Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study

被引:276
|
作者
Leung, Christopher Kai-Shun
Mohamed, Shaheeda
Leung, King Sai
Cheung, Carol Yim-Lui
Chan, Sylvia Lai-wa
Cheng, Daphne Ka-yee
Lee, August Ki-cheung
Leung, Gloria Yuk-oi
Rao, Srinivas Kamalakara
Lam, Dennis Shun Chiu
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Caritas Med Ctr, Dept Ophthalmol, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1167/iovs.06-0545
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the relationship between retinal nerve fiber layer (RNFL) thickness measured by optical coherence tomography (OCT) and the axial length/refractive error of the eye. METHODS. A total of 115 eyes of 115 healthy subjects, comprising 75 eyes with high myopia (spherical equivalent [SE] < - 6.0 D) and 40 eyes with low to moderate myopia (SE between - 6.0 D and - 0.5D), were analyzed in this cross-sectional study. Total average and mean clock hour RNFL thicknesses were measured by OCT and compared between the two myopia groups. Associations between RNFL measurements and axial length and spherical equivalent were evaluated by linear regression analysis. RESULTS. The RNFL measurements were significantly lower in the high myopia group compared with those of the low-tomoderate myopia group at 12, 1, and 7 o'clock (right eye orientation). Apart from the temporal clock hours, significant correlations were evident between RNFL measurements and the axial length and spherical equivalent. The average RNFL thickness decreased with increasing axial length (r = -0.314, P = 0.001) and negative refractive power (r = 0.291, P = 0.002). A significant proportion of myopic eyes were classified as outside normal limits, with reference to the normative database. The most frequently abnormal sector was at 2 o'clock, where 16.5% of myopic eyes were outside normal limits. CONCLUSIONS. RNFL measurements vary with the axial length/refractive error of the eye. Analysis of RNFL thickness in the evaluation of glaucoma should always be interpreted with reference to the refractive status. Although the normative database provided by OCT has been helpful in identifying ocular diseases involving the RNFL, it may not be reliable in the analysis of myopic eyes.
引用
收藏
页码:5171 / 5176
页数:6
相关论文
共 50 条
  • [1] Myopia Affects Retinal Nerve Fiber Layer Measurements as Determined by Optical Coherence Tomography
    Rauscher, Frederick M.
    Sekhon, Navneet
    Feuer, William L.
    Budenz, Donald L.
    [J]. JOURNAL OF GLAUCOMA, 2009, 18 (07) : 501 - 505
  • [2] Retinal nerve fibre layer thickness measurements in myopia by optical coherence tomography
    Bubella, R. Morreale
    Bubella, D. Morreale
    [J]. ACTA OPHTHALMOLOGICA, 2014, 92
  • [3] Assessment of Macula and Retinal Nerve Fiber Layer Thickness with Optical Coherence Tomography in Myopia
    Ozkagnici, Ahmet
    Tokgoz, Mine
    [J]. TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2012, 32 (02): : 415 - 427
  • [4] Evaluation of myopia on retinal nerve fiber layer thickness measured by Spectralis optical coherence tomography
    Zha, Yi
    Zhuang, Jinfei
    Lin, Da
    Feng, Wangqiang
    Zheng, Haihua
    Cai, Jianqiu
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (03) : 2716 - 2720
  • [5] Standard values and reproducibility of measurements of the retinal nerve fiber layer by optical coherence tomography
    Bernd, AS
    Klemm, M
    Walter, A
    Bohm, AG
    Leupold, N
    Breidenbach, K
    Messmer, M
    Claussen, M
    Pillunat, LE
    Richard, G
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3915 - 3915
  • [6] Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments
    Bourne, RRA
    Medeiros, FA
    Bowd, C
    Jahanbakhsh, K
    Zangwill, LM
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) : 1280 - 1285
  • [7] Optical coherence tomography measurements of the retinal nerve fiber layer profile in normal eyes
    Skaf, M
    Bernardes, ABS
    Cardillo, JA
    Costa, RA
    Melo-Jr, LAS
    Castro, JC
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U113 - U113
  • [8] Effect of Myopia on the Thickness of the Retinal Nerve Fiber Layer Measured by Cirrus Hd Optical Coherence Tomography
    Hong, S. W.
    Yoon, J.
    Park, C.
    Ahn, M.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [9] Effect of Myopia on the Thickness of the Retinal Nerve Fiber Layer Measured by Cirrus HD Optical Coherence Tomography
    Kang, Shin Hee
    Hong, Seung Woo
    Im, Seong Kyu
    Lee, Sang Hyup
    Ahn, Myung Douk
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (08) : 4075 - 4083
  • [10] Effect of Myopia on Retinal Nerve Fibre Layer Thickness Measurements by Cirrus HD Optical Coherence Tomography
    Singh, Divya
    Pathak, Mona
    Dada, Tanuj
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)