Gender differences in the accuracy of dobutamine stress echocardiography for the diagnosis of coronary artery disease

被引:45
|
作者
Elhendy, A [1 ]
Geleijnse, ML [1 ]
vanDomburg, RT [1 ]
Nierop, PR [1 ]
Poldermans, D [1 ]
Bax, JJ [1 ]
TenCate, FJ [1 ]
Nosir, YFM [1 ]
Ibrahim, MM [1 ]
Roelandt, JRTC [1 ]
机构
[1] ERASMUS UNIV ROTTERDAM, UNIV HOSP DIJKZIGT, THORAXCTR, NL-3015 GD ROTTERDAM, NETHERLANDS
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1997年 / 80卷 / 11期
关键词
D O I
10.1016/S0002-9149(97)00707-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The accuracy of dobutamine stress echocardiography (DSE) for the diagnosis of coronary artery disease (CAD) has not been yet evaluated in women. We studied the effect of gender on the accuracy of DSE for the diagnosis of CAD in 306 consecutive patients (210 men and 96 women) with limited exercise capacity and suspected myocardial ischemia who underwent coronary angiography within 3 months of DSE. There were no serious complications during DSE. Men had a higher prevalence of nonsustained ventricular tachycardia (7% vs 0.03%, p <0.05) and supraventricular tachycardia (9% vs 0.03%, p <0.05) during the test compared with women. Peak stress rate-pressure product was not different in men and women (18,140 +/- 4,187 vs 18,543 +/- 4,223), Significant CAD (greater than or equal to 50% luminal diameter stenosis) was present in 171 men (81%) and in 62 women (65%, <0.005). The sensitivity, specificity, and accuracy of ischemic pattern at DSE for the diagnosis of significant CAD were 76% (confidence interval [CI] 67 to 84), 94% (CI 89 to 99), and 82% (CI 75 to 90) in women and 73% (CI 67 to 79), 77% (CI 71 to 83), and 74% (CI 68 to 80) in men, respectively. Overall specificity was higher in women than in men (p <0.05), Regional accuracy of DSE was significantly higher in women than in men in the 3 arterial regions (84% [CI 79 to 88] vs 75% [CI 72 to 79], p <0.005). It is concluded that DSE is a safe and Feasible method for the diagnosis of CAD in women. The overall specificity and the regional accuracy of DSE are higher in women than in men. Further studies are required to evaluate the functional significance of these findings and their reproducibility in different patient populations. (C) 1997 by Excerpta Medica, Inc.
引用
收藏
页码:1414 / 1418
页数:5
相关论文
共 50 条
  • [41] Feasibility, safety and accuracy of dobutamine/atropine stress echocardiography for the detection of coronary artery disease in renal transplant candidates
    Muniz Ferreira, Pedro Antonio
    de Lima, Valter Correia
    Campos Filho, Orlando
    Gil, Manuel Adan
    Cordovil, Adriana
    Machado, Cristiano Veira
    Medina Pestana, Jose Osmar
    de Camargo Carvalho, Antonio Carlos
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (01) : 45 - 51
  • [42] Stress echocardiography in the diagnosis of coronary artery disease.
    Mazur W.
    Nagueh S.F.
    Current Atherosclerosis Reports, 2001, 3 (2) : 109 - 116
  • [43] Stress echocardiography: refining the diagnosis of coronary artery disease
    Pinto, Fausto J.
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2006, 7 (07) : 470 - 471
  • [44] Accuracy of global and regional longitudinal strain at peak of dobutamine stress echocardiography to detect significant coronary artery disease
    Federica Ilardi
    Ciro Santoro
    Patrick Maréchal
    Raluca Dulgheru
    Adriana Postolache
    Roberta Esposito
    Giuseppe Giugliano
    Anna Sannino
    Marisa Avvedimento
    Attilio Leone
    Plinio Cirillo
    Eugenio Stabile
    Patrizio Lancellotti
    Giovanni Esposito
    The International Journal of Cardiovascular Imaging, 2021, 37 : 1321 - 1331
  • [45] Gender difference of diagnostic utility of dobutamine stress echocardiography with early atropine administration in detection of coronary artery disease
    Wierzbowska-Drabik, K.
    Roszczyk, N.
    Sobczak, M.
    Lipiec, P.
    Chrzanowski, L.
    Peruga, J. Z.
    Krecki, R.
    Plewka, M.
    Kasprzak, J. D.
    EUROPEAN HEART JOURNAL, 2012, 33 : 729 - 729
  • [46] Advantages of exercise echocardiography in comparison to dobutamine echocardiography in the diagnosis of coronary artery disease in hypertensive subjects
    T Pasierski
    H Szwed
    B Malczewska
    B Firek
    M Kośmicki
    M Rewicki
    I Kowalik
    Z Sadowski
    Journal of Human Hypertension, 2001, 15 : 805 - 809
  • [47] Advantages of exercise echocardiography in comparison to dobutamine echocardiography in the diagnosis of coronary artery disease in hypertensive subjects
    Pasierski, T
    Szwed, H
    Malczewska, B
    Firek, B
    Kosmicki, M
    Rewicki, M
    Kowalik, I
    Sadowski, Z
    JOURNAL OF HUMAN HYPERTENSION, 2001, 15 (11) : 805 - 809
  • [48] Dobutamine Stress Echocardiography in Anomalous Left Coronary Artery
    S.M. Leal
    A.C. Carvalho
    W. Mathias
    A.M. Arruda
    J.L. Andrade
    Pediatric Cardiology, 1998, 19 : 178 - 181
  • [49] Dobutamine stress echocardiography in anomalous left coronary artery
    Leal, SM
    Carvalho, AC
    Mathias, W
    Arruda, AM
    Andrade, JL
    PEDIATRIC CARDIOLOGY, 1998, 19 (02) : 178 - 181
  • [50] Dobutamine stress echocardiography in the detection of coronary artery disease: Importance of the pretest likelihood of disease
    Hennessy, TG
    Codd, MB
    Kane, G
    McCarthy, C
    McCann, HA
    Sugrue, DD
    AMERICAN HEART JOURNAL, 1997, 134 (04) : 685 - 692