Determination of nickel by anodic adsorptive stripping voltammetry with a cation exchanger-modified carbon paste electrode

被引:39
|
作者
González, P [1 ]
Cortínez, VA [1 ]
Fontán, CA [1 ]
机构
[1] Univ Nacl San Luis, Fac Quim Bioquim & Farm, Dept Quim Analit Dr Carlos B Marone, San Luis, Argentina
关键词
nickel; carbon paste electrode; anodic adsorptive stripping voltammetry;
D O I
10.1016/S0039-9140(02)00381-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The behavior of a modified carbon paste electrode (CPE) for nickel determination by anodic adsorptive stripping voltammetry (AAdsSV) was studied. The electrode was built incorporating the Dowex 50W x 12 (H+ form) ion exchanger to a Nujol-graphite base paste. Ni2+ was preconcentrated on the electrode surface in open circuit conditions, with the reduction (- 1300 mV)/reoxidation step carried out in HCl solution (pH 3). During deposition time (5 min), the hydrogen evolution did not present obstacle in the quantification of nickel. For 12 min of accumulation and 5 min of deposition, nickel can be quantified up to 600 mug l(-1). The detection limit was 0.005 mug I - 1 at a linear potential scan rate of 200 mV s(-1). Interferences from Hg2+ and Ag2+ up to a concentration of 1 and 0.6 mg l(-1), respectively, were eliminated with the aid of the anion exchanger Dowex-2 (mesh 200-400) which was added to the sample in the preconcentration step. The tolerance for some metal ions such as Cu2+, Cd2+, Fe3+, Zn2+, Co2+ and Ph2+ was improved in the same way. The method was applied for the determination of nickel in samples of tap and mineral water. At the concentration level of 50 mug l(-1) of Ni2+ , the results were in good agreement with those obtained using Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). For a Ni2+ concentration of 5 mug l(-1), the results obtained showed better accuracy than those obtained by ICP-AES. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:679 / 690
页数:12
相关论文
共 50 条
  • [21] Trace determination of vardenafil hydrochloride in commercial formulation and human serum by adsorptive anodic stripping voltammetry at a carbon paste electrode
    Mohamed M. Ghoneim
    Amera M. Hassanein
    Nehal A. Salahuddin
    Hanaa S. El-Desoky
    Mona N. Elfiky
    Journal of Solid State Electrochemistry, 2013, 17 : 1891 - 1902
  • [22] Determination of gold by stripping voltammetry using a modified carbon paste electrode
    Gevorgyan, A.M.
    Vanyukov, V.V.
    Vakhnenko, S.V.
    2002, Maik Nauka (57):
  • [23] Trace determination of vardenafil hydrochloride in commercial formulation and human serum by adsorptive anodic stripping voltammetry at a carbon paste electrode
    Ghoneim, Mohamed M.
    Hassanein, Amera M.
    Salahuddin, Nehal A.
    El-Desoky, Hanaa S.
    Elfiky, Mona N.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2013, 17 (07) : 1891 - 1902
  • [24] Adsorptive anodic stripping voltammetry of zirconium(IV)-alizarin red S complex at a carbon paste electrode
    Yi-Heng Li
    Qiao-Ling Zhao
    Mei-Hua Huang
    Microchimica Acta, 2007, 157 : 245 - 249
  • [25] Determination of cardiac troponin I by anodic stripping voltammetry over mesoporous materials modified carbon paste electrode
    He, NY
    Guo, HS
    Ge, SX
    Yang, D
    Zhang, JN
    MOLECULAR SIEVES: FROM BASIC RESEARCH TO INDUSTRIAL APPLICATIONS, PTS A AND B, 2005, 158 : 2041 - 2048
  • [26] Determination of cardiac troponin I by anodic stripping voltammetry at SBA-15 modified carbon paste electrode
    Guo, HS
    He, NY
    Ge, SX
    Yang, D
    Zhang, JN
    NANOPOROUS MATERIALS IV, 2005, 156 : 695 - 702
  • [27] Adsorptive anodic stripping voltammetry of zirconium(IV)-alizarin red S complex at a carbon paste electrode
    Li, Yi-Heng
    Zhao, Qiao-Ling
    Huang, Mei-Hua
    MICROCHIMICA ACTA, 2007, 157 (3-4) : 245 - 249
  • [28] Use of adsorptive square-wave anodic stripping voltammetry at carbon paste electrode for the determination of amlodipine besylate in pharmaceutical preparations
    M. Kazemipour
    M. Ansari
    A. Mohammadi
    H. Beitollahi
    R. Ahmadi
    Journal of Analytical Chemistry, 2009, 64 : 65 - 70
  • [29] Use of adsorptive square-wave anodic stripping voltammetry at carbon paste electrode for the determination of amlodipine besylate in pharmaceutical preparations
    Kazemipour, M.
    Ansari, M.
    Mohammadi, A.
    Beitollahi, H.
    Ahmadi, R.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 64 (01) : 65 - 70
  • [30] Adsorptive stripping voltammetry of nickel at a bare glassy carbon electrode
    Rutyna, Iwona
    Korolczuk, Mieczyslaw
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (12) : 1253 - 1260