Patient-specific templates for image-guided intervention-a phantom study

被引:8
|
作者
Venturi, David [1 ]
Glossop, Neil [2 ,3 ]
Bale, Reto [1 ]
机构
[1] Med Univ Innsbruck, Dept Radiol, Intervent Oncol Microinvas Therapy SIP, Anichstr 35, A-6020 Innsbruck, Austria
[2] Queens Univ, Sch Comp, Kingston, ON, Canada
[3] ArciTrax Inc, Toronto, ON, Canada
关键词
Percutaneous; radiofrequency ablation; phantom study; accuracy evaluation; LASER NAVIGATION SYSTEM; RADIOFREQUENCY ABLATION; GUIDANCE-SYSTEM; CT; ACCURACY; PUNCTURE; BIOPSY; LIVER;
D O I
10.1080/13645706.2019.1626251
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To evaluate the in vitro accuracy of a new device and method for simultaneous stereotactic CT-guided punctures. Material and methods: 240 needle paths were planned in 1 mm, 1.5 mm and 3 mm slice thickness with a custom-designed software. The data were transferred to a three-axis tabletop CNC machine that then drilled the hole pattern for the needles into square plastic plates. Kirschner wires were slid through the holes of the two parallel fixed plates to aim at the chosen targets inside the phantom. The accuracy was calculated by taking control CTs and measuring the Euclidean distance and the normal distance between the wire and the entry and target point. Results: The mean Euclidean distance of the wire tip to the target for the 1 mm, 1.5mm and 3 mm slice thickness were 2.5 mm (SD +/- 0.64), 2.71mm (SD +/- 0.78) and 2.8 mm (SD +/- 1.0). The mean normal distance was 1.42 mm (SD +/- 0.65), 1.43mm (SD +/- 0.75) and 1.9 mm (SD +/- 1.1), respectively. Conclusion: The system yields satisfactory accuracy comparable to other image-guided intervention systems. Involuntary movements of the patient need to be taken into account in a clinical setting.
引用
收藏
页码:251 / 260
页数:10
相关论文
共 50 条
  • [31] Explainability and controllability of patient-specific deep learning with attention-based augmentation for markerless image-guided radiotherapy
    Terunuma, Toshiyuki
    Sakae, Takeji
    Hu, Yachao
    Takei, Hideyuki
    Moriya, Shunsuke
    Okumura, Toshiyuki
    Sakurai, Hideyuki
    MEDICAL PHYSICS, 2023, 50 (01) : 480 - 494
  • [32] Image-Guided Patient-Specific Quality Assurance for Multi-Target Single Isocenter Intracranial VMAT Radiosurgery
    Huang, M.
    Brezovich, I.
    Duan, J.
    Wu, X.
    Shen, S.
    Cardan, R.
    Fiveash, J.
    Popple, R.
    MEDICAL PHYSICS, 2015, 42 (06) : 3438 - 3438
  • [33] Image-guided patient-specific optimization of catheter placement for convection-enhanced nanoparticle delivery in recurrent glioblastoma
    Wu, Chengyue
    Hormuth, David A.
    Christenson, Chase D.
    Woodall, Ryan T.
    Abdelmalik, Michael R.A.
    Phillips, William T.
    Hughes, Thomas J.R.
    Brenner, Andrew J.
    Yankeelov, Thomas E.
    Computers in Biology and Medicine, 2024, 179
  • [34] Towards Patient-Specific Optimization of Neoadjuvant Treatment Protocols for Breast Cancer Based on Image-Guided Fluid Dynamics
    Wu, Chengyue
    Hormuth, David A.
    Lorenzo, Guillermo
    Jarrett, Angela M.
    Pineda, Federico
    Howard, Frederick M.
    Karczmar, Gregory S.
    Yankeelov, Thomas E.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (11) : 3334 - 3344
  • [35] Image-Guided Bronchoscopy for Comprehensive Lymph Node Staging: A Phantom Study
    Higgins, W. E.
    Kuhlengel, T.
    Ahmad, D.
    Guck, D.
    Chopra, M.
    Shore, D.
    Nuschke, J.
    Bascom, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [36] Distribution Templates of the Fiducial Points in Image-Guided Neurosurgery
    Wang Manning
    Song Zhijian
    NEUROSURGERY, 2010, 66 (03) : 143 - 150
  • [37] Innovation in Image-Guided Spine Intervention
    Murphy, Kieran J.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2011, 15 (02) : 168 - 171
  • [38] Feasibility study of patient-specific surgical templates for the fixation of pedicle screws
    Salako, F
    Aubin, CE
    Fortin, C
    Labelle, H
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 108 (1-2) : 197 - 197
  • [39] Site Specific Image-Guided Radiotherapy (IGRT) Tolerances for Patient Safety
    Wijesooriya, K.
    Seitter, K.
    Dharia, I.
    Read, P.
    Larner, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3498 - 3498
  • [40] Feasibility study of patient-specific surgical templates for the fixation of pedicle screws
    Salako, F
    Aubin, CÉ
    Fortin, C
    Labelle, H
    RESEARCH INTO SPINAL DEFORMITIES 3, 2002, 88 : 419 - 422