Effectiveness of a new inflatable balloon device for gluing dissected layers in an experimental model of aortic dissection

被引:0
|
作者
Colak, Necmettin [1 ]
Nazli, Yunus [1 ]
Alpay, Mehmet Fatih [1 ]
Akkaya, Ismail Olgun [1 ]
Aksoy, Omer Nuri [1 ]
Akgedik, Sukran [2 ]
Cakir, Omer [1 ]
机构
[1] Fatih Univ, Sch Med, Dept Cardiovasc Surg, Ankara, Turkey
[2] Giresun State Hosp, Dept Pathol, Giresun, Turkey
来源
EXPERIMENTAL & CLINICAL CARDIOLOGY | 2013年 / 18卷 / 02期
关键词
Aortic dissection; New inflatable balloon device; Tissue gluing; BIOLOGIC GLUE; REPAIR;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: In the surgical treatment of acute aortic dissection, tissue glues are widely used to reinforce the adhesion between the dissected aortic layers. A new inflatable balloon device was developed to compress the dissected aortic wall during gluing to increase adhesion between the dissected layers. The present study used an ex vivo experimental animal model to test the hypothesis that this device is effective when gluing the true and false channels of dissected aortas. METHODS: In the ex vivo experimental model, aortic dissection was simulated surgically on 12 fresh bovine aorta samples. In six samples (group I), the inflatable balloon device was inserted into the aorta to reinforce and fuse the dissected layers during gluing. The other six fresh bovine aortic samples (group II) were compressed between the surgeon's fingers during gluing. Aortic samples were evaluated and compared macroscopically and histologically. RESULTS: In group I, adhesion between the dissected layers was easily achieved during gluing. All false cavities were perfectly closed, with no deleterious effects related to the device. In group II, the adhesion between the dissected layers was not complete and some false cavities remained patent. CONCLUSIONS: The inflatable balloon device can increase the adhesive effect of tissue glues via homogenous compression of the dissected aortic layers. In addition, the balloon can prevent distal embolization of the glue.
引用
收藏
页码:166 / 168
页数:3
相关论文
共 50 条
  • [41] A new experimental model of obstructive hydrocephalus in the rat: the micro-balloon technique
    Kim, DS
    Oi, S
    Hidaka, M
    Sato, O
    Choi, JU
    CHILDS NERVOUS SYSTEM, 1999, 15 (05) : 250 - 255
  • [42] A new experimental model of obstructive hydrocephalus in the rat: the micro-balloon technique
    D.-S. Kim
    Shizuo Oi
    Mitsuru Hidaka
    Osamu Sato
    Joong-Uhn Choi
    Child's Nervous System, 1999, 15 : 250 - 255
  • [43] Experimental evaluation of the patient-specific haemodynamics of an aortic dissection model using particle image velocimetry
    Franzetti, Gaia
    Bonfanti, Mirko
    Homer-Vanniasinkam, Shervanthi
    Diaz-Zuccarini, Vanessa
    Balabani, Stavroula
    JOURNAL OF BIOMECHANICS, 2022, 134
  • [44] Resuscitation And Hemodynamic Impact Of Aortic Balloon Occlusion And Percutaneous Left Ventricular Assist Device In A Swine Model Of Cardiac Arrest
    Tiba, Mohamad H.
    Nakashima, Takahiro
    McCracken, Brendan
    Hsu, Cindy H.
    Gottula, Adam
    Greer, Nicholas
    Cramer, Traci
    Sutton, Nadia R.
    Ward, Kevin R.
    CIRCULATION, 2022, 146
  • [45] DEVELOPMENT OF A NEW SELF-EXPANDABLE INTRAAORTIC GRAFT AND TRANSCATHETER ENTRY CLOSURE FOR EXPERIMENTAL AORTIC DISSECTION
    KATO, M
    MATUDA, T
    HIROSHIIMAGAWA
    UEDA, T
    YOSHIOKA, Y
    OHNISHI, K
    CIRCULATION, 1993, 88 (04) : 198 - 198
  • [46] Old Device, New Tricks Exploring Axillary Intra-Aortic Balloon Pump Use in Advanced Heart Failure
    Agarwal, Richa
    Rogers, Joseph G.
    JACC-HEART FAILURE, 2020, 8 (04) : 324 - 326
  • [47] Experimental evaluation of a new transcatheter vascular embolization device in the swine model
    Salamat, M
    Brown, PR
    Magee, CA
    Reyes, DK
    Peters, DN
    Venbrux, AC
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (03) : 301 - 311
  • [48] Concept and first experimental results of a new ferromagnetic assist device for extra-aortic counterpulsation
    Starck, Christoph T.
    Becker, Jakob
    Fuhrer, Roland
    Suendermann, Simon
    Stark, Jan Wendelin
    Falk, Volkmar
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 18 (01) : 13 - 16
  • [49] Challenging Colonoscopy: Safety and Effectiveness of a New ON-Demand Balloon Device for Facilitating Complete Colonoscopy in Challenging Patient Anatomy
    Halpern, Zamir
    Adler, Samuel N.
    Santo, Erwin M.
    GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 340 - 341
  • [50] A New Numerical Model of the Intra-aortic Balloon Pump as a Tool for Clinical Simulation and Outcome Prediction
    Marconi, Silvia
    Cappelli, Carla
    Capoccia, Massimo
    Pisanelli, Domenico M.
    Genuini, Igino
    De Lazzari, Claudio
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 795 - 799