Reticular drusen over time with SD-OCT

被引:0
|
作者
Auge, J. [1 ]
Steinberg, J. S. [1 ]
Fleckenstein, M. [1 ]
Holz, F. G. [1 ]
Schmitz-Valckenberg, S. [1 ]
机构
[1] Univ Augenklin Bonn, D-53127 Bonn, Germany
来源
OPHTHALMOLOGE | 2014年 / 111卷 / 08期
关键词
Reticular pseudodrusen; Age-related macular degeneration; Confocal scanning laser ophthalmoscopy; Spectral-domain optical coherence tomography; Examination time points; AGE-RELATED MACULOPATHY; COMPLEMENT FACTOR-H; OPTICAL COHERENCE TOMOGRAPHY; MACULAR DEGENERATION; GEOGRAPHIC ATROPHY; POLYMORPHISM; PSEUDODRUSEN; PROGRESSION; DEPOSITS; EYE;
D O I
10.1007/s00347-013-2965-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The aim of the study was the analysis of reticular drusen (RDR) in patients with age-related macular degeneration using simultaneous confocal scanning laser ophthalmoscopy (cSLO) and spectral domain optical coherence tomography (SD-OCT) at different time points. Included in this retrospective analysis were 47 eyes from 32 patients (median age 80.1 years, range 66-89 years) with RDR at baseline and at least one follow-up visit. Registration of the cSLO near-infrared reflectance image and the SD-OCT B-scan (Spectralis HRA + OCT, Heidelberg Engineering, Heidelberg) at different time points was carried out using the AutoRescan tool. While either no alterations or increase in the RDR area (n = 19 eyes) or RDR density (n = 15) were seen by cSLO imaging, the analysis of the SD-OCT B-scans at different time points revealed a more complex picture. An increase in two well visible lesions at the baseline visit was detected in 8 eyes at the first follow-up and in 3 eyes at the second follow-up examination. A regression was seen in 5 eyes at the first follow-up and in 3 eyes at the second follow-up visit. In most eyes (n = 23), an increase of one with a parallel decrease of the second RDR lesion in the identical B-scan was identified at the first follow-up visit, whereas individual RDR showed an increase at the second follow-up examination that had initially shown a decrease in size at the first follow-up visit. The results indicate underlying dynamic processes in the development and changes of RDR over time. For a more accurate analysis, the exact registration of SD-OCT B-scans at different time points and the use of high-resolution very dense volume scans would be helpful in order to assess such discrete changes of miniscule intraretinal lesions over time.
引用
收藏
页码:765 / 771
页数:7
相关论文
共 50 条
  • [21] Identification of anterior chamber angle parameters with a portable SD-OCT device compared to a non-portable SD-OCT
    Akil, Handan
    Marion, Kenneth
    Dastiridou, Anna
    Jenkins, Dennis
    Kramer, Brendan
    Francis, Brian A.
    Chopra, Vikas
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (01) : 31 - 37
  • [22] Identification of anterior chamber angle parameters with a portable SD-OCT device compared to a non-portable SD-OCT
    Handan Akil
    Kenneth Marion
    Anna Dastiridou
    Dennis Jenkins
    Brendan Kramer
    Brian A. Francis
    Vikas Chopra
    [J]. International Ophthalmology, 2017, 37 : 31 - 37
  • [23] Combining FF-OCT with SD-OCT for retinal imaging
    Xiao, Peng
    Fink, Mathias
    Boccara, A. Claude
    [J]. OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA II, 2017, 10416
  • [24] Role of SD-OCT in pediatric glaucoma suspects
    Vonor, K.
    Koko, R. A. Kuaovi
    Santos, M.
    Ayena, K. D.
    Amedome, K. M.
    Dzidzinyo, K.
    Maneh, N.
    Banla, M.
    Balo, K. P.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2015, 38 (10): : E235 - E236
  • [25] Early Retinal Changes detected with SD-OCT
    Beutner, Andreas
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (07) : 820 - 820
  • [26] Detection of Glaucoma Progression by use of SD-OCT
    不详
    [J]. OPHTHALMOLOGE, 2016, 113 (12): : 1007 - 1007
  • [27] The Repeatability of Corneal Power Measurements with SD-OCT
    Wang, Yingjian
    Bagherinia, Homayoun
    Sha, Patricia
    Fard, Ali
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [28] Automatic montage of SD-OCT data sets
    Li, Ying
    Gregori, Giovanni
    Lam, Byron L.
    Rosenfeld, Philip J.
    [J]. OPTICS EXPRESS, 2011, 19 (27): : 26239 - 26248
  • [29] SD-OCT and autofluorescence characteristics of autoimmune retinopathy
    Pepple, Kathryn Lynn
    Cusick, Michael
    Jaffe, Glenn J.
    Mruthyunjaya, Prithvi
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (02) : 139 - 144
  • [30] An integrated time adaptive geographic atrophy prediction model for SD-OCT images
    Zhang, Yuhan
    Zhang, Xiwei
    Ji, Zexuan
    Niu, Sijie
    Leng, Theodore
    Rubin, Daniel L.
    Yuan, Songtao
    Chen, Qiang
    [J]. MEDICAL IMAGE ANALYSIS, 2021, 68