Bone stress for a mini-implant close to the roots of adjacent teeth-3D finite element analysis

被引:59
|
作者
Motoyoshi, M. [1 ]
Ueno, S. [1 ]
Okazaki, K. [1 ]
Shimizu, N. [1 ]
机构
[1] Nihon Univ, Sch Dent, Dept Orthodont, Div Clin Res,Dent Res Ctr,Chiyoda Ku, Tokyo 1018310, Japan
关键词
temporary anchorage devices; anchorage; finite element method; bone resorption; POSTERIOR REGION; PLACEMENT TORQUE; TITANIUM SCREWS; ANCHORAGE; THICKNESS; STABILITY; FAILURE;
D O I
10.1016/j.ijom.2009.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to evaluate stress in the bone when an orthodontic mini-implant is close to the roots of adjacent teeth using finite element models (FEMs), and to investigate the causes of the high implant failure rate in the mandible. Four FEMs were used: the implant touches nothing; the implant touches the surface of the periodontal membrane; part of the screw thread is embedded in the periodontal membrane; and the implant touches the root. The effect of cortical bone thickness was evaluated using values of 1, 2 and 3 mm. Maximum stress value and stress distribution on the bone elements was determined. Maximum stress on the bone increased when the mini-implant was close to the root. When the implant touched the root, stress increased to 140 MPa or more, and bone resorption could be predicted. Stress was higher for a cortical bone thickness of 2 mm than for other thicknesses. Cortical bone 2 mm thick had a higher risk for bone resorption. A mandible with an average cortical bone thickness of 2 mm may have a higher risk for implant loosening than a maxilla with the same degree of root proximity, which may be related to the lower success rate in the mandible.
引用
收藏
页码:363 / 368
页数:6
相关论文
共 50 条
  • [41] Effect of platform switching on peri-implant bone: A 3D finite element analysis
    Aslam, Ayesha
    Hassan, Syed Hammad
    Aslam, Hammad Mudasser
    Khan, Danish Azeem
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (06): : 935 - 940
  • [42] Three-dimensional finite element analysis of the deformation of the human mandible: a preliminary study from the perspective of orthodontic mini-implant stability
    Baek, Sun-Hye
    Cha, Hyun-Suk
    Cha, Jung-Yul
    Moon, Yoon-Shik
    Sung, Sang-Jin
    KOREAN JOURNAL OF ORTHODONTICS, 2012, 42 (04) : 159 - 168
  • [43] Influence of Implant/Abutment Connection on Stress Distribution to Implant-Surrounding Bone: A Finite Element Analysis
    Hanaoka, Marcia
    Alexandre Gehrke, Sergio
    Mardegan, Fabio
    Gennari, Cesar Roberto
    Taschieri, Silvio
    Del Fabbro, Massimo
    Corbella, Stefano
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (07): : 565 - 571
  • [44] Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis
    Zhang, Wen-tao
    Cheng, Kang-jie
    Liu, Yun-feng
    Wang, Russell
    Chen, Yun-fang
    Ding, Yu-de
    Yang, Fan
    Wang, Lin-hong
    BMC ORAL HEALTH, 2022, 22 (01)
  • [45] Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis
    Wen-tao Zhang
    Kang-jie Cheng
    Yun-feng Liu
    Russell Wang
    Yun-fang Chen
    Yu-de Ding
    Fan Yang
    Lin-hong Wang
    BMC Oral Health, 22
  • [46] The effect of diameter, length and elastic modulus of a dental implant on stress and strain levels in peri-implant bone: A 3D finite element analysis
    Robau-Porrua, Amanda
    Perez-Rodriguez, Yoan
    Soris-Rodriguez, Laura M.
    Perez-Acosta, Osmel
    Gonzalez, Jesus E.
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 30 (5-6) : 541 - 558
  • [47] Evaluation of Stress Distribution and Force in External Hexagonal Implant: A 3-D Finite Element Analysis
    Bandela, Vinod
    Basany, Ram
    Nagarajappa, Anil Kumar
    Basha, Sakeenabi
    Kanaparthi, Saraswathi
    Ganji, Kiran Kumar
    Patil, Santosh
    Gudipaneni, Ravi Kumar
    Mohammed, Ghazi Sghaireen
    Alam, Mohammad Khursheed
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (19)
  • [48] Effect of Short Dental Implant Material on Bone Stress: An In Vitro Finite Element Analysis
    Al Qahtani, Waleed M. S.
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2022, 12 (09) : 1781 - 1786
  • [49] The effect of thread geometry on the stress distribution in the bone around implant: 2-D finite element analysis.
    Salimee, P
    Thanapalin, T
    Dechaumphai, P
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 648 - 648
  • [50] The effect of periapical bone defects on stress distribution in teeth with periapical periodontitis: a finite element analysis
    Chen, Shuomin
    Ye, Zhangyan
    Hong, Xinhua
    Chen, Liang
    Wu, Linmei
    Wang, Yilin
    Chen, Yuge
    Wu, Menghan
    Wang, Jun
    Zhang, Qinhui
    Wu, Yutian
    Sun, Xiaoyu
    Ding, Xi
    Huang, Shengbin
    Zhao, Shufan
    BMC ORAL HEALTH, 2023, 23 (01)