The accuracy of diagnostic tests for adenoid hypertrophy A systematic review

被引:27
|
作者
Major, Michael P. [1 ]
Saltaji, Humam [2 ]
El-Hakim, Hamdy [3 ]
Witmans, Manisha [4 ]
Major, Paul [5 ,6 ]
Flores-Mir, Carlos [7 ]
机构
[1] Univ Alberta, Interdisciplinary Airway Res Clin, Edmonton Clin Hlth Acad 5 476, Div Orthodont,Sch Dent,Fac Med & Dent, Edmonton, AB T6G 1C9, Canada
[2] Univ Alberta, Div Orthodont, Sch Dent, Fac Med & Dent, Edmonton, AB T6G 1C9, Canada
[3] Univ Alberta, Fac Med & Dent, Edmonton, AB T6G 1C9, Canada
[4] Edmonton Clin Hlth Acad, Fac Med & Dent, Sch Dent, Div Pediat, Edmonton, AB, Canada
[5] Univ Alberta, Sch Dent, Edmonton, AB T6G 1C9, Canada
[6] Univ Alberta, Dept Dent, Fac Med & Dent, Edmonton, AB T6G 1C9, Canada
[7] Univ Alberta, Sch Dent, Fac Med & Dent, Edmonton, AB T6G 1C9, Canada
来源
关键词
Systematic review; diagnosis; screening; adenoid hypertrophy; nasal obstruction; OBSTRUCTIVE SLEEP-APNEA; UPPER AIRWAY; NASAL CAVITY; CHILDREN; NASOPHARYNX; MORPHOLOGY; ENDOSCOPY; SYMPTOMS; LEVEL; SIZE;
D O I
10.14219/jada.2013.31
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. Adenoid hypertrophy may cause sleep-disordered breathing and altered craniofacial growth. The authors conducted a study to gauge the accuracy of alternative tests compared with nasoendoscopy (reference standard) for screening adenoid hypertrophy. Methods. The authors conducted a systematic review that included searches of electronic databases, hand searches of bibliographies of relevant articles and gray literature searches. They included all articles in which an alternative test was compared with nasoendoscopy in children with suspected nasal or nasopharyngeal airway obstruction. Results. The authors identified seven articles that were of poor to good quality. They identified the following alternative tests: multirow detector computed tomography (sensitivity, 92 percent; specificity, 97 percent), videofluoroscopy (sensitivity, 100 percent; specificity, 90 percent), rhinomanometry with decongestant (sensitivity, 83 percent; specificity, 83 percent) and clinical examination (sensitivity, 22 percent; specificity, 88 percent). Lateral cephalograms tended to have good to fair sensitivity (typically 61-75 percent) and poor specificity (41-55 percent) when adenoid size was evaluated but excellent to good specificity when airway patency was evaluated (68-96 percent). Conclusions. No ideal tool exists for dentists to screen adenoid hypertrophy, owing to access constraints, radiation concerns and suboptimal diagnostic accuracy. Research is needed to identify a low-risk, easily acceptable, highly valid diagnostic screening tool. Practical Implications. Although lateral cephalograms (which have good to fair sensitivity) and a thorough medical history (which has good specificity) are imperfect individually, when they are used together, they can compensate for each other's weaknesses. This combined approach is the best tool available to dentists for screening adenoid hypertrophy.
引用
收藏
页码:247 / 254
页数:8
相关论文
共 50 条
  • [31] A systematic review of the diagnostic accuracy of provocative tests of the neck for diagnosing cervical radiculopathy
    Sidney M. Rubinstein
    Jan J. M. Pool
    Maurits W. van Tulder
    Ingrid I. Riphagen
    Henrica C. W. de Vet
    [J]. European Spine Journal, 2007, 16 : 307 - 319
  • [32] Diagnostic Accuracy of Clinical Tests for Shoulder Impingement Syndrome Systematic Literature Review
    Pfaffle, Uta
    [J]. MANUELLE THERAPIE, 2014, 18 (03) : 125 - 133
  • [33] Diagnostic accuracy of examination tests for lateral elbow tendinopathy (LET)-A systematic review
    Karanasios, Stefanos
    Korakakis, Vasileios
    Moutzouri, Maria
    Drakonaki, Eleni
    Koci, Klaudia
    Pantazopoulou, Vasiliki
    Tsepis, Elias
    Gioftsos, George
    [J]. JOURNAL OF HAND THERAPY, 2022, 35 (04) : 541 - 551
  • [34] An overview of systematic reviews of diagnostic tests accuracy
    Bae, Jong-Myon
    [J]. EPIDEMIOLOGY AND HEALTH, 2014, 36
  • [35] The accuracy of symptoms, signs and diagnostic tests in the diagnosis of left ventricular dysfunction in primary care: A diagnostic accuracy systematic review
    Madhok, V.
    Falk, G.
    Rogers, A.
    Struthers, A. D.
    Sullivan, F. M.
    Fahey, T.
    [J]. BMC FAMILY PRACTICE, 2008, 9 (1)
  • [36] The accuracy of symptoms, signs and diagnostic tests in the diagnosis of left ventricular dysfunction in primary care: A diagnostic accuracy systematic review
    V Madhok
    G Falk
    A Rogers
    AD Struthers
    FM Sullivan
    T Fahey
    [J]. BMC Family Practice, 9
  • [37] Diagnostic accuracy of the nasal obstruction index in detecting adenoid hypertrophy in children without allergy
    Torretta, S.
    Marchisio, P.
    Esposito, S.
    Cappadona, M.
    Fattizzo, M.
    Pignataro, L.
    [J]. INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2011, 75 (01) : 57 - 61
  • [38] A Systematic Review on Diagnostic Test Accuracy of Fecal Immunochemical Tests for Colorectal Cancer Screening
    van Roon, Aafke H.
    van Dam, Leonie
    Arends, Lidia R.
    Zauber, Ann G.
    Young, Graeme P.
    van Ballegooijen, Marjolein
    Habbema, Dik F.
    van Leerdam, Monique E.
    Steyerberg, Ewout W.
    Kuipers, Ernst J.
    [J]. GASTROENTEROLOGY, 2014, 146 (05) : S409 - S410
  • [39] Accuracy of tuberculosis diagnostic tests in small ruminants: A systematic review and meta-analysis
    Roy, A.
    Infantes-Lorenzo, J. A.
    de la Cruz, M. L.
    Dominguez, L.
    Alvarez, J.
    Bezos, J.
    [J]. PREVENTIVE VETERINARY MEDICINE, 2020, 182
  • [40] Diagnostic Accuracy of 5 Dental Pulp Tests: A Systematic Review and Meta-analysis
    Mainkar, Anshul
    Kim, Sahng G.
    [J]. JOURNAL OF ENDODONTICS, 2018, 44 (05) : 694 - 702