Estimating aerosol particle charging parameters using a Bayesian inversion technique
被引:13
|
作者:
Hogan, Christopher J., Jr.
论文数: 0引用数: 0
h-index: 0
机构:
Yale Univ, Dept Mech Engn, New Haven, CT 06520 USA
Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO USAYale Univ, Dept Mech Engn, New Haven, CT 06520 USA
Hogan, Christopher J., Jr.
[1
,2
]
Li, Lin
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO USAYale Univ, Dept Mech Engn, New Haven, CT 06520 USA
Li, Lin
[2
]
Chen, Da-ren
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO USAYale Univ, Dept Mech Engn, New Haven, CT 06520 USA
Chen, Da-ren
[2
]
Biswas, Pratim
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO USAYale Univ, Dept Mech Engn, New Haven, CT 06520 USA
Biswas, Pratim
[2
]
机构:
[1] Yale Univ, Dept Mech Engn, New Haven, CT 06520 USA
[2] Washington Univ, Dept Energy Environm & Chem Engn, St Louis, MO USA
Unipolar charging;
Data inversion;
Monte Carlo methods;
Electrical aerosol detector;
DIFFERENTIAL MOBILITY ANALYZER;
SURFACE-AREA;
NANOPARTICLES;
FIELD;
ELECTROSPRAY;
TRANSITION;
DIFFUSION;
MODEL;
PHOTOIONIZATION;
PERFORMANCE;
D O I:
10.1016/j.jaerosci.2008.11.008
中图分类号:
TQ [化学工业];
学科分类号:
0817 ;
摘要:
A Bayesian inversion routine is described in which data from tandem differential mobility analysis (TDMA) can be used to determine fundamental parameters for charging models as a function of particle size. The measurement and inversion techniques were verified using simulated data for particles in the 50-500 nm range undergoing unipolar diffusion charging as described by Fuchs' limiting sphere theory, for which the fundamental charging parameter is the product of the unipolar ion concentration and residence time within the charger, the so-called nt product. Under conditions where the average particle charge is greater than one unit charge, the inversion routine is precisely and accurately able to determine the nt value. The inversion routine breaks down, however, when the average number of charges per particle is well below unity, i.e. for low nt values or for small particle sizes. Incorporation of charging efficiency data in addition to TDMA data can allow for use of the inversion routine when the average number of charges per particle is low. With its limitations known, the inversion routine was applied to determine the nt value for the unipolar charger used in the TSI electrical aerosol detector (EAD), model 3070A, for particles in the 50-200 nm size range. The effective nt value within the EAD charger decreased with decreasing particle size, implying that charged particle losses occur within the EAD charger. The described inversion routine is unique in its ability to determine size dependent charge model parameters, and can be utilized with any given charging model. It is expected that this technique will be of use in advancing the understanding of aerosol particle charging models and in future design of unipolar chargers. (C) 2008 Elsevier Ltd. All rights reserved.
机构:
Consejo Nacl Invest Cient & Tecn, INTEC, RA-3000 Santa Fe, Argentina
Univ Nacl Litoral, RA-3000 Santa Fe, Argentina
Univ Tecnol Nacl, Fac Reg Santa Fe, RA-3000 Santa Fe, ArgentinaConsejo Nacl Invest Cient & Tecn, INTEC, RA-3000 Santa Fe, Argentina
Clementi, Luis A.
Vega, Jorge R.
论文数: 0引用数: 0
h-index: 0
机构:
Consejo Nacl Invest Cient & Tecn, INTEC, RA-3000 Santa Fe, Argentina
Univ Nacl Litoral, RA-3000 Santa Fe, Argentina
Univ Tecnol Nacl, Fac Reg Santa Fe, RA-3000 Santa Fe, ArgentinaConsejo Nacl Invest Cient & Tecn, INTEC, RA-3000 Santa Fe, Argentina
Vega, Jorge R.
Gugliotta, Luis M.
论文数: 0引用数: 0
h-index: 0
机构:
Consejo Nacl Invest Cient & Tecn, INTEC, RA-3000 Santa Fe, Argentina
Univ Nacl Litoral, RA-3000 Santa Fe, ArgentinaConsejo Nacl Invest Cient & Tecn, INTEC, RA-3000 Santa Fe, Argentina
Gugliotta, Luis M.
Orlande, Helcio R. B.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Rio de Janeiro, DEM PEM Politecn COPPE, BR-21941972 Rio De Janeiro, BrazilConsejo Nacl Invest Cient & Tecn, INTEC, RA-3000 Santa Fe, Argentina