Sub-parts-per-billion level detection of NO2 using room-temperature quantum cascade lasers

被引:114
|
作者
Pushkarsky, Michael
Tsekoun, Alexei
Dunayevskiy, Ilya G.
Go, Rowel
Patel, C. Kumar N.
机构
[1] Pranalyt Inc, Santa Monica, CA 90401 USA
[2] Univ Calif Los Angeles, Dept Phys & Astron, Los Angeles, CA 90095 USA
关键词
iR lasers; NO2; spectroscopy; photoacoustic spectroscopy; sub-parts-per-billion detection of gases;
D O I
10.1073/pnas.0604238103
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We report the sub-parts-per-billion-level detection of NO2 using tunable laser-based photoacoustic spectroscopy where the laser radiation is obtained from a room-temperature continuous-wave high-power quantum cascade laser operating in an external grating cavity configuration. The continuously tunable external grating cavity quantum cascade laser produces maximum single-frequency output of approximate to 300 mW tunable over approximate to 350 nm centered at 6.25 mu m.We demonstrate minimum detection level of approximate to 0.5 parts per billion of NO2 in the presence of humidified air.
引用
收藏
页码:10846 / 10849
页数:4
相关论文
共 50 条
  • [21] DETERMINATION OF PERCHLOROETHYLENE IN THE SUB-PARTS-PER-BILLION RANGE IN AMBIENT AIR BY GAS-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION
    SYKES, AL
    WAGONER, DE
    DECKER, CE
    ANALYTICAL CHEMISTRY, 1980, 52 (11) : 1630 - 1633
  • [22] PbSe quantum dots-based chemiresistors for room-temperature NO2 detection
    Li, Min
    Luo, Jingting
    Fu, Chen
    Kan, Hao
    Huang, Zhen
    Huang, Wangman
    Yang, Shuqin
    Zhang, Jianbing
    Tang, Jiang
    Fu, Yongqing
    Li, Honglang
    Liu, Huan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 256 : 1045 - 1056
  • [23] 1.33 THz room-temperature quantum cascade lasers based on ZnMgSe/ZnSe
    Sirkeli, Vadim P.
    Yilmazoglu, Oktay
    Al-Daffaic, Shihab
    Preu, Sascha
    Kueppers, Franko
    Hartnagel, Hans L.
    2017 42ND INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2017,
  • [24] Room-temperature operation of electrically pumped quantum-cascade microcylinder lasers
    Anders, S
    Schrenk, W
    Gornik, E
    Strasser, G
    APPLIED PHYSICS LETTERS, 2002, 80 (22) : 4094 - 4096
  • [25] Ohmic contacts for room-temperature AlGaAs/GaAs quantum cascade lasers (QCL)
    Baranska, Anna
    Szerling, Anna
    Karbownik, Piotr
    Hejduk, Krzysztof
    Bugajski, Maciej
    Laszcz, Adam
    Golaszewska-Malec, Krystyna
    Filipowski, Wojciech
    OPTICA APPLICATA, 2013, 43 (01) : 5 - 15
  • [26] Above room-temperature GaInAs/Al(Ga)AsSb quantum cascade lasers
    Yang, QK
    Manz, C
    Bronner, W
    Köhler, K
    Wagner, J
    PHYSICA STATUS SOLIDI C - CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 3 NO 3, 2006, 3 (03): : 415 - +
  • [27] Room-temperature operation of mid-infrared surfaceplasmon quantum cascade lasers
    Bahriz, M.
    Moreau, V.
    Palomo, J.
    Krysa, A. B.
    Austin, D.
    Cockburn, J. W.
    Roberts, J. S.
    Wilson, L. R.
    Julien, F.
    Colombelli, R.
    PHYSICS OF SEMICONDUCTORS, PTS A AND B, 2007, 893 : 1451 - +
  • [28] Photoacoustic detection of NO2 and N2O using quantum cascade lasers
    J.P. Lima
    H. Vargas
    A. Miklós
    M. Angelmahr
    P. Hess
    Applied Physics B, 2006, 85 : 279 - 284
  • [29] Photoacoustic detection of NO2 and N2O using quantum cascade lasers
    Lima, J. P.
    Vargas, H.
    Miklos, A.
    Angelmahr, M.
    Hess, P.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 279 - 284
  • [30] A calibrated graphene-based chemi-sensor for sub parts-per-million NO2 detection operating at room temperature
    Ricciardella, F.
    Massera, E.
    Polichetti, T.
    Miglietta, M. L.
    Di Francia, G.
    APPLIED PHYSICS LETTERS, 2014, 104 (18)