A new development in ultrasound-compatible gynecologic brachytherapy simulators

被引:9
|
作者
Fields, Emma C. [1 ]
Joyner, Melissa M. [2 ]
Singer, Lisa [3 ]
Todor, Dorin [1 ]
机构
[1] Virginia Commonwealth Univ, Massey Canc Ctr, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Univ Texas MD Anderson Canc Ctr, Radiat Oncol Div, Houston, TX 77030 USA
[3] Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
关键词
Brachytherapy; Pelvic model; Pelvic simulator; Pelvic phantom; Resident education; Cervical cancer; CERVICAL-CANCER; RESIDENTS;
D O I
10.1016/j.brachy.2020.09.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Gynecologic brachytherapy is an essential component in the curative treatment of cervical cancer. With the decline in brachytherapy utilization, gynecologic brachytherapy simulators are being used to provide a mechanism to enhance proficiency-based resident training. However, most models that have been used lack procedural fidelity as they are either repurposed from OB/GYN basic models or from physics phantoms. Therefore, we set out to develop a high-fidelity, ultrasound- and CT-compatible gynecologic brachytherapy training simulator. METHODS AND MATERIALS: Based on prior experience with gynecologic training simulators on the market, we developed a wish list for an ultrasound-compatible brachytherapy training model. A custom simulator was developed based on an existing pelvic ultrasound trainer. Features included a cervical os and endometrial canal as well as a palpable and hypoechoic cervical tumor. RESULTS: The model took about 3 months from the initial meeting with the developer to completion. The properties of the material were equivalent to water for ultrasound, CT, and also MRI and the model did not show signs of degradation after multiple tandem insertions. CONCLUSIONS: A high-fidelity ultrasound-compatible simulator was effectively developed and utilized to improve resident training to perform brachytherapy implants with a derivative benefit in the long term of improving survival for women with advanced gynecologic malignancies through having access to more proficient brachytherapists. Future directions include enhancing the model to allow for repetitive needle insertion and suturing for interstitial training as well as creating variations in anatomy (e.g., retroverted uterus, bulky tumors, etc.) for more advanced technical training. (C) 2020 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:783 / 786
页数:4
相关论文
共 50 条
  • [1] Image Quality Through Ultrasound-Compatible Cylinders for Transvaginal Ultrasound-Guided Gynecologic High-Dose-Rate Brachytherapy
    Elburg, D. V.
    Roumeliotis, M.
    Fenster, A.
    Rodgers, J.
    Meyer, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E790 - E790
  • [2] Technical Note: Commissioning of an ultrasound-compatible surrogate vaginal cylinder for transvaginal ultrasound-based gynecologic high-dose-rate brachytherapy
    Van Elburg, Devin
    Roumeliotis, Michael
    Fenster, Aaron
    Phan, Tien
    Meyer, Tyler
    MEDICAL PHYSICS, 2022, 49 (04) : 2203 - 2211
  • [3] Ultrasound-Compatible Electrode for Functional Electrical Stimulation
    Moon, Sunho
    Xue, Xiangming
    Ganesh, Vidisha
    Shukla, Darpan
    Kreager, Benjamin C.
    Cai, Qianqian
    Wu, Huaiyu
    Zhu, Yong
    Sharma, Nitin
    Jiang, Xiaoning
    BIOMEDICINES, 2024, 12 (08)
  • [4] The Assessment of a Novel Endoscopic Ultrasound-Compatible Cryocatheter to Ablate Pancreatic Cancer
    Baust, John M.
    Robilotto, Anthony
    Raijman, Isaac
    Santucci, Kimberly L.
    Van Buskirk, Robert G.
    Baust, John G.
    Snyder, Kristi K.
    BIOMEDICINES, 2024, 12 (03)
  • [5] DEVELOPMENT AND INITIAL VALIDATION OF A LOW-COST ULTRASOUND-COMPATIBLE SUPRAPUBIC CATHETER INSERTION TRAINING SIMULATOR
    Wang, Yuding
    Hoogenes, Jen
    Blankstein, Udi
    Al-Hashimi, Ali
    Shayegan, Bobby
    Matsumoto, Edward
    JOURNAL OF UROLOGY, 2019, 201 (04): : E150 - E151
  • [6] Use of Ultrasound-Compatible Models for Simulation-Based Gynecological Education
    Singer, L.
    Damast, S.
    Chino, J.
    Taunk, N.
    Lin, L.
    Lee, L.
    Mohindra, P.
    Bradley, K.
    Fisher, C.
    Fields, E.
    Joyner, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S1098 - S1099
  • [7] Development of a 360° transvaginal ultrasound needle guidance system for interstitial gynecologic brachytherapy
    Rodgers, Jessica
    Bax, Jeffrey
    Surry, Kathleen
    D'Souza, David
    Leung, Eric
    Fenster, Aaron
    MEDICAL PHYSICS, 2017, 44 (08) : 4399 - 4399
  • [8] THE USE OF INTRAOPERATIVE TRANSABDOMINAL ULTRASOUND IN GYNECOLOGIC BRACHYTHERAPY
    RUSH, S
    GOTTESMAN, R
    LOVECCHIO, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (04): : 1107 - 1107
  • [9] Development and Testing of an Ultrasound-Compatible Cardiac Phantom for Interventional Procedure Simulation Using Direct Three-Dimensional Printing
    Wang, Shu
    Noh, Yohan
    Brown, Jemma
    Roujol, Sebastien
    Li, Ye
    Wang, Shuangyi
    Housden, Richard
    Ester, Mar Casajuana
    Al-Hamadani, Maleha
    Rajani, Ronak
    Rhode, Kawal
    3D PRINTING AND ADDITIVE MANUFACTURING, 2020, 7 (06) : 269 - 278
  • [10] Versatile Ultrasound-Compatible Microfluidic Platform for In Vitro Microvasculature Flow Research and Imaging Optimization
    Mano, Tamar
    Grutman, Tal
    Ilovitsh, Tali
    ACS OMEGA, 2023, 8 (50): : 47667 - 47677