Continuous monitoring of cardiac output from TCG signals

被引:0
|
作者
Keenan, DB [1 ]
机构
[1] VivoMetrics Inc, Sugitani, Toyama 93001, Japan
关键词
thoracocardiograph; plethysmographic; SV; CO; accelerometer; adaptive filtering; spectral subtraction; LMS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous measurement of cardiac output (CO) is an important and difficult measure to obtain in an ambulatory environment. A novel ambulatory monitoring system (LifeShirt. VivoMetrics. Inc., Ventura, CA. USA) with three Inductive Plethysinographic (IP) sensors embedded in a garment, enables continuous monitoring of respiration from the ribcage and abdomen areas, and captures thoracocardiograph (TCG) signals from the thorax at the level of the left ventricle. This TCG signal provides a non-invasive measure of the volumetric contractions of the heart. The raw TCG signal must undergo extensive signal processing and digital filtering to extract a volume Curve similar to the ventricular volume curve obtained through echocardiography. Typically the respiratory component has an amplitude of over twenty times that of the stroke volume curve. This investigation compares various signal processing algorithms such as spectral subtraction and adaptive filtering to separate these 2 components, which can occupy the came frequency band. These algorithms make use of the ribcage and abdominal signals to predict the respiratory component within the TCG signal. A dual axis accelerometer that measures posture and levels of activity aids filtering movement artifact. With the addition of a single lead ECG, ensemble averaging is used to smooth artifact in the signal. and CO may be obtained by including a heart rate measure. Additional measures can be erived including left ventricular systolic time intervals such as Pre-ejection period,. Peak ejection rate and time to peak ejection rate. The results show that increases and decreases in SV and CO can be measured over time.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 50 条
  • [1] Continuous cardiac output monitoring: Really continuous?
    Lambermont, Bernard
    CRITICAL CARE MEDICINE, 2007, 35 (10) : 2469 - 2470
  • [2] CONTINUOUS MONITORING OF CARDIAC-OUTPUT
    MACKAY, RS
    HECHTMAN, HB
    BIOTELEMETRY, 1974, 1 (01) : 21 - 30
  • [3] Continuous cardiac output monitoring system
    S. C. Tjin
    Y. C. Ho
    Y. -Z. Lam
    J. Hao
    B. K. Ng
    Medical and Biological Engineering and Computing, 2001, 39 : 101 - 104
  • [4] CONTINUOUS MONITORING OF CARDIAC-OUTPUT
    SAADJIAN, A
    TORRESANI, J
    QUERCY, JF
    AMICHOT, JL
    JOUVE, A
    LACROIX, Y
    NOUVELLE PRESSE MEDICALE, 1972, 1 (32): : 2113 - +
  • [5] Continuous cardiac output monitoring system
    Tjin, SC
    Ho, YC
    Lam, YZ
    Hao, J
    Ng, BK
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (01) : 101 - 104
  • [6] Continuous cardiac output monitoring: Really continuous? Reply
    Cooper, Edward S.
    Muir, William W.
    CRITICAL CARE MEDICINE, 2007, 35 (10) : 2470 - 2470
  • [7] CONTINUOUS CARDIAC-OUTPUT MONITORING IN POSTCARDIOTOMY LOW OUTPUT SYNDROME
    POELAERT, J
    ROOSENS, C
    FOUBERT, L
    DESOMER, F
    CAES, F
    COLARDYN, FA
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (03) : 348 - 349
  • [8] New generation continuous cardiac output monitoring from carbon dioxide elimination
    Peyton, Philip J.
    Wallin, Mats
    Hallback, Magnus
    BMC ANESTHESIOLOGY, 2019, 19 (1)
  • [9] CONTINUOUS CARDIAC-OUTPUT MONITORING BY THE FICK METHOD
    BAXLEY, WA
    CAVENDER, JB
    KNOBLOCK, J
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 28 (01): : 89 - 92
  • [10] Continuous cardiac output monitoring by blood pressure analysis
    van Lieshout, Johannes J.
    Jansen, Jos R. C.
    JOURNAL OF APPLIED PHYSIOLOGY, 2007, 102 (02) : 826 - 826