Instrumented Ergonomic Risk Assessment Using Wearable Inertial Measurement Units: Impact of Joint Angle Convention

被引:26
|
作者
Humadi, Ahmed [1 ]
Nazarahari, Milad [1 ]
Ahmad, Rafiq [1 ]
Rouhani, Hossein [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Edmonton, AB T6G 1H9, Canada
关键词
Task analysis; Three-dimensional displays; Two dimensional displays; Biomedical monitoring; Kinematics; Cameras; Risk management; Ergonomic risk assessment; inertial measurement unit; material handling tasks; RULA; work-related musculoskeletal disorders; ISB RECOMMENDATION; COORDINATE SYSTEM; SENSORS; MOTION; EXPOSURE; KINECT; DEFINITIONS; CALIBRATION; VALIDATION; SHOULDER;
D O I
10.1109/ACCESS.2020.3048645
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The Rapid Upper Limb Assessment (RULA) is frequently used to monitor body posture for early risk prevention of work-related musculoskeletal disorders. However, RULA measurements that are based on workers' self-report or external rater observation suffer from low repeatability. Thus, the objective of this study was to investigate the accuracy and repeatability of an inertial measurement unit (IMU) system for in-field RULA score assessment during manual material handling tasks using 3D Cardan angles and 2D projection angles against reference values obtained by a motion-capture camera system. The experimental results showed that for trunk and neck joint angles, the 2D convention had significantly (p < 0.05) smaller root-mean-square error (RMSE), while for other upper-body angles, the convention with significantly smaller RMSE depended on the angle under analysis. Also, the 3D convention showed a "moderate" agreement with the reference system, while the 2D convention showed a "substantial" agreement for two tasks and a "moderate" agreement for one task. Moreover, the intraclass correlation coefficients ranged from 0.82 to 0.94 for the 3D convention and 0.87 to 0.95 for the 2D convention for repeated trials performed by each participant. Therefore, the wearable IMU system, along with the 2D convention, could be considered as an accurate and repeatable ergonomic risk assessment tool.
引用
收藏
页码:7293 / 7305
页数:13
相关论文
共 50 条
  • [21] Upper limb joint kinematics using wearable magnetic and inertial measurement units: an anatomical calibration procedure based on bony landmark identification
    Picerno, Pietro
    Caliandro, Pietro
    Iacovelli, Chiara
    Simbolotti, Chiara
    Crabolu, Michele
    Pani, Danilo
    Vannozzi, Giuseppe
    Reale, Giuseppe
    Rossini, Paolo Maria
    Padua, Luca
    Cereatti, Andrea
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [22] A Hidden Markov Model of the Breaststroke Swimming Temporal Phases Using Wearable Inertial Measurement Units
    Dadashi, Farzin
    Arami, Arash
    Crettenand, Florent
    Millet, Gregoire P.
    Komar, John
    Seifert, Ludovic
    Aminian, Kamiar
    2013 IEEE INTERNATIONAL CONFERENCE ON BODY SENSOR NETWORKS (BSN), 2013,
  • [23] Slip Detection and Prediction in Human Walking Using Only Wearable Inertial Measurement Units (IMUs)
    Trkov, Mitja
    Chen, Kuo
    Yi, Jingang
    Liu, Tao
    2015 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2015, : 854 - 859
  • [24] Toward Real-Time Detection of Object Lifting Using Wearable Inertial Measurement Units
    Miller, Benjamin A.
    Novak, Domen
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6831 - 6834
  • [25] Kalman Filter for Angle Estimation using Dual Inertial Measurement Units on Unicycle Robot
    Charel, Ekti Radin S.
    Binugroho, Eko Henfri
    Rosyidi, M. Anfa'ur
    Dewanto, R. Sanggar
    Pramadihanto, Dadet
    2016 INTERNATIONAL ELECTRONICS SYMPOSIUM (IES), 2016, : 256 - 261
  • [26] Construction Activity Recognition and Ergonomic Risk Assessment Using a Wearable Insole Pressure System
    Antwi-Afari, Maxwell Fordjour
    Li, Heng
    Umer, Waleed
    Yu, Yantao
    Xing, Xuejiao
    JOURNAL OF CONSTRUCTION ENGINEERING AND MANAGEMENT, 2020, 146 (07)
  • [27] Ergonomic assessment of office worker postures using 3D automated joint angle assessment
    Rodrigues, Patrick B.
    Xiao, Yijing
    Fukumura, Yoko E.
    Awada, Mohamad
    Aryal, Ashrant
    Becerik-Gerber, Burcin
    Lucas, Gale
    Roll, Shawn C.
    ADVANCED ENGINEERING INFORMATICS, 2022, 52
  • [28] Automatic Functional Shoulder Task Identification and Sub-Task Segmentation Using Wearable Inertial Measurement Units for Frozen Shoulder Assessment
    Chang, Chih-Ya
    Hsieh, Chia-Yeh
    Huang, Hsiang-Yun
    Wu, Yung-Tsan
    Chen, Liang-Cheng
    Chan, Chia-Tai
    Liu, Kai-Chun
    SENSORS, 2021, 21 (01) : 1 - 24
  • [29] Center of Mass Estimation for Impaired Gait Assessment Using Inertial Measurement Units
    Labrozzi, Gabrielle C.
    Warner, Holly
    Makowski, Nathaniel S.
    Audu, Musa L.
    Triolo, Ronald J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 12 - 22
  • [30] ASSESSMENT OF LUMBAR SPINAL MOBILITY USING INERTIAL MEASUREMENT UNITS IN AXIAL SPONDYLOARTHRITIS
    Franco, L.
    Ward, W.
    Sengupta, R.
    Cazzola, D.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2018, 36 (04) : 756 - 756