Fluorescence-based temperature control for polymerase chain reaction

被引:3
|
作者
Sanford, Lindsay N. [1 ]
Wittwer, Carl T. [2 ]
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Hlth Sci Ctr, Dept Pathol, Salt Lake City, UT 84112 USA
关键词
Polymerase chain reaction (PCR); Fluorescence; Temperature monitoring; High-resolution melting; LASER-INDUCED FLUORESCENCE; REAL-TIME PCR; VELOCITY-MEASUREMENTS; MELTING ANALYSIS; VELOCIMETRY; RESOLUTION; SYSTEM;
D O I
10.1016/j.ab.2013.11.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The ability to accurately monitor solution temperature is important for the polymerase chain reaction (PCR). Robust amplification during PCR is contingent on the solution reaching denaturation and annealing temperatures. By correlating temperature to the fluorescence of a passive dye, noninvasive monitoring of solution temperatures is possible. The temperature sensitivity of 22 fluorescent dyes was assessed. Emission spectra were monitored and the change in fluorescence between 45 and 95 degrees C was quantified. Seven dyes decreased in intensity as the temperature increased, and 15 were variable depending on the excitation wavelength. Sulforhodamine B (monosodium salt) exhibited a fold change in fluorescence of 2.85. Faster PCR minimizes cycling times and improves turnaround time, throughput, and specificity. If temperature measurements are accurate, no holding period is required even at rapid speeds. A custom instrument using fluorescence-based temperature monitoring with dynamic feedback control for temperature cycling amplified a fragment surrounding rs917118 from genomic DNA in 3 min and 45 s using 35 cycles, allowing subsequent genotyping by high-resolution melting analysis. Gold-standard thermocouple readings and fluorescence-based temperature differences were 0.29 +/- 0.17 and 0.96 +/- 0.26 degrees C at annealing and denaturation, respectively. This new method for temperature cycling may allow faster speeds for PCR than currently considered possible. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [21] Commercial nanodiamonds for precise fluorescence-based temperature sensing
    Pedroza-Montero, F. A.
    Santacruz-Gomez, K. J.
    Melendrez-Amavizca, R.
    Barboza-Flores, M.
    APPLIED PHYSICS LETTERS, 2024, 125 (07)
  • [22] Application of cascade control in the polymerase chain reaction
    Wang, Jinhe
    Zhang, Nan
    ICIEA 2008: 3RD IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, PROCEEDINGS, VOLS 1-3, 2008, : 2234 - 2238
  • [23] Routine analysis of p53 mutation in clinical breast tumor specimens using fluorescence-based polymerase chain reaction and single strand conformation polymorphism
    Iacopetta, B
    Elsaleh, H
    Grieu, F
    Joseph, D
    Sterrett, G
    Robbins, P
    DIAGNOSTIC MOLECULAR PATHOLOGY, 2000, 9 (01) : 20 - 25
  • [24] DETECTION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 BY USING THE POLYMERASE CHAIN-REACTION AND A TIME-RESOLVED FLUORESCENCE-BASED HYBRIDIZATION ASSAY
    DAHLEN, PO
    IITIA, AJ
    SKAGIUS, G
    FROSTELL, A
    NUNN, MF
    KWIATKOWSKI, M
    JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (04) : 798 - 804
  • [25] Detection of microsatellite instability by fluorescence multiplex polymerase chain reaction
    Berg, KD
    Glaser, CL
    Thompson, RE
    Hamilton, SR
    Griffin, CA
    Eshleman, JR
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2000, 2 (01): : 20 - 28
  • [26] Compact Fluorescence Detection System for Polymerase Chain Reaction Chips
    Lee, Deuk-Ju
    Hwang, Ji-Soo
    Park, Ji-Seong
    Park, Chan-Young
    Song, Hye-Jeong
    Kim, Yu-Seop
    Kim, Jong-Dae
    SENSORS AND MATERIALS, 2019, 31 (05) : 1635 - 1646
  • [27] A novel fluorescence quantification method for polymerase chain reaction system
    Chien, Jui Hung
    Lee, Da Sheng
    Cheng, Yi Ting
    Yeh, Shou Huei
    Chou, Wen Ping
    Chen, Ping Hei
    OPTICS COMMUNICATIONS, 2006, 266 (02) : 744 - 750
  • [28] An homogeneous fluorescence polymerase chain reaction assay to identify Salmonella
    Tseng, SY
    Macool, D
    Elliott, V
    Tice, G
    Jackson, R
    Barbour, M
    Amorese, D
    ANALYTICAL BIOCHEMISTRY, 1997, 245 (02) : 207 - 212
  • [29] An homogeneous fluorescence polymerase chain reaction assay to identify Salmonella
    Qualicon, DuPont Subsidiary, Route 141 and Henry Clay Road, Wilmington, DE 19880-0357, United States
    ANAL. BIOCHEM., 2 (207-212):
  • [30] Infrared temperature control system for a completely noncontact polymerase chain reaction in microfluidic chips
    Roper, Michael G.
    Easley, Christopher J.
    Legendre, Lindsay A.
    Humphrey, Joseph A. C.
    Landers, James P.
    ANALYTICAL CHEMISTRY, 2007, 79 (04) : 1294 - 1300