Using Genetic Algorithm for Electrode Movement Problem in Electrical Impedance Tomography

被引:0
|
作者
Li, Xuefei [2 ]
Luo, Ciyong [1 ]
Wang, Ping [1 ]
Chen, Minyou [1 ]
He, Wei [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] CISDI Engn CO LTD, Chongqing 400013, Peoples R China
关键词
Electrode Movement Problem; Electrical Impedance Tomography; Genetic Algorithm;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Electrical Impedance Tomography (EIT) attempts to reconstruct the internal impedance distribution in a medium according to electrical measurements with electrodes on the medium surface. Main problem of EIT is the drift of electrodes during the medical applications, in which the body surface moves during breathing and posture change. In this paper, a new approach which can distinguish electrode movements from measurement data of EIT for eliminating such effects in static reconstructed image is presented. To achieve these objectives, this paper proposed a linear model to describe affection of boundary voltages caused by electrode movements. A genetic algorithm for the problems is introduced, which attempted to rind the optimization of electrode movements to match the measurement voltages. To get least number of iterations possible, we introduce cultivation process in mutation operator. Simulation experiments show that the genetic algorithm is efficient and effective for electrode movement problem.
引用
收藏
页码:1804 / +
页数:2
相关论文
共 50 条
  • [41] JUSTIFICATION OF POINT ELECTRODE MODELS IN ELECTRICAL IMPEDANCE TOMOGRAPHY
    Hanke, Martin
    Harrach, Bastian
    Hyvonen, Nuutti
    MATHEMATICAL MODELS & METHODS IN APPLIED SCIENCES, 2011, 21 (06): : 1395 - 1413
  • [42] A direct reconstruction algorithm for electrical impedance tomography
    Mueller, JL
    Siltanen, S
    Isaacson, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (06) : 555 - 559
  • [43] Comparison study of line electrode and compound electrode in electrical impedance tomography
    Wang, Yan
    Sha, Hong
    Ren, Chaoshi
    DYNAMICS OF CONTINUOUS DISCRETE AND IMPULSIVE SYSTEMS-SERIES B-APPLICATIONS & ALGORITHMS, 2006, 13E : 1565 - 1568
  • [44] An Algorithm for Cavity Reconstruction in Electrical Impedance Tomography
    FENG TIAN-HONG AND MA FU-MING (School of Mathematics
    CommunicationsinMathematicalResearch, 2011, 27 (03) : 278 - 287
  • [45] A regularised electrical impedance tomography reconstruction algorithm
    Hua, P.
    Webster, J.G.
    Tompkins, W.J.
    Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 137 - 141
  • [46] A hybrid reconstruction algorithm for electrical impedance tomography
    Hu, Li
    Wang, Huaxiang
    Zhao, Bo
    Yang, Wuqiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (03) : 813 - 818
  • [47] Estimation of electrode contact impedance and conductivity of single-layer graphene using electrical impedance tomography
    Khambampati, Anil Kumar
    Sharma, Sunam Kumar
    Kim, Kyung Youn
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (08)
  • [48] Application of a hybrid genetic/powell algorithm and a boundary element method to electrical impedance tomography
    Hsiao, CT
    Chahine, G
    Gumerov, N
    JOURNAL OF COMPUTATIONAL PHYSICS, 2001, 173 (02) : 433 - 454
  • [49] Image Reconstruction Using a Genetic Algorithm for Electrical Capacitance Tomography
    牟昌华
    彭黎辉
    姚丹亚
    萧德云
    Tsinghua Science and Technology, 2005, (05) : 587 - 592
  • [50] TRANSTHORACIC ELECTRICAL-IMPEDANCE - ARTIFACTS ASSOCIATED WITH ELECTRODE MOVEMENT
    HULL, ET
    IRIE, T
    HEEMSTRA, H
    WILDEVUUR, CRH
    EUROPEAN SURGICAL RESEARCH, 1976, 8 : 184 - 185