Imaging of dopamine transporters in rats using high-resolution pinhole single-photon emission tomography

被引:40
|
作者
Booij, J
de Bruin, K
Habraken, JBA
Voorn, P
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, NL-1105 AZ Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Anat, Amsterdam, Netherlands
关键词
dopamine transporter imaging; rats; single pinhole; SPET; variability; reproducibility;
D O I
10.1007/s00259-002-0845-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To date, the vast majority of investigations on the dopaminergic system in small animals have been in vitro studies. In comparison with in vitro studies, single-photon emission tomography (SPET) or positron emission tomography (PET) imaging of the dopaminergic system in small animals has the advantage of permitting repeated studies within the same group of animals. Dopamine transporter imaging is a valuable non-invasive tool with which to investigate the integrity of dopaminergic neurons. The purpose of this study was to investigate the feasibility of assessing dopamine transporter density semiquantitatively in rats using a recently developed high-resolution pinhole SPET system. This system was built exclusively for imaging of small animals. In this unique single-pinhole system, the animal rotates instead of the collimated detector. The system has proven to have a high spatial resolution. We performed SPET imaging with [I-123]FP-CIT to quantify striatal dopamine transporters in rat brain. In all seven studied control rats, symmetrical striatal binding to dopamine transporters was seen 2 h after injection of the radiotracer, with striatal-to-cerebellar binding ratios of approximately 3.5. In addition, test/retest variability of the striatal-to-cerebellar binding ratios was studied and found to be 14.5%. Finally, in unilaterally 6-hydroxydopamine-lesioned rats, striatal binding was only visible on the non-lesioned side. Quantitative analysis revealed that striatal-to-cerebellar SPET ratios were significantly lower on the lesioned (mean binding ratio 2.2 +/- 0.2) than on the non-lesioncd (mean ratio 3.1 +/- 0.4) side. The preliminary results of this study indicate that semi-quantitative assessment of striatal dopamine transporter density using our recently developed high-resolution single-pinhole SPET system is feasible in living rat brain.
引用
下载
收藏
页码:1221 / 1224
页数:4
相关论文
共 50 条
  • [41] Dynamic Observation of the Three-Dimensional Distribution of Labeled Liposomes Using the Novel High-Resolution Single-Photon Emission Computed Tomography
    Wirrwar, Andreas
    Buchholz, Doris
    Gottschalk, Oliver
    Viehoever, Sandra
    Schramm, Nils Uwe
    Mueller, Hans-Wilhelm
    MOLECULAR IMAGING, 2008, 7 (05) : 234 - 238
  • [42] Imaging of the dopaminergic neurotransmission system using single-photon emission tomography and positron emission tomography in patients with parkinsonism
    Booij, J
    Tissingh, G
    Winogrodzka, A
    van Royen, EA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (02) : 171 - 182
  • [43] Imaging of the dopaminergic neurotransmission system using single-photon emission tomography and positron emission tomography in patients with parkinsonism
    Graduate School of Neurosciences Amsterdam, Department of Nuclear Medicine, Academic Medical Center, Meibergdreef 9, Amsterdam, Netherlands
    不详
    不详
    Eur. J. Nucl. Med. Mol. Imaging, 2 (171-182):
  • [44] Imaging of the dopaminergic neurotransmission system using single-photon emission tomography and positron emission tomography in patients with parkinsonism
    Jan Booij
    Gerrit Tissingh
    Ania Winogrodzka
    Eric A. van Royen
    European Journal of Nuclear Medicine, 1999, 26 : 171 - 182
  • [45] SINGLE-PHOTON TRACERS FOR SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    KUNG, HF
    ACADEMIC RADIOLOGY, 1995, 2 : S94 - S95
  • [46] SMALL-ANIMAL MOLECULAR IMAGING WITH PORTABLE DEVICES ON CLINICAL PINHOLE SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY SYSTEMS
    Hu, Chi-Min
    Lin, Ming-Shien
    Su, Kuan-Hao
    Liu, Ren-Shyan
    Chen, Jyh-Cheng
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2012, 24 (06): : 485 - 493
  • [47] Dual-isotope single-photon emission computed tomography for dopamine and serotonin transporters in normal and parkinsonian monkey brains
    Li, I-Hsun
    Huang, Wen-Sheng
    Yeh, Chin-Bin
    Liao, Mei-Hsiu
    Chen, Chia-Chieh
    Shen, Lie-Hang
    Liu, Jiang-Chuan
    Ma, Kuo-Hsing
    NUCLEAR MEDICINE AND BIOLOGY, 2009, 36 (06) : 605 - 611
  • [48] QUANTITATIVE SINGLE-PHOTON EMISSION TOMOGRAPHY
    SNYDER, D
    MILLER, M
    MILLER, T
    CHEN, CJ
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 1006 - 1006
  • [49] Single-photon emission computed tomography-computed tomography in imaging infection
    Navalkissoor, Shaunak
    Nowosinska, Ewa
    Gnanasegaran, Gopinath
    Buscombe, John R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (04) : 283 - 290
  • [50] Single-photon emission tomography imaging of serotonin transporters in the nonhuman primate brain with [123I]ODAM
    Paul D. Acton
    Mu Mu
    Karl Plössl
    Catherine Hou
    Michael Siciliano
    Zhi-Ping Zhuang
    Shunichi Oya
    Seok-Rye Choi
    Hank F. Kung
    European Journal of Nuclear Medicine, 1999, 26 : 1359 - 1362