Chemiluminescence determination of moxifloxacin in pharmaceutical and biological samples based on its enhancing effect of the luminol-ferricyanide system using a microfluidic chip

被引:7
|
作者
Suh, Yeoun Suk [1 ]
Kamruzzaman, Mohammad [1 ]
Alam, Al-Mahmnur [1 ]
Lee, Sang Hak [1 ]
Kim, Young Ho [2 ]
Kim, Gyu-Man [3 ]
Trung Dung Dang [4 ]
机构
[1] Kyungpook Natl Univ, Dept Chem, Taegu 702701, South Korea
[2] Kyungpook Natl Univ, Res Inst Adv Energy Technol, Taegu 702701, South Korea
[3] Kyungpook Natl Univ, Sch Mech Engn, Taegu 702701, South Korea
[4] Yeungnam Univ, Sch Mech Engn, Gyeongbuk 712749, South Korea
关键词
microfluidic chip; moxifloxacin; chemiluminescence; luminol; ferricyanide; PERFORMANCE LIQUID-CHROMATOGRAPHY; IN-VITRO ACTIVITY; CAPILLARY-ELECTROPHORESIS; HUMAN PLASMA; INJECTION-ANALYSIS; HUMAN URINE; BAY; 12-8039; TABLETS; LEVOFLOXACIN; SERUM;
D O I
10.1002/bio.2536
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive determination of a synthetic fluoroquinolone antibacterial agent, moxifloxacin (MOX), by an enhanced chemiluminescence (CL) method using a microfluidic chip is described. The microfluidic chip was fabricated by a soft-lithographic procedure using polydimethyl siloxane (PDMS). The fabricated PDMS microfluidic chip had three-inlet microchannels for introducing the sample, chemiluminescent reagent and oxidant, and a 500 mu m wide, 250 mu m deep and 82mm long microchannel. An enhanced CL system, luminol-ferricyanide, was adopted to analyze the MOX concentration in a sample solution. CL light was emitted continuously after mixing luminol and ferricyanide in the presence of MOX on the PDMS microfluidic chip. The amount of MOX in the luminol-ferricyanide system influenced the intensity of the CL light. The linear range of MOX concentration was 0.14-55.0ng/mL with a correlation coefficient of 0.9992. The limit of detection (LOD) and limit of quantification (LOQ) were 0.06 and 0.2ng/mL respectively. The presented method afforded good reproducibility, with a relative standard deviation (RSD) of 1.05% for 10ng/mL of MOX, and has been successfully applied for the determination of MOX in pharmaceutical and biological samples. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 50 条
  • [41] A general chemiluminescence method for the determination of surfactants based on its quenching effect on the luminol-NaIO4-cyclodextrin reaction
    Cao, ZJ
    Lau, CW
    Lu, JZ
    ANALYST, 2004, 129 (12) : 1262 - 1266
  • [42] Determination of cytochrome c based on its enhancing effect on the electrogenerated chemiluminescence of carbon quantum dots
    YongPing Dong
    Ying Peng
    Jiao Wang
    ChengMing Wang
    Microchimica Acta, 2017, 184 : 2089 - 2095
  • [43] Determination of cytochrome c based on its enhancing effect on the electrogenerated chemiluminescence of carbon quantum dots
    Dong, YongPing
    Peng, Ying
    Wang, Jiao
    Wang, ChengMing
    MICROCHIMICA ACTA, 2017, 184 (07) : 2089 - 2095
  • [44] Flow-based determination of methionine in pharmaceutical formulations exploiting TGA-capped CdTe quantum dots for enhancing the luminol-KIO4 chemiluminescence
    Zhou, Min
    Wang, Ailian
    Li, Cong
    Luo, Xiaowei
    Ma, Yongjun
    JOURNAL OF LUMINESCENCE, 2017, 183 : 206 - 211
  • [45] Determination of fluoxetine in pharmaceutical preparations and biological samples using potentiometric sensors based on polymeric membranes
    Arvand, M.
    Rad, N. Ahmadi
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (02) : 183 - 188
  • [46] Determination of fluoxetine in pharmaceutical preparations and biological samples using potentiometric sensors based on polymeric membranes
    M. Arvand
    N. Ahmadi Rad
    Journal of Analytical Chemistry, 2013, 68 : 183 - 188
  • [47] Flow-injection chemiluminescence determination of acetylsalicylic acid based on its enhancing effect on the lucigenin-hydrogen peroxide system
    Wabaidur, S. M.
    Alam, S. M.
    Alothman, Z. A.
    Eldesoky, Gaber
    LUMINESCENCE, 2014, 29 (06) : 684 - 688
  • [48] A miniaturized chemiluminescence detection system for a microfluidic paper-based analytical device and its application to the determination of chromium(III)
    Alahmad, Waleed
    Uraisin, Kanchana
    Nacapricha, Duangjai
    Kaneta, Takashi
    ANALYTICAL METHODS, 2016, 8 (27) : 5414 - 5420
  • [49] Flow-injection chemiluminescence method for the determination of moxifloxacin in pharmaceutical tablets and human urine using silver nanoparticles sensitized calcein-KMnO4 system
    Wabaidur, Saikh Mohammad
    Alam, Seikh Mafiz
    Alothman, Zeid A.
    Siddiqui, Masoom Raza
    Naushad, Mu
    Alqadami, Ayoub A.
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2015, 38 (09) : 1803 - 1810
  • [50] Flow-injection chemiluminescence method for the determination of moxifloxacin in pharmaceutical tablets and human urine using silver nanoparticles sensitized calcein–KMnO4 system
    Saikh Mohammad Wabaidur
    Seikh Mafiz Alam
    Zeid A. Alothman
    Masoom Raza Siddiqui
    Mu Naushad
    Ayoub A. Alqadami
    Bioprocess and Biosystems Engineering, 2015, 38 : 1803 - 1810