Characterization of noise sources in a microfabricated single-beam zero-field optically-pumped magnetometer

被引:57
|
作者
Krzyzewski, S. P. [1 ]
Perry, A. R. [1 ]
Gerginov, V. [1 ]
Knappe, S. [1 ]
机构
[1] Univ Colorado, Boulder, CO 80309 USA
基金
美国国家卫生研究院;
关键词
ATOMIC MAGNETOMETRY; LIGHT SHIFTS; MAGNETOENCEPHALOGRAPHY; RESONANCE; LINES; ARRAY;
D O I
10.1063/1.5098088
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present an experimental noise characterization of a miniature single-beam absorption-based optically-pumped magnetometer with a noise floor of 7fT/Hz(1/2) operating in the spin-exchange relaxation-free regime. We experimentally evaluate noise arising from the laser intensity, laser frequency, laser polarization, cell temperature, and magnetic field coils used for the phase-sensitive detection of the magnetometer signal. We find that noise in the range between DC and 30Hz is a result of noise sources coupling to the atoms in a manner similar to a magnetic field, while the noise at frequencies above 30Hz is mainly due to laser intensity noise. Our results place an upper limit on the noise sources for our system that matches well with the noise spectrum of the magnetometer at frequencies above 5Hz.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Magnetic field search and locking scheme for all-optical single-beam atomic magnetometer
    Zhang, Weidong
    Xu, Xiaotian
    Liao, Tianxiang
    Fan, Jingyun
    Yang, Sheng-Jun
    CHINESE OPTICS LETTERS, 2025, 23 (02)
  • [32] Characterizing current noise of commercial constant-current sources by using an optically pumped rubidium atomic magnetometer
    Zhao, Ni
    Zhang, Lulu
    Yang, Yongbiao
    He, Jun
    Wang, Yanhua
    Li, Tingyu
    Wang, Junmin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (09):
  • [33] ZERO-FIELD LEVEL-CROSSING RESONANCES IN OPTICALLY PUMPED 23SL HE-4
    SLOCUM, RE
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (11): : 1127 - 1127
  • [34] Detection of ultra-low field NMR signal with a commercial QuSpin single-beam atomic magnetometer
    Savukov, Igor
    Kim, Young Jin
    Schultz, Gregory
    JOURNAL OF MAGNETIC RESONANCE, 2020, 317
  • [35] Zero Magnetic Field Calibration for Single-Beam Atomic Magnetometers Using Second Harmonics
    Saenyot, Khanuengchat
    Shoji, Yuya
    Takahashi, Shunya
    Daibo, Masahiro
    IEEE MAGNETICS LETTERS, 2019, 10
  • [36] ZERO-FIELD LEVEL-CROSSING RESONANCES IN OPTICALLY PUMPED 2S-31 HE-4
    SLOCUM, RE
    PHYSICAL REVIEW LETTERS, 1972, 29 (25) : 1642 - &
  • [37] MEASUREMENT OF WEAK MAGNETIC-FIELDS USING ZERO-FIELD PARAMETRIC RESONANCE IN OPTICALLY PUMPED HE-4
    SLOCUM, RE
    MARTON, BI
    IEEE TRANSACTIONS ON MAGNETICS, 1973, MAG9 (03) : 221 - 226
  • [38] Combined effect of pump-light intensity and modulation field on the performance of optically pumped magnetometers under zero-field parametric modulation
    Wang, Jing
    Fan, Wenfeng
    Yin, Kaifeng
    Yan, Yeguang
    Zhou, Binquan
    Song, Xinda
    PHYSICAL REVIEW A, 2020, 101 (05)
  • [39] High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement
    Tang, Junjian
    Zhai, Yueyang
    Cao, Li
    Zhang, Yaohua
    Li, Lin
    Zhao, Binbin
    Zhou, Binquan
    Han, Bangcheng
    Liu, Gang
    OPTICS EXPRESS, 2021, 29 (10) : 15641 - 15652
  • [40] DC-Bias-Magnetic-Field Dependence of Step Response in an Elliptically Polarized Single-Beam Atomic Magnetometer
    Shoji, Yuya
    Khanuengchat, Saenyot
    Takahashi, Shunya
    Daibo, Masahiro
    2020 8TH INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2020,