An evaluation of the validity and potential utility of facial electromyelogram Responsiveness Index for sedation monitoring in critically ill patients

被引:9
|
作者
Walsh, Timothy S. [1 ]
Everingham, Kirsty
Frame, Fiona [1 ]
Lapinlampi, T. Petteri [2 ]
Sarkela, Mika O. K. [2 ]
Uutela, Kimmo [2 ]
Viertio-Oja, Hanna E. [2 ]
机构
[1] Queens Med Res Inst, Ctr Inflammat Res, Edinburgh EH16 4TJ, Midlothian, Scotland
[2] GE Healthcare Finland Oy, FI-00510 Helsinki, Finland
关键词
Sedation; Monitoring; Critical care; INTENSIVE-CARE-UNIT; BISPECTRAL INDEX; ICU PATIENTS; AGITATION; ENTROPY; RELIABILITY; RAMSAY; SAFETY; SCALE;
D O I
10.1016/j.jcrc.2014.05.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The purpose of this study is to explore the validity of a novel sedation monitoring technology based on facial electromyelography (EMG) in sedated critically ill patients. Materials and methods: The Responsiveness Index (RI) integrates the preceding 60 minutes of facial EMG data. An existing data set was used to derive traffic light cut-offs for low (red), intermediate (amber), and higher (green) states of patient arousal. The validity of these was prospectively evaluated in 30 sedated critically ill patients against hourly Richmond Agitation Sedation Scale (RASS) assessments with concealment of RI data from clinical staff. Results: With derivation data, an RI less than or equal to 35 had best discrimination for a Ramsay score of 5/6 (sensitivity, 90%; specificity, 79%). For traffic lights, we chose RI less than or equal to 20 as red, 20 to 40 as amber, and more than 40 as green. In the prospective study, RI values were red/amber for 76% of RASS -5/-4 assessments, but RI varied dynamically over time in many patients, and discordance with RASS may have resulted from the use of 1 hour of data for RI calculations. We also noted that red/amber values resulted from sleep, encephalopathy, and low levels of stimulation. Conclusions: Responsiveness Index is not directly comparable with clinical sedation scores but is a potential continuous alert to possible deep sedation in critically ill patients. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:886.e1 / 886.e7
页数:7
相关论文
共 50 条
  • [41] Evaluation of perfusion index as a tool for pain assessment in critically ill patients
    Hasanin, Ahmed
    Mohamed, Sabah Abdel Raouf
    El-adawy, Akram
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) : 961 - 965
  • [42] Actigraphic monitoring in critically ill patients: Preliminary results toward an "observation-guided sedation"
    Mistraletti, Giovanni
    Taverna, Martina
    Sabbatini, Giovanni
    Carloni, Elisabetta
    Bolgiaghi, Luca
    Pirrone, Massimitiano
    Cigada, Marco
    Destrebecq, Anne Lucia Leona
    Carli, Franco
    Iapichino, Gaetano
    JOURNAL OF CRITICAL CARE, 2009, 24 (04) : 563 - 567
  • [43] Assessment of the plethysmographic variability index as a predictor of fluid responsiveness in critically ill patients: a pilot study
    Baker, A. K.
    Partridge, R. J. O.
    Litton, E.
    Ho, K. M.
    ANAESTHESIA AND INTENSIVE CARE, 2013, 41 (06) : 736 - 741
  • [44] UTILITY OF MONITORING CONTINUOUS MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    CHELLURI, L
    JASTREMSKI, MS
    BAILLY, RT
    BENEY, KM
    CHEST, 1986, 89 (06) : S479 - S479
  • [45] Evaluation of a noninvasive blood glucose monitoring device for critically ill patients
    A Kononenko
    D Dvir
    B Grunberg
    J Cohen
    E Gabis
    P Singer
    Critical Care, 10 (Suppl 1):
  • [46] Utility of transthoracic echocardiography (TTE) in assessing fluid responsiveness in critically ill patients - a challenge for the bedside sonographer
    Mielnicki, Wojciech
    Dyla, Agnieszka
    Zawada, Tomasz
    MEDICAL ULTRASONOGRAPHY, 2016, 18 (04) : 508 - 514
  • [47] Evaluation of lacrimal fluid as an alternative for monitoring glucose in critically ill patients
    LeBlanc, JM
    Haas, CE
    Vicente, G
    Colon, LA
    INTENSIVE CARE MEDICINE, 2005, 31 (10) : 1442 - 1445
  • [48] Evaluation of lacrimal fluid as an alternative for monitoring glucose in critically ill patients
    Jaclyn M. LeBlanc
    Curtis E. Haas
    Glorimar Vicente
    Luis A. Colon
    Intensive Care Medicine, 2005, 31 : 1442 - 1445
  • [49] Evaluation of a noninvasive blood glucose monitoring device for critically ill patients
    O Amir
    D Dvir
    B Grunberg
    J Cohen
    E Gabis
    P Singer
    Critical Care, 12 (Suppl 2):
  • [50] Assessment of sedation level in critically ill mechanically ventilated patients: Is bispectral index correlated with Richmond agitation-sedation scale?
    Hashemi, Seyed Jalal
    Soltani, Hassanali
    Taakoob, Reyhanak
    Soleymani, Bahram
    Zeraatkari, Khadije
    Shahin, Samireh
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2008, 13 (04): : 181 - 185