHEST, 2020, 157 (06) : 218A - 218A
  • [25] High-resolution computed tomography in rheumatoid arthritis
    Yildiz, Sema
    Cece, Hasan
    Karakas, Ekrem
    RHEUMATOLOGY INTERNATIONAL, 2012, 32 (11) : 3703 - 3703
  • [26] A HIGH-RESOLUTION DETECTION SYSTEM FOR POSITRON TOMOGRAPHY
    BARTON, JB
    HOFFMAN, EJ
    IWANCZYK, JS
    DABROWSKI, AJ
    KUSMISS, JH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (01) : 671 - 675
  • [27] HIGH-RESOLUTION COMPUTED TOMOGRAPHY OF POSITRON EMITTERS
    DERENZO, SE
    BUDINGER, TF
    CAHOON, JL
    HUESMAN, RH
    JACKSON, HG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 544 - 558
  • [28] HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF THE LUNG
    SWENSEN, SJ
    AUGHENBAUGH, GL
    BROWN, LR
    MAYO CLINIC PROCEEDINGS, 1989, 64 (10) : 1284 - 1294
  • [29] High-resolution process in ultrasonic reflection tomography
    Lasaygues, P
    Lefebvre, JP
    Bouvat-Merlin, M
    ACOUSTICAL IMAGING, VOL 24, 2000, 24 : 35 - 41
  • [30] THE HIGH-RESOLUTION COMPUTED-TOMOGRAPHY TECHNIQUE
    MAYO, JR
    SEMINARS IN ROENTGENOLOGY, 1991, 26 (02) : 104 - 109