Detection of occult left ventricular dysfunction in patients without prior clinical history of myocardial infarction by technetium-99m sestamibi myocardial perfusion gated single-photon emission computed tomography

被引:0
|
作者
Yao, SS
Nichols, K
DePuey, EG
Rozanski, A
机构
[1] St Lukes Roosevelt Hosp, Div Cardiol, New York, NY 10019 USA
[2] Columbia Univ Coll Phys & Surg, New York, NY 10032 USA
关键词
Tc-99m myocardial perfusion gated single-photon; emission computed tomography; left ventricular volume; left ventricular ejection fraction;
D O I
10.1002/clc.4960250907
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In the absence of a prior history of myocardial infarction (MI), left ventricular (LV) dysfunction is commonly due to hypertension, valvular heart disease, or hibernating myocardium. Hypothesis: Since technetium-99m sestamibi gated single-photon emission computed tomography (SPECT) may be used to determine both stress/rest myocardial perfusion and resting LV function, we attempted to evaluate the ability of gated SPECT imaging to detect occult LV dysfunction. Methods: We evaluated the ability of this technique to detect occult LV dysfunction among 179 patients without history MI and angiographically documented coronary artery disease (CAD). All patients underwent both gated SPECT and cardiac catheterization within a 6-month time period. Left ventricular volume and ejection fraction (EF) values were determined according to a previously validated technique using Simpson's rule. Normal limit values for LV volumes and EF were derived from a control population of 93 patients with normal coronary angiograms. Results: Based on normal limit-derived criteria, 15% of the CAD study cohort had occult LV dysfunction (> 2 standard deviations below gender-specific normal limit means for LVEF). Mean LV end-diastolic volume index (EDVi) was significantly increased (p < 0.05) and LVEF decreased (p < 0.05) in patients with triple-vessel CAD. End-diastolic volume index was also increased in the cohort of patients with both hypertension and LV hypertrophy (LVH) (p < 0.05). However, multivariate logistic regression analysis revealed that only CAD extent, but not hypertension or LVH, was a significant predictor of occult LV dysfunction (p = 0.009). Conclusion: Occult LV dysfunction can be detected in patients with CAD by gating technetium-99m sestamibi SPECT studies, and its presence may signify the presence of extensive CAD.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [31] Technetium-99m tetrofosmin myocardial perfusion single photon emission computed tomography in syndrome X - A preliminary report
    Hsu, HB
    Shiau, YC
    Kao, A
    Lin, CC
    Lee, CC
    JAPANESE HEART JOURNAL, 2003, 44 (02): : 153 - 162
  • [32] Nitrate administration to enhance the detection of myocardial viability by technetium-99m tetrofosmin single-photon emission tomography
    Flotats, A
    Carrio, I
    Estorch, M
    Berna, L
    Catafau, AM
    Mari, C
    Ballester, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (07): : 767 - 773
  • [33] Nitrate administration to enhance the detection of myocardial viability by technetium-99m tetrofosmin single-photon emission tomography
    Flotats A.
    Carrió I.
    Estorch M.
    Bernà L.
    Catafau A.M.
    Marí C.
    Ballester M.
    European Journal of Nuclear Medicine, 1997, 24 (7) : 767 - 773
  • [34] The prognostic value of stress technetium-99m sestamibi gated single photon emission computed tomography in patients with dilated cardiomyopathy
    Gemayel, CY
    Verma, VK
    Velusamy, M
    Mann, A
    Katten, D
    Ahlberg, A
    Mather, J
    Heller, GV
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 381A - 382A
  • [35] The role of technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography (SPECT) in the detection of cardiovascular involvement in systemic lupus erythematosus patients with non-specific chest complaints
    Sun, SS
    Shiau, YC
    Tsai, SC
    Lin, CC
    Kao, A
    Lee, CC
    RHEUMATOLOGY, 2001, 40 (10) : 1106 - 1111
  • [36] A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma
    Kostakoglu L.
    Uysal U.
    Özyar E.
    Demirkazik F.B.
    Hayran M.
    Atahan L.
    Bekdik C.F.
    European Journal of Nuclear Medicine, 1997, 24 (6) : 621 - 628
  • [37] A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma
    Kostakoglu, L
    Uysal, U
    Ozyar, E
    Demirkazik, FB
    Hayran, M
    Atahan, L
    Bekdik, CF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (06): : 621 - 628
  • [38] Clinical role of technetium-99m sestamibi single-photon emission tomography in evaluating pretreated patients with brain tumours
    Maffioli, L
    Gasparini, M
    Chiti, A
    Gramaglia, A
    Mongioj, V
    Pozzi, A
    Bombardieri, E
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (03): : 308 - 311
  • [39] Prognostic significance of fixed perfusion abnormalities on stress technetium-99m Sestamibi single-photon emission computed tomography in patients without known coronary artery disease
    Elhendy, A
    Schinkel, AFL
    van Donburg, RT
    Bax, JJ
    Poldermans, D
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (10): : 1165 - 1170
  • [40] Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging
    Smanio, PEP
    Watson, DD
    Segalla, DL
    Vinson, EL
    Smith, WH
    Beller, GA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (07) : 1687 - 1692