Quantifiable and feasible estrus detection using the ultrasonic sensor array and digital infrared thermography

被引:12
|
作者
Lee, Ji Hwan [1 ]
Lee, Dong Hoon [2 ]
Yun, Won [1 ]
Oh, Han Jin [1 ]
An, Ji Seon [1 ]
Kim, Young Gwang [1 ]
Kim, Gok Mi [3 ]
Cho, Jin Ho [1 ]
机构
[1] Chungbuk Natl Univ, Div Food & Anim Sci, Cheongju 28644, South Korea
[2] Chungbuk Natl Univ, Dept Biosyst Engn, Cheongju 28644, South Korea
[3] Yonam Coll, Dept Beauty Art, Cheonan 31005, South Korea
关键词
Digital infrared thermography; Estrus; Standing time; Ultrasonic sensor array; Vulvar temperature;
D O I
10.5187/jast.2019.61.3.163
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Detection of estrus is an essential factor as a method of successful breeding in the sow. As increasing the adaption of the information and communication technology (ICT) into swine industry, this study focuses on a possibility and quantification of standing time, vulva and body temperature as methods of estrus detection, comparing each time and temperature in estrus and non-estrus period, and analyzing each success rate of new and existing methods. Ultrasonic sensor array and digital infrared thermography were used to evaluate whether new methods such as standing time and number, and vulva and skin temperature can be replaced, or these methods can be quantifiable in estrus period. Ultrasonic sensor array was installed beside the stall and digital infrared thermography was placed in the rear of sow to collect the dates of sow in estrus and non-estrus period. This study showed total standing time, number and number over 10 minutes, and vulva temperature of the sow in estrus period were increased (p < 0.05) compared with those of sow in non-estrus period, respectively. Detection of estrus using standing time and vulva temperature tended (p = 0.06) to increase the success rate when artificial insemination (AI) was performed. In conclusion, standing time and vulva temperature increased when estrus happened. Success rate of AI of sow using these methods showed an increasing trend. Therefore, existing method using the naked eye can be replaced to new method such as vulvar temperature and standing time when detecting the estrus.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 50 条
  • [21] Assessment of pregnancy in the mare using digital infrared thermography
    Bowers, S.
    Gandy, S.
    Anderson, B.
    Ryan, P.
    Willard, S.
    JOURNAL OF DAIRY SCIENCE, 2004, 87 : 371 - 371
  • [22] Assessment of pregnancy in the mare using digital infrared thermography
    Bowers, S.
    Gandy, S.
    Anderson, B.
    Ryan, P.
    Willard, S.
    JOURNAL OF ANIMAL SCIENCE, 2004, 82 : 371 - 371
  • [23] Wearable System for Obstacle Detection and Human Assistance Using Ultrasonic Sensor Array
    Patankar, Ashish
    Nikoubin, Tooraj
    7TH INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION AND NETWORKING TECHNOLOGIES (ICCCNT 2016), 2016,
  • [24] Uncooled infrared sensor with digital focal plane array
    Marshall, C
    Butler, N
    Blackwell, R
    Murphy, R
    Breen, T
    INFRARED DETECTORS AND FOCAL PLANE ARRAYS IV, 1996, 2746 : 23 - 31
  • [25] Evaluation of infrared thermography combined with behavioral biometrics for estrus detection in naturally cycling dairy cows
    Marquez, H. J. Perez
    Ambrose, D. J.
    Schaefer, A. L.
    Cook, N. J.
    Bench, C. J.
    ANIMAL, 2021, 15 (07)
  • [26] Detection and Tracking of a Human Using the Infrared Thermopile Array Sensor -"Grid -EYE"
    Shetty, Akshaya D.
    Disha
    Shubha, B.
    Suryanarayana, K.
    2017 INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING, INSTRUMENTATION AND CONTROL TECHNOLOGIES (ICICICT), 2017, : 1490 - 1495
  • [27] Fall detection on embedded platform using infrared array sensor for healthcare applications
    Jiang, Yan
    Gong, Tianyi
    He, Lingfeng
    Yan, Shicheng
    Wu, Xiaoping
    Liu, Jianyang
    NEURAL COMPUTING & APPLICATIONS, 2023, 36 (09): : 5093 - 5108
  • [28] Fall detection on embedded platform using infrared array sensor for healthcare applications
    Yan Jiang
    Tianyi Gong
    Lingfeng He
    Shicheng Yan
    Xiaoping Wu
    Jianyang Liu
    Neural Computing and Applications, 2024, 36 : 5093 - 5108
  • [29] Reception tests of the WEST PFUs using ultrasonic testing and infrared thermography
    Ramaniraka, M.
    Richou, M.
    Vignal, N.
    Addab, Y.
    Missirlian, M.
    NUCLEAR MATERIALS AND ENERGY, 2022, 32
  • [30] Infrared Thermography Sensor for Disease Activity Detection in Rheumatoid Arthritis Patients
    Pauk, Jolanta
    Wasilewska, Agnieszka
    Ihnatouski, Mikhail
    SENSORS, 2019, 19 (16)