Risk Factors of Infection and Role of Antibiotic Prophylaxis in Totally Implantable Venous Access Port Placement: Propensity Score Matching

被引:13
|
作者
Nezami, Nariman [1 ]
Xing, Minzhi [2 ]
Groenwald, Matthew [1 ]
Silin, Douglas [1 ]
Kokabi, Nima [3 ]
Latich, Igor [1 ]
机构
[1] Yale Univ, Sch Med, Dept Radiol & Biomed Imaging, Div Intervent Radiol, 333 Cedar St, New Haven, CT 06520 USA
[2] Johns Hopkins Univ, Johns Hopkins Bloomberg Sch Publ Hlth, Baltimore, MD USA
[3] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Div Intervent Radiol, Atlanta, GA USA
关键词
Port; Antibiotic; Prophylaxis; Infection; Removal; Central venous; Catheter; DEVICE PLACEMENT; COMPLICATIONS; HEMODIALYSIS; EXPERIENCE;
D O I
10.1007/s00270-019-02255-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundTo evaluate risk factors of infection and effectiveness of preprocedural single-dose intravenous prophylactic antibiotic (PABX) during totally implantable venous access port (TIVAP) placement in preventing procedure-related infections.MethodsThis was a retrospective single-institution multicenter study evaluating short-term (30-day) infection outcomes after TIVAP placement. Correlation between infection rates and clinical factors, including hematologic versus non-hematologic malignancy, inpatient versus outpatient status, single versus double lumen and PABX, was investigated using univariate and multivariable analysis in the overall study population as well as the propensity-score-matched cohort.ResultsOverall, 5967 patients underwent TIVAP placement from 2005 to 2016, of which 3978 (67%) patients received PABX. On propensity score matching, 1952 patients with PABX were matched to the same number of patients without PABX. TIVAP was removed due to infection concern in 48 patients in unmatched and 30 patients in matched population. There was no difference in the rate of infection between those who received PABX and those who did not in both unmatched and matched population (p=0.5387 and 0.9999). Although infection rate was significantly higher in patients who had TIVAP placement in inpatient setting (p<0.0001), who received a double-lumen TIVAP (p<0.0001), or who had hematologic malignancy (p=0.0004) on univariate analysis, inpatient status was the sole factor associated with higher rate of TIVAP infection on multivariable analysis of both overall (odds ratio 2.31, p<0.0001) and matched populations (odds ratio 4.36, p=0.0004).ConclusionPlacement of TIVAP in inpatient setting increases the risk of TIVAP infection. PABX before TIVAP placement does not prevent short-term procedure-related infections.
引用
收藏
页码:1302 / 1310
页数:9
相关论文
共 50 条
  • [11] Accessing totally implantable venous access systems on the day of placement does not significantly increase the risk of infection
    Young, Shamar J.
    Young, Linda J.
    Vogel, Jeffery
    Sutkowski, Raymond
    Venkataperumal, Satish
    Journal of Vascular Access, 2016, 17 (03): : 261 - 264
  • [12] Incidence, prevalence and risk factors for a first infectious complication on a totally implantable venous-access port
    Crisinel, M.
    Mahy, S.
    Ortega-Debalon, P.
    Buisson, M.
    Favre, J. -P.
    Chavanet, P.
    Piroth, L.
    MEDECINE ET MALADIES INFECTIEUSES, 2009, 39 (04): : 252 - 258
  • [13] Totally implantable central venous access port infections in patients with digestive cancer: Incidence and risk factors
    Toure, Abdoulaye
    Vanhems, Philippe
    Lombard-Bohas, Catherine
    Cassier, Philippe
    Pere-Verge, Denis
    Souquet, Jean-Christophe
    Ecochard, Rene
    Chambrier, Cecile
    AMERICAN JOURNAL OF INFECTION CONTROL, 2012, 40 (10) : 935 - 939
  • [14] Routine Antibiotic Prophylaxis for Totally Implantable Venous Access Device Placement: Meta-Analysis of 2,154 Patients
    Johnson, Evan
    Babb, James
    Sridhar, Divya
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (03) : 339 - 343
  • [15] Femoral placement of a totally implantable venous access port with spontaneous catheter fracture: case report
    Tomohiro Kondo
    Shigemi Matsumoto
    Keitaro Doi
    Motoo Nomura
    Manabu Muto
    CVIR Endovascular, 3
  • [16] Femoral placement of a totally implantable venous access port with spontaneous catheter fracture: case report
    Kondo, Tomohiro
    Matsumoto, Shigemi
    Doi, Keitaro
    Nomura, Motoo
    Muto, Manabu
    CVIR ENDOVASCULAR, 2020, 3 (01)
  • [17] Innominate vein stenosis in breast cancer patients after totally implantable venous access port placement
    Song, Myung Gyu
    Seo, Tae-Seok
    Kang, Eun Young
    Yong, Hwan Seok
    Seo, Jae Hong
    Choi, Yoon Young
    JOURNAL OF VASCULAR ACCESS, 2015, 16 (04): : 315 - 320
  • [18] Risk factors for central line-associated bloodstream infection in pediatric oncology patients with a totally implantable venous access port: A cohort study
    Viana Taveira, Michelle Ribeiro
    Lima, Luciana Santana
    de Araujo, Claudia Correa
    Goncalves de Mello, Maria Julia
    PEDIATRIC BLOOD & CANCER, 2017, 64 (02) : 336 - 342
  • [19] Could antibiotic prophylaxis be not necessary to implant totally implantable venous access devices? Randomized prospective study
    Di Carlo, Isidoro
    Toro, Adriana
    Pulvirenti, Elia
    Palermo, Filippo
    Scibilia, Giuseppe
    Cordio, Stefano
    SURGICAL ONCOLOGY-OXFORD, 2011, 20 (01): : 20 - 25
  • [20] Unnecessary perioperative antibiotic prophylaxis in the placement of totally implanted central venous access ports should be avoided
    Cataldo, Maria Adriana
    Petrosillo, Nicola
    AMERICAN JOURNAL OF SURGERY, 2012, 204 (04): : 555 - 556