Frictional resistance of removable partial dentures with retrofitted resin composite guide planes

被引:0
|
作者
NaBadalung, DP
Nicholls, JI
Brudvik, JS
机构
[1] UNIV WASHINGTON,SCH DENT,DEPT RESTORAT DENT,SEATTLE,WA 98195
[2] UNIV WASHINGTON,SCH DENT,DEPT PROSTHODONT,SEATTLE,WA 98195
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Frictional resistance to the dislodging forces of a removable partial denture with and without resin composite retrofitted guide planes was compared in vitro. Six master models of four natural teeth, each simulating a Kennedy Class III modification 1 arch, were used. Guide planes were prepared, and 18 cobalt-chromium removable partial denture frameworks without clasps were fabricated. Three resin composite materials were applied to the guide planes as retrofitting materials. Following this, the resistance to dislodgment of the removable partial denture framework was evaluated under cyclic dislodgment, and the resistance to dislodgment before and after resin composite retrofitted guide planes was compared. The dislodgment force was recorded every 500 cycles. Testing was concluded when the dislodging force value reached 50% of the initial value. There was a significant difference between the dislodging forces with and without retrofitted guide planes. Higher dislodging forces were recorded when resin composite retrofitted guide planes were used. Z100 was the most effective retrofitting material under cyclic dislodgment, and Heliomolar and Herculite XR performed similarly.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 50 条
  • [21] COMBINING RESIN-BONDED PROSTHESES AND REMOVABLE PARTIAL DENTURES - REPORT OF CASE
    CAUGHMAN, WF
    COMER, RW
    DUNCAN, JD
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1987, 114 (02): : 187 - 189
  • [22] In vitro comparison of guide planes for removable partial dentures prepared with CAD-CAM-assisted templates, guiding rod templates, and freehand
    Cheng, Ni
    Yu, Hai
    Shan, Wenxi
    Wu, Jiang
    JOURNAL OF DENTISTRY, 2024, 149
  • [23] Comparison of four CAD-CAM guides for preparing guiding planes of removable partial dentures
    Bai, Hefei
    Ye, Hongqiang
    Chen, Hu
    Wang, Yong
    Zhou, Yongsheng
    Sun, Yuchun
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 146
  • [24] Comparison of four CAD-CAM guides for preparing guiding planes of removable partial dentures
    Bai, Hefei
    Ye, Hongqiang
    Chen, Hu
    Wang, Yong
    Zhou, Yongsheng
    Sun, Yuchun
    Computers in Biology and Medicine, 2022, 146
  • [25] Cost-effectiveness analysis of prosthetic treatment with thermoplastic resin removable partial dentures
    Fueki, Kenji
    Inamochi, Yuka
    Yoshida-Kohno, Eiko
    Wakabayashi, Noriyuki
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (01) : 52 - 55
  • [26] A Technique to Facilitate Tooth Modification for Removable Partial Denture Prosthesis Guide Planes
    Haeberle, C. Brent
    Abreu, Amara
    Metzler, Kurt
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (05): : 414 - 417
  • [27] ABRASION OF ENAMEL AND COMPOSITE RESIN BY REMOVABLE PARTIAL DENTURE CLASPS
    HEBEL, KS
    GRASER, GN
    FEATHERSTONE, JDB
    JOURNAL OF PROSTHETIC DENTISTRY, 1984, 52 (03): : 389 - 397
  • [28] Fabricating abutment crowns for existing removable partial dentures using custom resin clasp analogs
    Livaditis, GJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (05): : 619 - 629
  • [29] Clinical performance of resin-bonded fixed partial dentures and extracoronal attachments for removable prostheses
    Besimo, C
    Gachter, M
    Jahn, M
    Hassell, T
    JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (05): : 465 - 471
  • [30] STABILIZING PERIODONTALLY WEAKENED TEETH BY USING GUIDE PLANE REMOVABLE PARTIAL DENTURES - A PRELIMINARY REPORT
    RUDD, KD
    OLEARY, TJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1966, 16 (04): : 721 - +