Usefulness of Magnetic Resonance Imaging to Guide Referral for Pulmonary Valve Replacement in Repaired Tetralogy of Fallot

被引:8
|
作者
Lewis, Matthew J. [1 ]
O'Connor, Daniel S. [1 ]
Rozenshtien, Anna [2 ]
Ye, Siqin [1 ]
Einstein, Andrew J. [1 ]
Ginns, Jonathon M. [1 ]
Rosenbaum, Marlon S. [1 ]
机构
[1] Columbia Univ, Med Ctr, Dept Med, Div Cardiol, New York, NY 10027 USA
[2] Columbia Univ, Med Ctr, Dept Radiol, Div Thorac Imaging, New York, NY USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2014年 / 114卷 / 09期
关键词
CONGENITAL HEART-DISEASE; TERM-FOLLOW-UP; ADULTS; REGURGITATION; SURVIVORS; IMPACT;
D O I
10.1016/j.amjcard.2014.07.082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to determine if adult patients with repaired tetralogy of Fallot are being referred for pulmonary valve replacement (PVR) earlier on the basis of cardiac magnetic resonance imaging (CMR) parameters despite the absence of CMR-based recommendations in the American College of Cardiology and American Heart Association joint guidelines. Variables defined by the guidelines were analyzed in conjunction with CMR-based parameters across 3 groups defined by the release of the guidelines: (1) patients referred before the guidelines, (2) patients referred 0 to 3 years after the guidelines, and (3) patients >= 3 referred years after the guidelines. Seventy-nine patients were identified. No significant trend was observed in guideline-defined variables. Significant trends in indexed right ventricular end-diastolic volume (p = 0.034), indexed right ventricular end-systolic volume (p = 0.001), and the right ventricular ejection fraction (p = 0.005) were observed across groups. By multivariate regression, patients who underwent PVR >= 3 years after the release of the guidelines had a 29 ml/m(2) smaller indexed right ventricular end-diastolic volume (p = 0.01) and a 33 ml/m(2) smaller indexed right ventricular end-systolic volume (p < 0.001) compared with patients who underwent PVR before the release of the guidelines. PVR 0 to 3 years after the guidelines was not a significant predictor of either indexed right ventricular end-diastolic volume (p = 0.93) or indexed right ventricular end-systolic volume (p = 0.18). Patients referred for PVR >= years after the guidelines had significantly smaller CMR-based right ventricular volumes without significant trends in guideline-defined variables. Given the increased use of CMR to guide PVR referral, revisiting the guidelines to address appropriate use of CMR derived thresholds is indicated. (C) 2014 Elsevier Inc. All rights reserved.
引用
下载
收藏
页码:1406 / 1411
页数:6
相关论文
共 50 条
  • [21] Serial magnetic resonance imaging in children with repaired tetralogy of Fallot
    Parks, J
    Mahle, W
    Wu, GG
    Fyfe, D
    Brummer, M
    Oshinski, J
    CIRCULATION, 2003, 108 (17) : 566 - 567
  • [22] Comment on: "Improved Outcomes After Pulmonary Valve Replacement in Repaired Tetralogy of Fallot"
    Hudaib, Muhammad
    Malik, Hurais
    Rabbani, Samra
    CURRENT PROBLEMS IN CARDIOLOGY, 2023, 48 (10)
  • [23] Pulmonary Valve Replacement in Repaired Tetralogy of Fallot Appropriate Timing Saves Lives
    Menachem, Jonathan N.
    Opotowsky, Alexander R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (21) : 2086 - 2088
  • [24] Right ventricular strain in repaired Tetralogy of Fallot with regards to pulmonary valve replacement
    Monti, Caterina Beatrice
    Secchi, Francesco
    Capra, Davide
    Guarnieri, Gianluca
    Lastella, Giulia
    Barbaro, Ugo
    Carminati, Mario
    Sardanelli, Francesco
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
  • [25] Current Readings: Issues Surrounding Pulmonary Valve Replacement in Repaired Tetralogy of Fallot
    Kogon, Brian E.
    Rosenblum, Joshua M.
    Mori, Makoto
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2015, 27 (01) : 57 - 64
  • [26] CONSIDERATION OF OPTIMAL TIMING FOR PULMONARY VALVE REPLACEMENT IN ASYMPTOMATIC REPAIRED TETRALOGY OF FALLOT USING FEATURE TRACKING MAGNETIC RESONANCE STRAIN
    Inage, Akio
    Kishiki, Kanako
    Mizuno, Naokazu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 651 - 651
  • [27] Remodelling of the right ventricle after early pulmonary valve replacement in children with repaired tetralogy of Fallot: assessment by cardiovascular magnetic resonance
    Buechel, ERV
    Dave, HH
    Kellenberger, CJ
    Dodge-Khatami, A
    Pretre, R
    Berger, F
    Bauersfeld, U
    EUROPEAN HEART JOURNAL, 2005, 26 (24) : 2721 - 2727
  • [28] Surgical and transcatheter pulmonary valve replacement in patients with repaired tetralogy of Fallot: cardiac magnetic resonance imaging characteristics and morphology of right ventricular outflow tract
    Ozkok, Sercin
    Ciftci, Hatice Ozge
    Kose, Kevser Banu
    Yucel, Ilker Kemal
    Sasmazel, Ahmet
    Celebi, Ahmet
    Pekkan, Kerem
    PEDIATRIC RADIOLOGY, 2023, 53 (09) : 1863 - 1873
  • [29] Surgical and transcatheter pulmonary valve replacement in patients with repaired tetralogy of Fallot: cardiac magnetic resonance imaging characteristics and morphology of right ventricular outflow tract
    Sercin Ozkok
    Hatice Ozge Ciftci
    Kevser Banu Kose
    Ilker Kemal Yucel
    Ahmet Sasmazel
    Ahmet Celebi
    Kerem Pekkan
    Pediatric Radiology, 2023, 53 : 1863 - 1873
  • [30] Pulmonary Valve Replacement in Tetralogy of Fallot
    Weinberg, Catherine R.
    McElhinney, Doff B.
    CIRCULATION, 2014, 130 (09) : 795 - 798