Factors influencing K-wire migration in tension-band wiring of olecranon fractures

被引:28
|
作者
Saeed, Zubair M. [1 ]
Trickett, Ryan W. [1 ]
Yewlett, Alun D. [1 ]
Matthews, Timothy J. W. [1 ]
机构
[1] Univ Wales Hosp, Dept Trauma & Orthopaed, Cardiff CF14 4XW, S Glam, Wales
关键词
Olecranon fracture; tension-band wiring; Kirschner wires; configuration; hardware failure; radiologic study; SURGICAL-TREATMENT; RISK-FACTORS; FIXATION; OSTEOSYNTHESIS; OSTEOPOROSIS; STABILITY; POSITION; FAILURE; WOMEN;
D O I
10.1016/j.jse.2014.02.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Tension-band wiring is a popular method of internal fixation for simple olecranon fractures. Although fracture union rates and clinical outcomes are good, up to 80% of patients require removal because of prominent/symptomatic metalwork. The current literature remains unclear as to the best orientation of the longitudinal wires to minimize hardware failure. The aim of this study was to determine the surgically modifiable factors related to spontaneous wire pullout. Methods: A retrospective review of hospital theater records over a period of 6 years was performed to identify all olecranon tension-band wire procedures. Preoperative radiographs were used to confirm and classify the fracture. Intraoperative and postoperative radiographs were analyzed for a number of wire-associated variables: wire length within the ulna, medullary/cortical position, parallelism of wires, proximal wire prominence, wire angle relative to the ulna, distance from the articular surface, fracture gap, and subsequent pullout. Results: A total of 182 wires were analyzed. The mean age was 52.5 years, and the mean radiographic follow-up period was 7.3 months. Intramedullary wires had a mean pullout of 5.5 mm compared with 2.4 mm for transcortical wires (P < .0001). A multiple regression model noted 7 independent variables affecting wire pullout: age, bent wires, medullary/transcortical wire positioning, proximal prominence, ulnar shaft angle, distance from the articular surface, and articular step. Conclusion: To minimize postoperative pullout of wires, we suggest anatomic reduction and transcortical wire orientation, without bending, in the subchondral bone close to the articular surface. Level of evidence: Level II, Retrospective Design, Prognosis Study. (C) 2014 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1181 / 1186
页数:6
相关论文
共 50 条
  • [41] DOUBLE TENSION BAND WIRING FOR TREATMENT OF OLECRANON FRACTURES - RESULTS AND LIMITATIONS
    GSCHWIND, C
    ALBERT, J
    REGAZZONI, P
    HARDER, F
    HELVETICA CHIRURGICA ACTA, 1987, 53 (05) : 599 - 602
  • [42] Biomechanical comparison of bi- and tricortical k-wire fixation in tension band wiring osteosynthesis
    J. Nowotny
    F. Bischoff
    T. Ahlfeld
    J. Goronzy
    E. Tille
    U. Nimtschke
    A. Biewener
    European Journal of Medical Research, 24
  • [43] Biomechanical comparison of bi- and tricortical k-wire fixation in tension band wiring osteosynthesis
    Nowotny, J.
    Bischoff, F.
    Ahlfeld, T.
    Goronzy, J.
    Tille, E.
    Nimtschke, U.
    Biewener, A.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2019, 24 (01)
  • [44] Functional Outcomes Following Plating or Tension Band Wiring of Olecranon Fractures
    Nadim Aslam
    Sunil Nair
    George Ampat
    Keith Willett
    European Journal of Trauma, 2003, 29 (5): : 273 - 277
  • [45] Use of Kirschner Wires With Eyelets for Tension Band Wiring of Olecranon Fractures
    Kim, Jin Young
    Lee, Young Ho
    Gong, Hyun Sik
    Lee, Sang Lim
    Lee, Sang Ki
    Baek, Goo Hyun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (09): : 1762 - 1767
  • [47] Tension band wiring for simple olecranon fractures: evaluation of surgical technique
    Claessen, Femke M. A. P.
    van den Bekerom, Michel P. J.
    van Dijk, C. Niek
    Goslings, J. Carel
    Kerkhoffs, Gino M. M. J.
    Doornberg, Job N.
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2017, 18 (03) : 275 - 281
  • [48] Tension-band wiring of closed transverse fractures of patella; effect of site of wire twists and orientation of stainless steel wire loop
    Afsar, Sardar Sohail
    Gulzar, Mohammad
    Idrees, Mohammad
    Babar, Iqtidar Uilah
    RAWAL MEDICAL JOURNAL, 2014, 39 (03): : 292 - 296
  • [50] A Comparative Study of Functional Outcome of Olecranon Fractures Managed with Tension band Wiring Using K Wires with Tension Band Wiring Using Cancellous Screws Fixation
    Parate, Ashutosh
    Gawande, Vasant
    Gupta, Suvarn
    Jaiwal, Ankit
    Chavan, Ashwin
    Saoji, Kunal
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (37A) : 193 - 198