Measuring Breathing Pattern in Patients With Chronic Obstructive Pulmonary Disease by Electrical Impedance Tomography

被引:19
|
作者
Balleza, Marco [1 ,2 ]
Calaf, Nuria [1 ]
Feixas, Teresa [1 ]
Gonzalez, Mercedes [1 ]
Anton, Daniel [2 ]
Riu, Pere J. [2 ]
Casan, Pere [1 ]
机构
[1] Univ Autonoma Barcelona, Unitat Funcio Pulmonar, Dept Pneumol, Hosp Santa Creu & St Pau,Fac Med, E-08193 Barcelona, Spain
[2] Univ Politecn Cataluna, Dept Elect Engn, Barcelona, Spain
来源
ARCHIVOS DE BRONCONEUMOLOGIA | 2009年 / 45卷 / 07期
关键词
Electrical impedance iomography (EIT); Breathing pattern; Pneumotacometer; Calibration; VALIDATION;
D O I
10.1016/j.arbres.2009.01.013
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background and Objective: The measurement of breathing pattern in patients with chronic obstructive pulmonary disease (COPD) by electrical impedance tomography (EIT) requires the use of a mathematical calibration model incorporating not only anthropometric characteristics (previously evaluated in healthy individuals) but probably functional alterations associated with COPD as well. The aim of this study was to analyze the association between Err measurements and spirometry parameters, static lung volumes, and carbon monoxide diffusing capacity (DLCO) in a group of male patients to develop a calibration equation for converting Err signals into volume signals. Materials and Methods: We measured forced vital capacity (FVC), forced expiratory volume in I second (FEV1), FEV1/FVC, residual volume, total lung capacity, DLCO, carbon monoxide transfer coefficient (KCO) and standard anthropometric parameters in 28 patients with a FEV1/FVC ratio of < 70%. We then compared tidal volume measurements from a previously validated EIT unit and a standard pneumotachometer. Results: The mean (SD) lung function results were FVC, 72 (16%); FEV1, 43% (14%); FEV1/FVC, 42% (9%); residual volume, 161% (44%); total lung capacity, 112% (17%): DLCO, 58% (17%); and KCO, 75% (25%). Mean (SD) tidal volumes measured by the pneumotachometer and the EIT unit were 0.697 (0.181)L and 0.515 (0.223) L, respectively (P <.001). Significant associations were found between EIT measurements and CO transfer parameters. The mathematical model developed to adjust for the differences between the 2 measurements (R-2 = 0.568; P<.001) was compensation factor = 1.81#-0.82# x height (m)#-0.004 x KCO (%) Conclusions: The measurement of breathing pattern by EIT in patients with COPD requires the use of a previously calculated calibration equation that incorporates not only individual anthropometric characteristics but gas exchange parameters as well. (C) 2008 SEPAR. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:320 / 324
页数:5
相关论文
共 50 条
  • [41] Electrical impedance tomography to determine optimal positive end-expiratory pressure in severe chronic obstructive pulmonary disease
    Kostakou, Eirini
    Barrett, Nicholas
    Camporota, Luigi
    CRITICAL CARE, 2016, 20
  • [42] THE EFFECTS OF ORAL ALMITRINE ON PATTERN OF BREATHING AND GAS-EXCHANGE IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE
    STRADLING, JR
    NICHOLL, CG
    COVER, D
    DAVIES, EE
    HUGHES, JMB
    PRIDE, NB
    CLINICAL SCIENCE, 1984, 66 (04) : 435 - 442
  • [43] Electrical impedance tomography for titration of positive end-expiratory pressure in acute respiratory distress syndrome patients with chronic obstructive pulmonary disease
    Liu, Xuesong
    Liu, Xiao
    Meng, Jue
    Liu, Dongdong
    Huang, Yongbo
    Sang, Ling
    Xu, Yonghao
    Xu, Zhiheng
    He, Weiqun
    Chen, Sibei
    Zhang, Rong
    Liu, Xiaoqing
    Li, Yimin
    CRITICAL CARE, 2022, 26 (01)
  • [44] Electrical impedance tomography for titration of positive end-expiratory pressure in acute respiratory distress syndrome patients with chronic obstructive pulmonary disease
    Xuesong Liu
    Xiao Liu
    Jue Meng
    Dongdong Liu
    Yongbo Huang
    Ling Sang
    Yonghao Xu
    Zhiheng Xu
    Weiqun He
    Sibei Chen
    Rong Zhang
    Xiaoqing Liu
    Yimin Li
    Critical Care, 26
  • [45] Assessment of respiratory impedance during deep-slow breathing with impulse oscillometry in patients with chronic obstructive pulmonary disease
    Liang Yong-jie
    Cai Ying-yun
    Chinese Journal of Integrative Medicine, 2003, 9 (4) : 266 - 269
  • [46] Breathing pattern and respiratory mechanics in chronically tracheostomized patients with chronic obstructive pulmonary disease breathing spontaneously through a hygroscopic condenser humidifier
    Vitacca, M
    Clini, E
    Porto, R
    Ambrosino, N
    RESPIRATION, 1997, 64 (04) : 263 - 267
  • [47] Breathing New Perspectives into Chronic Obstructive Pulmonary Disease
    Miller, Martin R.
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2015, 12 (02) : 113 - 114
  • [48] The Coordination of Breathing and Swallowing in Chronic Obstructive Pulmonary Disease
    Gross, Roxann Diez
    Atwood, Charles W., Jr.
    Ross, Sheryl B.
    Olszewski, Joan W.
    Eichhorn, Kimberly A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179 (07) : 559 - 565
  • [49] PATTERN OF COMPENSATORY RESPONSE TO CHRONIC HYPERCAPNIA IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY DISEASE
    EICHENHOLZ, A
    BLUMENTALS, AS
    WALKER, FE
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1966, 68 (02): : 265 - +
  • [50] Diaphragm length during tidal breathing in patients with chronic obstructive pulmonary disease
    Gorman, RB
    McKenzie, DK
    Pride, NB
    Tolman, JF
    Gandevia, SC
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (11) : 1461 - 1469