Accuracy of reporting endocervical component adequacy - A continuous quality improvement project

被引:1
|
作者
Roberson, J [1 ]
Connolly, K [1 ]
St John, K [1 ]
Eltoum, I [1 ]
Chhieng, DC [1 ]
机构
[1] Univ Alabama, Dept Pathol, Birmingham, AL 35249 USA
关键词
cervicovaginal smears; endocervical component; adequacy; continuous quality improvement;
D O I
10.1002/dc.10162
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Inaccurate reporting of the absence of an endocervical (EC) component on Pap smears often results in slide rescreens, amended reports, clinician dissatisfaction, and sometimes unnecessary repeat smears. Therefore, the accuracy of reporting EC component adequacy was selected as a quality indicator for the laboratory continuous quality improvement program (CQI). The process consisted of problem identification, analysis of the situation, collection of data, implementation of solutions, and evaluation of results. The objective of the study was to determine if the accuracy of reporting EC component adequacy on Pap smears improved after application of such a program. During the first phase, 150 Pap smears originally reported with the absence of an adequate EC component and 150 smears reported with the presence of an adequate EC component were rescreened to measure the baseline accuracy of EC component adequacy reporting. The improvement process was then implemented. A cause-and-effect diagram was developed and root cause was determined. A presentation was then made to the cytology staff, Criteria for EC component adequacy were reviewed, examples were shown, and standardized marking of EC component was implemented. Following improvement actions, a second audit of 150 Pap smears reported with the absence of an adequate EC component as well as 150 smears reported with the presence of an adequate EC component was undertaken to measure change in performance in assessing EC component adequacy. For the baseline rescreening, before initiation of the CQI program, 98% accuracy was achieved with smears that were reported as adequate for EC component present. However, the accuracy with smears reported as absence of an adequate EC component was only 71%, i.e., an adequate EC component was identified in almost 113 of these cases on rescreen. After the implementation of improvement actions, the accuracy mained high (98%) and the accuracy of reporting the absence of EC component was 90%. The difference of the latter before and after the implementation was statistically significant (P = 0.015, z-test). The accuracy of reporting EC component adequacy increased following the CQI process. Using reporting EC component adequacy as an example, we demonstrate that by treating clinical problems as quality control issues and applying basic quality improvement tools, a positive outcome can be effected. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:181 / 184
页数:4
相关论文
共 50 条
  • [1] Endocervical component: Is it a determinant of specimen adequacy?
    Selvaggi, SM
    Guidos, BJ
    [J]. DIAGNOSTIC CYTOPATHOLOGY, 2002, 26 (01) : 53 - 55
  • [2] Specimen adequacy and the ThinPrep® Pap Test™:: The endocervical component
    Selvaggi, SM
    Guidos, BJ
    [J]. DIAGNOSTIC CYTOPATHOLOGY, 2000, 23 (01) : 23 - 26
  • [3] REPORTING OF AN ENDOCERVICAL COMPONENT AFTER A PREVIOUS CERVICAL BIOPSY
    MITCHELL, H
    MEDLEY, G
    [J]. CYTOPATHOLOGY, 1991, 2 (04) : 177 - 180
  • [4] Improving the adequacy of hemodialysis: A renal network quality improvement project.
    Brier, ME
    Aronoff, GR
    Cain, J
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 : 696A - 696A
  • [5] Impact of endocervical component on specimen adequacy of false negative pap smears
    Peffer, Melissa
    Silverman, Jan
    Liu, Yulin
    Saad, Reda
    [J]. CANCER CYTOPATHOLOGY, 2006, 108 (05): : 385 - 385
  • [6] Ethics review as a component of institutional approval for a multicentre continuous quality improvement project: the investigator's perspective
    Ezzat, Hanna
    Ross, Sue
    von Dadelszen, Peter
    Morris, Tara
    Liston, Robert
    Magee, Laura A.
    [J]. BMC HEALTH SERVICES RESEARCH, 2010, 10
  • [7] Ethics review as a component of institutional approval for a multicentre continuous quality improvement project: the investigator's perspective
    Hanna Ezzat
    Sue Ross
    Peter von Dadelszen
    Tara Morris
    Robert Liston
    Laura A Magee
    [J]. BMC Health Services Research, 10
  • [8] The continuous improvement of the quality reporting system of a medium size company
    Hawkins, A
    Onuh, S
    [J]. INTERNET-BASED ENTERPRISE INTEGRATION AND MANAGEMENT, 2001, 4566 : 117 - 124
  • [9] Increasing service quality at a university: a continuous improvement project
    Gonzalez Aleu, Fernando
    Granda Gutierrez, Edgar Marco Aurelio
    Arturo Garza-Reyes, Jose
    Garza Villegas, Juan Baldemar
    Vazquez Hernandez, Jesus
    [J]. QUALITY ASSURANCE IN EDUCATION, 2021, 29 (2-3) : 209 - 224
  • [10] Neonatal Abstinence Syndome: A Continuous Quality Improvement Project
    Masalunga, Cynthia D.
    Dalere, Mente
    Fishman, Laurie
    Osterloh, Catherine
    Thornburg, Denise
    [J]. PEDIATRICS, 2018, 141