Non-invasive intracranial pressure assessment using shear-wave elastography in neuro-critical care patients

被引:5
|
作者
Xu, Guohui [1 ]
Wu, Xuehai [2 ]
Yu, Jian [2 ]
Ding, Hong [1 ]
Ni, Zilong [3 ]
Wang, Yong [1 ]
机构
[1] Fudan Univ, Dept Ultrason Med, Affiliated Huashan Hosp, 12 Middle Wulumuqi Rd, Shanghai 200040, Peoples R China
[2] Fudan Univ, Dept Neurosugery, Affiliated Huashan Hosp, 12 Middle Wulumuqi Rd, Shanghai 200040, Peoples R China
[3] Simens Healthineers, Dept Ultrasound Clin Market, 399 West Haiyang Rd, Shanghai 200126, Peoples R China
关键词
Intracranial pressure; Optic nerve; Optic nerve sheath; Optic nerve sheath diameter; Shear-wave elastography; Ultrasound; OPTIC-NERVE SHEATH; TRAUMATIC BRAIN-INJURY; DIAMETER; ULTRASOUND; PRINCIPLES; ACCURACY; STRAIN;
D O I
10.1016/j.jocn.2022.03.011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To determine if Young's modulus of the optic nerve (ON) structure as measured by shear-wave elastography can suggest changes in intracranial pressure (ICP) in neuro-critical care patients. Materials and methods: Thirty-one healthy volunteers and twenty-two neuro-critical care patients were enrolled. ON sheath (ONS) diameter (ONSD) values and Young's modulus measurements of volunteers were collected in a calm state and during a Valsalva maneuver (VM). Ultrasound measurements and ICP values of patients were collected on operation day and at 24 and 48 h after the operation; measurements were thereafter assigned to three groups: severely elevated (ICP greater than 22 mmHg), mildly elevated (ICP = 14-22 mmHg), and normal (ICP <= 13 mmHg). Results: ONSD and Young's modulus for the ON and ONS of volunteers during VM were higher than those in the calm state (all P < 0.001). In contrast to ONSD, Young's modulus for ON and ONS did not correlate with age, body mass index, or sex. The best cutoff values of Young's modulus for ON for predicting elevated and severely elevated ICP were 16.67 kPa and 22.74 kPa, respectively. Accordingly, the sensitivity values were 96.7% and 88.9%, and the specificity values were 86.1% and 73.7%, which had the same diagnostic performance as ONSD. Conclusion: Young's modulus of the ON accurately reflects changes in ICP. It is not confounded by age, sex, or body mass index compared to ONSD.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 50 条
  • [11] Prospective comparison of shear-wave elastography, CAP and conventional ultrasound for non-invasive detection and grading of steatosis
    Ronot, M.
    Rautou, P-E.
    Di Burgio, M.
    Payence, A.
    Bedossa, P.
    Paradis, V.
    Francoz, C.
    Nekachtali, O.
    Durand, F.
    Vilgrain, V.
    Castera, L.
    JOURNAL OF HEPATOLOGY, 2017, 66 (01) : S667 - S668
  • [12] NON-INVASIVE QUANTITATIVE ASSESSMENT OF MUSCLE FORCE BASED ON ULTRASONIC SHEAR WAVE ELASTOGRAPHY
    Liu, Jing
    Qian, Zhihui
    Wang, Kunyang
    Wu, Jianan
    Jabran, Ali
    Ren, Luquan
    Ren, Lei
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (02): : 440 - 451
  • [13] Redox Homeostasis and Non-Invasive Assessment of Significant Liver Fibrosis by Shear Wave Elastography
    Egresi, Anna
    Anna, Blazovics
    Lengyel, Gabriella
    Toth, Adrienn Greta
    Csongrady, Barbara
    Jakab, Zsuzsanna
    Hagymasi, Krisztina
    DIAGNOSTICS, 2024, 14 (17)
  • [14] Non-invasive assessment of intracranial pressure dynamics
    Aaslid, R.
    CEREBROVASCULAR DISEASES, 2013, 35 : 6 - 6
  • [15] Non-invasive assessment of liver fibrosis using two-dimensional shear wave elastography in patients with autoimmune liver diseases
    Zeng, Jie
    Huang, Ze-Ping
    Zheng, Jian
    Wu, Tao
    Zheng, Rong-Qin
    WORLD JOURNAL OF GASTROENTEROLOGY, 2017, 23 (26) : 4839 - 4846
  • [16] PROSPECTIVE COMPARISON OF SPLEEN STIFFNESS MEASURED BY MAGNETIC RESONANCE ELASTOGRAPHY VERSUS SHEAR-WAVE ELASTOGRAPHY FOR NON-INVASIVE ASSESSMENT OF CLINICALLY SIGNIFICANT AND SEVERE PORTAL HYPERTENSION
    Chang, Jason Pik Eu
    Low, Albert Su-Chong
    Ooi, Chin-Chin
    Cheng, Lionel Tim-Ee
    Tay, Mei-Fang
    Lau, Denise S.
    Abu Bakar, Rafidah B.
    Lim, Sze-Ying
    Gogna, Apoorva
    Too, Chow-Wei
    Ying, Hao
    Tan, Hiang-Keat
    Tan, Chee-Kiat
    HEPATOLOGY, 2019, 70 : 495A - 496A
  • [17] Assessment of the optic nerve using strain and shear-wave elastography in patients with pseudotumour cerebri
    Asal, N.
    Inal, M.
    Sahan, M. H.
    Say, B.
    CLINICAL RADIOLOGY, 2020, 75 (08) : 629 - 635
  • [18] COMPARATIVE STUDY BETWEEN THE DIAGNOSTIC PERFORMANCE OF POINT AND 2-D SHEAR-WAVE ELASTOGRAPHY FOR THE NON-INVASIVE ASSESSMENT OF LIVER FIBROSIS IN PATIENTS WITH CHRONIC HEPATITIS C USING TRANSIENT ELASTOGRAPHY AS REFERENCE
    Baldea, Victor
    Sporea, Ioan
    Lupusoru, Raluca
    Bende, Felix
    Mare, Ruxandra
    Popescu, Alina
    Sirli, Roxana
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (11): : 2979 - 2988
  • [19] Non-invasive assessment of human multifidus muscle stiffness using ultrasound shear wave elastography: A feasibility study
    Moreau, Baptiste
    Vergari, Claudio
    Gad, Hisham
    Sandoz, Baptiste
    Skalli, Wafa
    Laporte, Sebastien
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (08) : 809 - 814
  • [20] Feasibility of Non-Invasive Method of Diagnosing Pancreatic Fibrosis Using Shear Wave Elastography
    Kuwahara, Takamichi
    Hirooka, Yoshiki
    Kawashima, Hiroki
    Ohno, Eizaburo
    Sugimoto, Hiroyuki
    Hayashi, Daijuro
    Morishima, Tomomasa
    Kawai, Manabu
    Suhara, Hiroki
    Takeyama, Tomoaki
    Yamamura, Takeshi
    Furukawa, Kazuhiro
    Funasaka, Kohei
    Nakamura, Masanao
    Miyahara, Ryoji
    Goto, Hidemi
    GASTROENTEROLOGY, 2015, 148 (04) : S929 - S929