Crack detection by stimulated infrared thermography

被引:4
|
作者
Bodnar, Jean-Luc [1 ]
机构
[1] Univ Reims, GRESPI ECATHERM, F-51687 Reims, France
来源
关键词
RANDOM-EXCITATION;
D O I
10.1051/epjap/2014130332
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this paper, the potential of stimulated infrared thermography is studied for the detection of cracks located in metallic materials. To start with, the feasibility of the method is shown with the use of numerical simulations. Stimulated infrared thermography allows detecting emerging cracks in samples whether reflective or not as well as non-emerging cracks. In addition, crack detection is due to the radiative effects and/or the thermal effects induced by the defects. Then, the experimental device implemented for the study is detailed. Finally, experiments confirm that stimulated infrared thermography enables to detect microscopic cracks, whether emerging or non-emerging, in metal samples.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Railroads Surface Crack detection using Active Thermography
    Ramzan, Bilawal
    Malik, Sohail
    Ahmad, S. M.
    Martarelli, Milena
    [J]. PROCEEDINGS OF 2021 INTERNATIONAL BHURBAN CONFERENCE ON APPLIED SCIENCES AND TECHNOLOGIES (IBCAST), 2021, : 183 - 197
  • [42] Lock-in inductive thermography for surface crack detection
    Oswald-Tranta, Beata
    [J]. THERMOSENSE: THERMAL INFRARED APPLICATIONS XL, 2018, 10661
  • [43] Induction thermography for automatic crack detection in automotive components
    Franco, L.
    Rodriguez, F.
    Otero, J.
    [J]. 13TH QUANTITATIVE INFRARED THERMOGRAPHY CONFERENCE, 2016, : 996 - 1005
  • [44] EARLY DETECTION OF THERMAL CONTRAST IN PULSED STIMULATED THERMOGRAPHY
    KRAPEZ, JC
    LEPOUTRE, F
    BALAGEAS, D
    [J]. JOURNAL DE PHYSIQUE IV, 1994, 4 (C7): : 47 - 50
  • [45] Detection of moisture in porous materials by infrared thermography
    Moropoulou, A
    Avdelidis, NP
    Haralampopoulos, G
    Anagnostopoulou, S
    [J]. THERMOSENSE XXIV, 2002, 4710 : 324 - 332
  • [46] Detection of carpal tunnel syndrome by infrared thermography
    Maxel, X.
    Bodnar, J. L.
    Stubbe, L.
    [J]. MECHANICS & INDUSTRY, 2014, 15 (05) : 363 - 370
  • [47] Laser Lock-in Thermography for Fatigue Crack Detection
    An, Yun-Kyu
    Kim, Ji Min
    Sohn, Hoon
    [J]. STRUCTURAL HEALTH MONITORING: RESEARCH AND APPLICATIONS, 2013, 558 : 76 - 83
  • [48] Surface crack detection in different materials with inductive thermography
    Oswald-Tranta, Beata
    [J]. THERMOSENSE: THERMAL INFRARED APPLICATIONS XXXIX, 2017, 10214
  • [49] Modeling and optimization of open crack detection by active thermography
    Thiam, A.
    Kneip, J. C.
    Mattei, S.
    Cicala, E.
    [J]. 13TH QUANTITATIVE INFRARED THERMOGRAPHY CONFERENCE, 2016, : 842 - 847
  • [50] Detection of Dentinal Microcracks Using Infrared Thermography
    Matsushita-Tokugawa, Manami
    Miura, Jiro
    Iwami, Yukiteru
    Sakagami, Takahide
    Izumi, Yui
    Mori, Naoya
    Hayashi, Mikako
    Imazato, Satoshi
    Takeshige, Fumio
    Ebisu, Shigeyuki
    [J]. JOURNAL OF ENDODONTICS, 2013, 39 (01) : 88 - 91