Continuous monitoring of cardiac output from TCG signals

被引:0
|
作者
Keenan, DB [1 ]
机构
[1] VivoMetrics Inc, Sugitani, Toyama 93001, Japan
关键词
thoracocardiograph; plethysmographic; SV; CO; accelerometer; adaptive filtering; spectral subtraction; LMS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous measurement of cardiac output (CO) is an important and difficult measure to obtain in an ambulatory environment. A novel ambulatory monitoring system (LifeShirt. VivoMetrics. Inc., Ventura, CA. USA) with three Inductive Plethysinographic (IP) sensors embedded in a garment, enables continuous monitoring of respiration from the ribcage and abdomen areas, and captures thoracocardiograph (TCG) signals from the thorax at the level of the left ventricle. This TCG signal provides a non-invasive measure of the volumetric contractions of the heart. The raw TCG signal must undergo extensive signal processing and digital filtering to extract a volume Curve similar to the ventricular volume curve obtained through echocardiography. Typically the respiratory component has an amplitude of over twenty times that of the stroke volume curve. This investigation compares various signal processing algorithms such as spectral subtraction and adaptive filtering to separate these 2 components, which can occupy the came frequency band. These algorithms make use of the ribcage and abdominal signals to predict the respiratory component within the TCG signal. A dual axis accelerometer that measures posture and levels of activity aids filtering movement artifact. With the addition of a single lead ECG, ensemble averaging is used to smooth artifact in the signal. and CO may be obtained by including a heart rate measure. Additional measures can be erived including left ventricular systolic time intervals such as Pre-ejection period,. Peak ejection rate and time to peak ejection rate. The results show that increases and decreases in SV and CO can be measured over time.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 50 条
  • [21] CONTINUOUS CARDIAC-OUTPUT MONITORING BY ANALYSIS OF THE PULSE CONTOUR
    DOSSANTOS, P
    COSTE, P
    BERNADET, P
    DURRIEUJAIS, C
    BESSE, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1994, 87 (01): : 65 - 74
  • [22] Continuous Thermodilution Cardiac Output Monitoring During Therapeutic Hypothermia
    Bendjelid, Karim
    ANESTHESIA AND ANALGESIA, 2011, 112 (01): : 250 - 251
  • [23] Continuous cardiac output and mixed venous oxygen saturation monitoring
    Cariou, A
    Monchi, M
    Dhainaut, JF
    JOURNAL OF CRITICAL CARE, 1998, 13 (04) : 198 - 213
  • [24] Continuous Cardiac Output Monitoring by Analysis of Peripheral Blood Pressure
    Lee, Kichang
    Arai, Tatsuya
    Cohen, Richard J.
    FASEB JOURNAL, 2008, 22
  • [25] CONTINUOUS CARDIAC OUTPUT MONITORING IN EXERCISING HORSES USING PULSECO®
    Jesty, S. A.
    Fletcher, D. J.
    Mitchell, L. M.
    Yaple, C.
    Soderholm, L. V.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (03) : 690 - 690
  • [26] Continuous cardiac output monitoring -: further applications of the thermodilution principle
    Böttiger, BW
    INTENSIVE CARE MEDICINE, 1999, 25 (02) : 131 - 133
  • [27] Continuous cardiac output monitoring – further applications of the thermodilution principle
    B. W. Böttiger
    Intensive Care Medicine, 1999, 25 : 131 - 133
  • [28] Continuous monitoring of cardiac output during pneumoperitoneum by esophagal Doppler
    F Zveibil
    S Yvri
    A Schlepak
    NM Akhoul
    Critical Care, 7 (Suppl 2):
  • [29] Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement
    Pittman, J
    Bar-Yosef, S
    SumPing, J
    Sherwood, M
    Mark, J
    CRITICAL CARE MEDICINE, 2005, 33 (09) : 2015 - 2021
  • [30] CONTINUOUS CARDIAC-OUTPUT MONITORING BY PULSE CONTOUR DURING CARDIAC-SURGERY
    JANSEN, JRC
    WESSELING, KH
    SETTELS, JJ
    SCHREUDER, JJ
    EUROPEAN HEART JOURNAL, 1990, 11 : 26 - 32