Accuracy of reporting endocervical component adequacy - A continuous quality improvement project

被引:1
|
作者
Roberson, J [1 ]
Connolly, K [1 ]
St John, K [1 ]
Eltoum, I [1 ]
Chhieng, DC [1 ]
机构
[1] Univ Alabama, Dept Pathol, Birmingham, AL 35249 USA
关键词
cervicovaginal smears; endocervical component; adequacy; continuous quality improvement;
D O I
10.1002/dc.10162
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Inaccurate reporting of the absence of an endocervical (EC) component on Pap smears often results in slide rescreens, amended reports, clinician dissatisfaction, and sometimes unnecessary repeat smears. Therefore, the accuracy of reporting EC component adequacy was selected as a quality indicator for the laboratory continuous quality improvement program (CQI). The process consisted of problem identification, analysis of the situation, collection of data, implementation of solutions, and evaluation of results. The objective of the study was to determine if the accuracy of reporting EC component adequacy on Pap smears improved after application of such a program. During the first phase, 150 Pap smears originally reported with the absence of an adequate EC component and 150 smears reported with the presence of an adequate EC component were rescreened to measure the baseline accuracy of EC component adequacy reporting. The improvement process was then implemented. A cause-and-effect diagram was developed and root cause was determined. A presentation was then made to the cytology staff, Criteria for EC component adequacy were reviewed, examples were shown, and standardized marking of EC component was implemented. Following improvement actions, a second audit of 150 Pap smears reported with the absence of an adequate EC component as well as 150 smears reported with the presence of an adequate EC component was undertaken to measure change in performance in assessing EC component adequacy. For the baseline rescreening, before initiation of the CQI program, 98% accuracy was achieved with smears that were reported as adequate for EC component present. However, the accuracy with smears reported as absence of an adequate EC component was only 71%, i.e., an adequate EC component was identified in almost 113 of these cases on rescreen. After the implementation of improvement actions, the accuracy mained high (98%) and the accuracy of reporting the absence of EC component was 90%. The difference of the latter before and after the implementation was statistically significant (P = 0.015, z-test). The accuracy of reporting EC component adequacy increased following the CQI process. Using reporting EC component adequacy as an example, we demonstrate that by treating clinical problems as quality control issues and applying basic quality improvement tools, a positive outcome can be effected. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:181 / 184
页数:4
相关论文
共 50 条
  • [21] Expanding Data Reporting Capacity of Free and Charitable Clinics: A Quality Improvement Project
    Sposito, Rachel S.
    Selleck, Cynthia
    [J]. JOURNAL OF DOCTORAL NURSING PRACTICE, 2020, 13 (01) : 64 - 70
  • [22] 969 A Quality Improvement Project Centred Around the Introduction of an Exception Reporting Pathway
    Khudr, J.
    Bonsi, T.
    [J]. BRITISH JOURNAL OF SURGERY, 2022, 109 (SUPPL 6)
  • [23] Improving Recognition and Reporting of Adverse Drug Reactions in the NICU: A Quality Improvement Project
    Cammack, Betsy
    Oschman, Alexandra
    Lewis, Tamorah
    [J]. PEDIATRIC QUALITY & SAFETY, 2019, 4 (05) : E203
  • [24] Quality Improvement Project: for Improvement
    Hansen, Nora M.
    Scherer, Sally Anne
    Khan, Seema
    [J]. JOURNAL OF THE NATIONAL COMPREHENSIVE CANCER NETWORK, 2014, 12 : S10 - S12
  • [25] ASSESSMENT OF INPATIENT DIALYSIS ADEQUACY USING ON-LINE CLEARANCE: A FELLOW QUALITY IMPROVEMENT PROJECT
    Deewan, D.
    Nahman, S.
    Paulson, W. D.
    White, J.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2017, 65 (02) : 620 - 620
  • [26] Strengthening continuous quality improvement as an integral component of NAEYC's accreditation
    Goffin, SG
    [J]. YOUNG CHILDREN, 2001, 56 (03): : 51 - 51
  • [27] A continuous quality improvement project to reduce medication error in the emergency department
    Sara BC Lee
    Larry LY Lee
    Richard SD Yeung
    Jimmy TS Chan
    [J]. World Journal of Emergency Medicine, 2013, (03) : 179 - 182
  • [28] Determining intensive care unit requirements: A continuous quality improvement project
    Councell, C
    [J]. JOURNAL OF NURSING ADMINISTRATION, 1996, 26 (04): : 5 - 6
  • [29] A continuous quality improvement project to reduce medication error in the emergency department
    Sara BC Lee
    Larry LY Lee
    Richard SD Yeung
    Jimmy TS Chan
    [J]. World Journal of Emergency Medicine, 2013, 4 (03) - 182
  • [30] Continuous quality improvement in primary health care -: A five year project
    García, MTM
    De León, AC
    Lana, AT
    Méndez, LIP
    Montero, MAM
    López, AS
    [J]. EUROPEAN JOURNAL OF PUBLIC HEALTH, 1999, 9 (02): : 131 - 136