Imaging of dopamine transporters in rats using high-resolution pinhole single-photon emission tomography

被引:40
|
作者
Booij, J
de Bruin, K
Habraken, JBA
Voorn, P
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, NL-1105 AZ Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Ctr, Dept Anat, Amsterdam, Netherlands
关键词
dopamine transporter imaging; rats; single pinhole; SPET; variability; reproducibility;
D O I
10.1007/s00259-002-0845-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To date, the vast majority of investigations on the dopaminergic system in small animals have been in vitro studies. In comparison with in vitro studies, single-photon emission tomography (SPET) or positron emission tomography (PET) imaging of the dopaminergic system in small animals has the advantage of permitting repeated studies within the same group of animals. Dopamine transporter imaging is a valuable non-invasive tool with which to investigate the integrity of dopaminergic neurons. The purpose of this study was to investigate the feasibility of assessing dopamine transporter density semiquantitatively in rats using a recently developed high-resolution pinhole SPET system. This system was built exclusively for imaging of small animals. In this unique single-pinhole system, the animal rotates instead of the collimated detector. The system has proven to have a high spatial resolution. We performed SPET imaging with [I-123]FP-CIT to quantify striatal dopamine transporters in rat brain. In all seven studied control rats, symmetrical striatal binding to dopamine transporters was seen 2 h after injection of the radiotracer, with striatal-to-cerebellar binding ratios of approximately 3.5. In addition, test/retest variability of the striatal-to-cerebellar binding ratios was studied and found to be 14.5%. Finally, in unilaterally 6-hydroxydopamine-lesioned rats, striatal binding was only visible on the non-lesioned side. Quantitative analysis revealed that striatal-to-cerebellar SPET ratios were significantly lower on the lesioned (mean binding ratio 2.2 +/- 0.2) than on the non-lesioncd (mean ratio 3.1 +/- 0.4) side. The preliminary results of this study indicate that semi-quantitative assessment of striatal dopamine transporter density using our recently developed high-resolution single-pinhole SPET system is feasible in living rat brain.
引用
收藏
页码:1221 / 1224
页数:4
相关论文
共 50 条
  • [1] Imaging of dopamine transporters in rats using high-resolution pinhole single-photon emission tomography
    Jan Booij
    Kora de Bruin
    Jan B. Habraken
    Pieter Voorn
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2002, 29 : 1221 - 1224
  • [2] Myocardial infarction in rats: High-resolution single-photon emission tomographic imaging with a pinhole collimator
    Yukihiro, M
    Inoue, T
    Iwasaki, T
    Tomiyoshi, K
    Erlandsson, K
    Endo, K
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (08): : 896 - 900
  • [3] Myocardial infarction in rats: High resolution single-photon emission tomography imaging with pinhole collimator.
    Yukihiro, M
    Inoue, T
    Iwasaki, T
    Tomiyoshi, K
    Tateno, M
    Erlandsson, K
    Endo, K
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 698 - 698
  • [4] Quantification of dopamine transporters in the mouse brain using ultra-high resolution single-photon emission tomography
    Paul D. Acton
    Seok-Rye Choi
    Karl Plössl
    Hank F. Kung
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2002, 29 : 691 - 698
  • [5] Quantification of dopamine transporters in the mouse brain using ultra-high resolution single-photon emission tomography
    Acton, PD
    Choi, SR
    Plössl, K
    Kung, HF
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (05) : 691 - 698
  • [6] Ultra-high resolution single photon emission tomography imaging of dopamine transporters in the mouse brain
    Acton, P
    Choi, SR
    Plossl, K
    Kung, H
    [J]. NEUROIMAGE, 2002, 16 (03) : S36 - S36
  • [7] Spatial resolution of pinhole single photon emission computed tomography imaging
    Dai Qiu-Sheng
    Qi Yu-Jin
    [J]. ACTA PHYSICA SINICA, 2010, 59 (02) : 1357 - 1365
  • [8] SMALL ANIMAL IMAGING WITH PINHOLE SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    STRAND, SE
    IVANOVIC, M
    ERLANDSSON, K
    FRANCESCHI, D
    BUTTON, T
    SJOGREN, K
    WEBER, DA
    [J]. CANCER, 1994, 73 (03) : 981 - 984
  • [9] Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice
    Wu, MC
    Gao, DW
    Sievers, RE
    Lee, RJ
    Hasegawa, BH
    Dae, MW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (03) : 576 - 582
  • [10] SINGLE-PHOTON EMISSION TOMOGRAPHY WITH A 12-PINHOLE COLLIMATOR
    HASEGAWA, B
    KIRCH, D
    STERN, D
    ADAMS, M
    SKLAR, J
    JOHNSON, T
    STEELE, P
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1982, 23 (07) : 606 - 612