Tissue segmentation-based electron density mapping for MR-only radiotherapy treatment planning of brain using conventional T1-weighted MR images

被引:6
|
作者
Yu, Huan [1 ]
Oliver, Michael [1 ]
Leszczynski, Konrad [1 ]
Lee, Young [2 ,3 ]
Karam, Irene [3 ,4 ]
Sahgal, Arjun [3 ,4 ]
机构
[1] Lakehead Univ, Dept Med Phys, Fac Med,Northeast Canc Ctr, Hlth Sci North,Med Sci Div,Northern Ontario Sch M, Sudbury, ON, Canada
[2] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Dept Med Phys, Toronto, ON, Canada
[3] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[4] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Dept Radiat Oncol, Toronto, ON, Canada
来源
关键词
brain; MR pseudo CT; MR synthetic CT; MR-linac; MR-only treatment planning; PSEUDO-CT; REGISTRATION; SIMULATION; HEAD; GENERATION; SEQUENCES; ACCURACY; NECK;
D O I
10.1002/acm2.12654
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Magnetic resonance imaging (MRI) is the primary modality for targeting brain tumors in radiotherapy treatment planning (RTP). MRI is not directly used for dose calculation since image voxel intensities of MRI are not associated with EDs of tissues as those of computed tomography (CT). The purpose of the present study is to develop and evaluate a tissue segmentation-based method to generate a synthetic-CT (sCT) by mapping EDs to corresponding tissues using only T1-weighted MR images for MR-only RTP. Methods Air regions were contoured in several slices. Then, air, bone, brain, cerebrospinal fluid (CSF), and other soft tissues were automatically segmented with an in-house algorithm based on edge detection and anatomical information and relative intensity distribution. The intensities of voxels in each segmented tissue were mapped into their CT number range to generate a sCT. Twenty-five stereotactic radiosurgery and stereotactic ablative radiotherapy patients' T1-weighted MRI and coregistered CT images from two centers were retrospectively evaluated. The CT was used as ground truth. Distances between bone contours of the external skull of sCT and CT were measured. The mean error (ME) and mean absolute error (MAE) of electron density represented by standardized CT number was calculated in HU. Results The average distance between the contour of the external skull in sCT and the contour in coregistered CT is 1.0 +/- 0.2 mm (mean +/- 1SD). The ME and MAE differences for air, soft tissue and whole body voxels within external body contours are -4 HU/24 HU, 2 HU/26 HU, and -2 HU/125 HU, respectively. Conclusions A MR-sCT generation technique was developed based on tissue segmentation and voxel-based tissue ED mapping. The generated sCT is comparable to real CT in terms of anatomical position of tissues and similarity to the ED assignment. This method provides a feasible method to generate sCT for MR-only radiotherapy treatment planning.
引用
收藏
页码:11 / 20
页数:10
相关论文
共 50 条
  • [31] Automated segmentation of brain metastases in T1-weighted contrast-enhanced MR images pre and post stereotactic radiosurgery
    Kanakarajan, Hemalatha
    De Baene, Wouter
    Hanssens, Patrick
    Sitskoorn, Margriet
    BMC MEDICAL IMAGING, 2025, 25 (01):
  • [32] An Enhanced Fuzzy Segmentation Framework for extracting white matter from T1-weighted MR images
    Vinurajkumar, S.
    Anandhavelu, S.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 71
  • [33] Knowledge-based Segmentation of Attenuation-relevant Regions of the Head in T1-weighted MR Images for Attenuation Correction in MR/PET Systems
    Wagenknecht, Gudrun
    Kops, Elena Rota
    Tellmann, Lutz
    Herzog, Hans
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3338 - +
  • [34] In-vivo dosimetric evaluation of an atlas based labeling technique using MR DIXON for MR-only RT treatment planning
    Frantzen-Steneker, M.
    Helle, M.
    Schulz, H.
    Renisch, S.
    Schadewaldt, N.
    Wolf, A.
    Rozendaal, R.
    Van Kranen, S.
    Alpay, E.
    Van der Heide, U.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S104 - S104
  • [35] Robustness of Conditional Generative Adversarial Networks in Generating Head and Neck Synthetic CT Images for MR-Only Radiotherapy Treatment Planning
    Klages, P.
    Benslimane, I.
    Riyahi, S.
    Jiang, J.
    Hunt, M.
    Deasy, J.
    Veeraraghavan, H.
    Tyagi, N.
    MEDICAL PHYSICS, 2019, 46 (06) : E295 - E296
  • [36] Brain tissue integrity mapping in adults with obstructive sleep apnea using T1-weighted and T2-weighted images
    Roy, Bhaswati
    Sahib, Ashish K. K.
    Kang, Daniel
    Aysola, Ravi S. S.
    Kumar, Rajesh
    THERAPEUTIC ADVANCES IN NEUROLOGICAL DISORDERS, 2022, 15
  • [37] Brain Segmentation Performance using T1-weighted Images versus T1 Maps
    Li, Xiaoxing
    Wyatt, Christopher
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [38] Automatic Extraction of the Midsagittal Surface from T1-Weighted MR Brain Images Using a Multiscale Filtering Approach
    Frasca, Fernando N.
    Poloni, Katia M.
    Ferrari, Ricardo J.
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS, ICCSA 2021, PT II, 2021, 12950 : 131 - 146
  • [39] Automated Classification of Types of Brain Tumor in T1-weighted MR Images: A Thorough Comparative Study
    Qi, Lim Jia
    Alias, Norma
    Johar, Farhana
    PROCEEDINGS OF THE 27TH NATIONAL SYMPOSIUM ON MATHEMATICAL SCIENCES (SKSM27), 2020, 2266
  • [40] DIAGNOSIS OF PELVIC ENDOMETRIOSIS - FAT-SUPPRESSED T1-WEIGHTED VS CONVENTIONAL MR-IMAGES
    HA, HK
    LIM, YT
    KIM, HS
    SUH, TS
    SONG, HH
    KIM, SJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) : 127 - 131