Calibration of NIR 2 of Spectral Profiler Onboard Kaguya/SELENE

被引:12
|
作者
Yamamoto, Satoru [1 ]
Matsunaga, Tsuneo [1 ]
Ogawa, Yoshiko [2 ]
Nakamura, Ryosuke [3 ]
Yokota, Yasuhiro [1 ]
Ohtake, Makiko [4 ]
Haruyama, Junichi [4 ]
Morota, Tomokatsu [5 ]
Honda, Chikatoshi [2 ]
Hiroi, Takahiro [6 ]
Kodama, Shinsuke [3 ]
机构
[1] Natl Inst Environm Studies, Ctr Environm Measurement & Anal, Tsukuba, Ibaraki 3058506, Japan
[2] Univ Aizu, ARC Space CAIST, Aizu Wakamatsu, Fukushima 9658560, Japan
[3] Natl Inst Adv Ind Sci & Technol, Informat Technol Res Inst, Tsukuba, Ibaraki 3058568, Japan
[4] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Sagamihara, Kanagawa 2525210, Japan
[5] Nagoya Univ, Grad Sch Environm Studies, Nagoya, Aichi 4648601, Japan
[6] Brown Univ, Dept Geol Sci, Providence, RI 02912 USA
来源
关键词
Infrared spectroscopy; Moon; remote sensing; spectral analysis; spectroscopy; ONE MOON; SPECTROSCOPY; REFLECTANCE; PYROXENE; OLIVINE; ORIGIN; FLIGHT;
D O I
10.1109/TGRS.2014.2304581
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The Spectral Profiler (SP) is a visible-near infrared spectrometer onboard the Japanese Selenological and Engineering Explorer (SELENE), which was launched in 2007 and observed the Moon until June 2009. The SP consists of two gratings and three linear-array detectors: VIS (0.5-1.0 mu m), NIR 1 (0.9-1.7 mu m), and NIR 2 (1.7-2.6 mu m). In this paper, we propose a new method for radiometric calibration of NIR 2, specifically for the dark output (background) estimate, which is different from the previous method used for VIS and NIR 1. We show that the reflectance spectra of NIR 2 derived from the new radiometric calibration show less noise than those of the previous method. Based on an analysis of the reflectance spectra at exposure sites of the end-member minerals on the lunar surface, we demonstrated that the spectral features of the 2-mu m band in the NIR 2 spectra are consistent with those expected from the minerals inferred from the features of the 1-mu m band in the VIS and NIR 1 spectra. Finally, we examined the repeatability of the radiometric calibration of NIR 2 using the SP data near the Apollo 16 landing site observed at four different times. The typical difference in the reflectance at wavelengths <similar to 2.1 mu m was a few percent, which is within the uncertainty due to the error in the background estimate, suggesting that there was no significant change in the sensitivity of NIR 2 over the mission period.
引用
收藏
页码:6882 / 6898
页数:17
相关论文
共 50 条
  • [31] Calibration for the Solar Reflective Bands of Medium Resolution Spectral Imager Onboard FY-3A
    Hu, Xiuqing
    Sun, Ling
    Liu, Jingjng
    Ding, Lei
    Wang, Xianghua
    Li, Yuan
    Zhang, Yong
    Xu, Na
    Chen, Lin
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2012, 50 (12): : 4915 - 4928
  • [32] Retrieval of spectral response functions for the hyper-spectral sensor of HISUI (Hyper-spectral Imager SUIte) by means of onboard calibration sources
    Tatsumi, Kenji
    Ohgi, Nagamitsu
    Harada, Hisashi
    Kawanishi, Toneo
    Sakuma, Fumihiro
    Inada, Hitomi
    Kawashima, Takahiro
    Iwasaki, Akira
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XV, 2011, 8176
  • [33] Quality characterisation of crude oils by partial least square calibration of NIR spectral profiles
    Hidajat, K
    Chong, SM
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2000, 8 (01) : 53 - 59
  • [34] A novel NIR spectral calibration method: Sparse coefficients wavelength selection and regression (SCWR)
    Lei, Tong
    Sun, Da-Wen
    [J]. ANALYTICA CHIMICA ACTA, 2020, 1110 (1110) : 169 - 180
  • [35] SPATIAL AND SPECTRAL CALIBRATION METHODS FOR MONOLITHIC VIS/NIR AND VIS/SWIR HYPERSPECTRAL SENSORS
    Stark, M.
    Goldstein, N.
    St Peter, B.
    Tannian, B.
    [J]. 2019 10TH WORKSHOP ON HYPERSPECTRAL IMAGING AND SIGNAL PROCESSING - EVOLUTION IN REMOTE SENSING (WHISPERS), 2019,
  • [36] Designing a calibration set in spectral space for efficient development of an NIR method for tablet analysis
    Alam, Md Anik
    Drennen, James, III
    Anderson, Carl
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 : 230 - 239
  • [37] Characterization of Terra and Aqua MODIS VIS, NIR, and SWIR Spectral Bands' Calibration Stability
    Wu, Aisheng
    Xiong, Xiaoxiong
    Doelling, David R.
    Morstad, Daniel
    Angal, Amit
    Bhatt, Rajendra
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (07): : 4330 - 4338
  • [38] Retrieval of spectral response functions for the hyper-spectral sensor of HISUI (Hyper-spectral Imager SUIte) by means of onboard calibration sources
    Tatsumi, Kenji
    Ohgi, Nagamitsu
    Harada, Hisashi
    Kawanishi, Toneo
    Sakuma, Fumihiro
    Inada, Hitomi
    Kawashima, Takahiro
    Iwasaki, Akira
    [J]. Proceedings of SPIE - The International Society for Optical Engineering, 2011, 8176
  • [39] Calibration Method of High Spectral Infrared Atmospheric Sounder Onboard FY-3D Satellite
    Qi, Chengli
    Gu, Mingjian
    Wu, Chunqiang
    Hu, Xiuqing
    [J]. 3RD INTERNATIONAL SYMPOSIUM OF SPACE OPTICAL INSTRUMENTS AND APPLICATIONS, 2017, 192 : 211 - 219
  • [40] Calibration transfer based on the weight matrix (CTWM) of PLS for near infrared (NIR) spectral analysis
    Zhang, Feiyu
    Zhang, Ruoqiu
    Ge, Jiong
    Chen, Wanchao
    Yang, Wuye
    Du, Yiping
    [J]. ANALYTICAL METHODS, 2018, 10 (18) : 2169 - 2179