Effectiveness of a new inflatable balloon device for gluing dissected layers in an experimental model of aortic dissection

被引:0
|
作者
Colak, Necmettin [1 ]
Nazli, Yunus [1 ]
Alpay, Mehmet Fatih [1 ]
Akkaya, Ismail Olgun [1 ]
Aksoy, Omer Nuri [1 ]
Akgedik, Sukran [2 ]
Cakir, Omer [1 ]
机构
[1] Fatih Univ, Sch Med, Dept Cardiovasc Surg, Ankara, Turkey
[2] Giresun State Hosp, Dept Pathol, Giresun, Turkey
来源
EXPERIMENTAL & CLINICAL CARDIOLOGY | 2013年 / 18卷 / 02期
关键词
Aortic dissection; New inflatable balloon device; Tissue gluing; BIOLOGIC GLUE; REPAIR;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: In the surgical treatment of acute aortic dissection, tissue glues are widely used to reinforce the adhesion between the dissected aortic layers. A new inflatable balloon device was developed to compress the dissected aortic wall during gluing to increase adhesion between the dissected layers. The present study used an ex vivo experimental animal model to test the hypothesis that this device is effective when gluing the true and false channels of dissected aortas. METHODS: In the ex vivo experimental model, aortic dissection was simulated surgically on 12 fresh bovine aorta samples. In six samples (group I), the inflatable balloon device was inserted into the aorta to reinforce and fuse the dissected layers during gluing. The other six fresh bovine aortic samples (group II) were compressed between the surgeon's fingers during gluing. Aortic samples were evaluated and compared macroscopically and histologically. RESULTS: In group I, adhesion between the dissected layers was easily achieved during gluing. All false cavities were perfectly closed, with no deleterious effects related to the device. In group II, the adhesion between the dissected layers was not complete and some false cavities remained patent. CONCLUSIONS: The inflatable balloon device can increase the adhesive effect of tissue glues via homogenous compression of the dissected aortic layers. In addition, the balloon can prevent distal embolization of the glue.
引用
收藏
页码:166 / 168
页数:3
相关论文
共 50 条
  • [1] Experimental confirmation of effectiveness of fenestration in acute aortic dissection
    Morales, DLS
    Quin, JA
    Braxton, JH
    Hammond, GL
    Gusberg, RJ
    Elefteriades, JA
    ANNALS OF THORACIC SURGERY, 1998, 66 (05): : 1679 - 1683
  • [2] Effectiveness of a New Ultrasonic Device in the Axillary Dissection
    Lo Russo, M.
    Lombardi, A.
    Maggi, S.
    Bartone, C.
    Gentili, I.
    Vitale, V.
    Bersigotti, L.
    Lazzarin, G.
    Amanti, C.
    EUROPEAN JOURNAL OF CANCER, 2012, 48 : S211 - S211
  • [3] A BALLOON-EXPANDABLE INTRAVASCULAR STENT FOR OBLITERATING EXPERIMENTAL AORTIC DISSECTION
    TRENT, MS
    PARSONNET, V
    SHOENFELD, R
    BRENER, BJ
    EISENBUD, DE
    NOVICK, AS
    CAMPBELL, AY
    FERRARARYAN, M
    VILLANUEVA, A
    JOURNAL OF VASCULAR SURGERY, 1990, 11 (05) : 707 - 717
  • [4] An Experimental Model of Stanford Type A Aortic Dissection
    Li, Ming
    Dong, Jianzeng
    Li, Ling
    Zhao, Xiaoyan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (16) : C3 - C3
  • [5] TRANSVASCULAR WINDOW IN A DISSECTED AORTIC-ANEURYSM - A NEW PROCEDURE FOR TREATING CIRCULATORY DISTURBANCES BY DISSECTION
    SCHILD, HH
    DUBER, C
    GREBE, P
    HAKE, U
    OELERT, H
    THELEN, M
    MEYER, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (02): : 164 - 167
  • [6] An experimental model of Stanford type B aortic dissection
    Terai, H
    Tamura, N
    Yuasa, S
    Nakamura, T
    Shimizu, Y
    Komeda, M
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (04) : 515 - 519
  • [7] An experimental model of Stanford type B aortic dissection
    Shimizu, Y
    Terai, H
    Tamura, N
    Yuasa, S
    Nakamura, T
    CIRCULATION, 1999, 100 (18) : 466 - 466
  • [8] Dissection Level Within Aortic Wall Layers is Associated with Propagation of Type B Aortic Dissection: A Swine Model Study
    Guo, Baolei
    Dong, Zhihui
    Pirola, Selene
    Liu, Yifan
    Menichini, Claudia
    Xu, Xiao Yun
    Guo, Daqiao
    Fu, Weiguo
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (03) : 415 - 425
  • [9] EFFECTIVENESS OF INTRA-AORTIC BALLOON COUNTERPULSATION IN EXPERIMENTAL LOW OUTPUT STATE
    TYBERG, JV
    KEON, WJ
    SONNENBLICK, EH
    URSCHEL, CW
    AMERICAN HEART JOURNAL, 1970, 80 (01) : 89 - +
  • [10] Expandable device type III for easy and reliable approximation of dissection layers in sutureless aortic anastomosis. Ex vivo experimental study
    Nazari, Stefano