Acoustic resolution photoacoustic Doppler flowmetry: practical considerations for obtaining accurate measurements of blood flow

被引:7
|
作者
Brunker, J. [1 ]
Beard, P. [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
关键词
Doppler; photoacoustic; pulsed; acoustic resolution; cross-correlation; flow; velocity; blood; CROSS-CORRELATION;
D O I
10.1117/12.2039619
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An assessment has been made of various experimental factors affecting the accuracy of flow velocities measured using a pulsed time correlation photoacoustic Doppler technique. In this method, Doppler time shifts are quantified via cross-correlation of pairs of photoacoustic waveforms generated in moving absorbers using pairs of laser light pulses, and the photoacoustic waves are detected using an ultrasound transducer. The acoustic resolution mode is employed by using the transducer focal width, rather than the large illuminated volume, to define the lateral spatial resolution. This enables penetration depths of several millimetres or centimetres, unlike methods using the optical resolution mode, which limits the maximum penetration depth to approximately 1 mm. In the acoustic resolution mode, it is difficult to detect time shifts in highly concentrated suspensions of flowing absorbers, such as red blood cell suspensions and whole blood, and this challenge supposedly arises because of the lack of spatial heterogeneity. However, by assessing the effect of different absorption coefficients and tube diameters, we offer an alternative explanation relating to light attenuation and parabolic flow. We also demonstrate a new signal processing method that surmounts the previous problem of measurement under-reading. This method is a form of signal range gating and enables mapping of the flow velocity profile across the tube as well as measurement of the average flow velocity. We show that, using our signal processing scheme, it is possible to measure the flow of whole blood using a relatively low frequency detector. This important finding paves the way for application of the technique to measurements of blood flow several centimetres deep in living tissue.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Blood flow measurements of optic nerve head rim tissue as a function of illumination with scanning laser Doppler flowmetry
    Embleton, SJ
    Hosking, SL
    Pettinger, C
    Kagemann, L
    Chabra, A
    Chung, HS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S276 - S276
  • [42] ASSESSMENT OF CANCELLOUS BONE BLOOD-FLOW BY LASER DOPPLER FLOWMETRY
    NILSSON, GE
    HELLEM, S
    JACOBSSON, L
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1982, 1 (03): : 299 - 299
  • [43] The use of laser Doppler flowmetry to evaluate anterior cruciate blood flow
    Schlehr, F.J.
    Limbird, T.A.
    Swiontkowski, M.F.
    Keller, T.S.
    1600, (05):
  • [44] LASER DOPPLER FLOWMETRY IN THE ASSESSMENT OF INTESTINAL BLOOD-FLOW IN MAN
    LINDHAGEN, J
    AHN, H
    SALERUD, EG
    JODAL, M
    LUNDGREN, O
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1984, 3 (3-4): : 478 - 478
  • [45] MEASUREMENT OF SKIN BLOOD-FLOW USING LASER DOPPLER FLOWMETRY
    SVENSSON, H
    JONSSON, BA
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 205 - 205
  • [46] GINGIVAL BLOOD-FLOW STUDIES USING LASER DOPPLER FLOWMETRY
    OBERG, PA
    BAAB, DA
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1647 - 1649
  • [47] Reliability of Skin Blood Flow Measures by Laser-Doppler Flowmetry
    Herron, Robert
    Carter, Stephen
    Collins, Ann
    Leatherwood, Matthew
    FASEB JOURNAL, 2015, 29
  • [48] Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse
    Adair, HS
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS VIII, PROCEEDINGS OF, 1998, 3245 : 422 - 425
  • [49] LASER-DOPPLER FLOWMETRY FOR ESTIMATING LIVER BLOOD-FLOW
    ARVIDSSON, D
    SVENSSON, H
    HAGLUND, U
    AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (04): : G471 - G476
  • [50] Measurement of blood flow in the rotator cuff using laser Doppler flowmetry
    Levy, O.
    Relwani, J.
    Zaman, T.
    Even, T.
    Venkateswaran, B.
    Copeland, S.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (07): : 893 - 898