A study of the plasmasphere density distribution using computed tomography methods from the EUV radiation data

被引:12
|
作者
Li, Liang [1 ,2 ]
Chen, Zhiqiang [1 ,2 ]
Xu, Ronglan [3 ]
Kang, Kejun [1 ,2 ]
Zhang, Li [1 ,2 ]
Xing Yuxiang [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
[3] Chinese Acad Sci, Ctr Space & Appl Res, Beijing, Peoples R China
关键词
Computed tomography; Plasmasphere; Extreme ultraviolet (EUV); Reconstruction;
D O I
10.1016/j.asr.2008.10.013
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
In this paper. we introduce it new topic for imaging plasmasphere density with CT techniques. Both parallel-beam and fail-beam reconstruction formulas are derived with a special weighting function. Different from the traditional X-ray CT, the extreme ultraviolet (EUV) radiation may be totally absorbed by the Earth. Only the portion between the Earth and the detector enters the EUV sensor and be measured. The key step in our derivation is to remove the complete absorption effect with a specific weighting function. Computer-simulation studies are present to verify our formulas for the plasmasphere density. (C) 2008 COSPAR. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1143 / 1147
页数:5
相关论文
共 50 条
  • [21] Radiation dose reduction from low-kilovoltage liver computed tomography using multidetector row computed tomography
    Cho, Pyong-Kon
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (01) : 76 - 80
  • [22] From a "new kind of radiation" to tomography: A history of the computed tomography
    Vermandel, M.
    Marchandise, X.
    IRBM, 2009, 30 (02) : 33 - 39
  • [23] Radiation Exposure From Cardiac Computed Tomography
    Gosling, Oliver E.
    Roobottom, Carl A.
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (11) : 1201 - 1202
  • [24] Radiation Doses from Computed tomography in Iraq
    Al-Kinani, Athab
    Saddam, Ahmad
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2014, 47 (01): : 114 - 124
  • [25] Radiation risk to children from computed tomography
    Brody, Alan S.
    Frush, Donald P.
    Huda, Walter
    Brent, Robert L.
    PEDIATRICS, 2007, 120 (03) : 677 - 682
  • [26] Radiation risk to children from computed tomography
    Kirpalani, Haresh
    Nahmias, Claude
    PEDIATRICS, 2008, 121 (02) : 449 - 450
  • [27] Evaluation of Breast Tissue Segmentation Methods Using Supine and Prone Computed Tomography Data
    Juneja, P.
    Harris, E.
    Evans, P.
    Kirby, A.
    MEDICAL PHYSICS, 2011, 38 (06) : 3745 - +
  • [28] Radiation dose reduction in computed tomography perfusion using spatial-temporal Bayesian methods
    Fang, Ruogu
    Raj, Ashish
    Chen, Tsuhan
    Sanelli, Pina C.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [29] Thickness distribution of the glenohumeral joint cartilage: a quantitative study using computed tomography
    Zumstein, Valentin
    Kraljevic, Marko
    Conzen, Annemarie
    Hoechel, Sebastian
    Mueller-Gerbl, Magdalena
    SURGICAL AND RADIOLOGIC ANATOMY, 2014, 36 (04) : 327 - 331
  • [30] Computed Tomography as a Source of Electron Density Information for Radiation Treatment Planning
    Skrzyriski, Witold
    Zielinska-Dabrowska, Sylwia
    Wachowicz, Marta
    Slusarczyk-Kacprzyk, Wioletta
    Kukolowicz, Pawel F.
    Bulski, Wojciech
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 (06) : 327 - 333