Effect of configuration on the biomechanical performance of three suture materials used in combination with a metallic bone anchor

被引:0
|
作者
Wasik, Sonya M. [1 ]
Cross, Rod C. [2 ]
Voss, Katja [1 ]
机构
[1] Univ Sydney, Vet Teaching Hosp, Fac Vet Sci, Camperdown, NSW, Australia
[2] Univ Sydney, Fac Sci, Sch Phys, Sydney, NSW 2006, Australia
关键词
CANINE STIFLE JOINT; EXTRAARTICULAR STABILIZATION; IN-VITRO; DEFICIENT STIFLES; KNOT SECURITY; LEADER LINE; STRENGTH; FAILURE; STERILIZATION; ABRASION;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To determine whether different suture configurations could improve the biomechanical performance of 3 suture materials used with bone anchors. Samples-3 suture materials (60-lb test nylon leader line, size 2 polyblend polyethylene composite suture, and 150-lb test ultrahigh-molecular weight spun polyethylene). Procedures-Each suture material was looped through the eyelet of a metallic bone anchor and constructs were evaluated by use of an acute uniaxial load. Three configurations were tested for each suture material: single stranded (SS), double stranded (DS), and single stranded plus plastic insert (SSP). Force at failure, extension at failure, force at 3 mm of extension, stiffness, and site of failure of the suture were recorded for each test. Results-For all sutures, the DS configuration was the stiffest and yielded significantly higher forces at failure and forces at 3 mm of extension. The SS configuration had the lowest forces at failure. The SSP configuration yielded greater forces at failure for all suture materials, compared with the SS configuration, with a comparable stiffness. All sutures failed at the eyelet in the SS and DS configurations. In the SSP configuration, 60-lb test nylon leader line and 150-lb test ultrahigh-molecular weight spun polyethylene failed at the eyelet less frequently than did the polyblend composite suture. Conclusions and Clinical Relevance-Among the tested constructs, a DS suture configuration used in combination with the metallic bone anchor gave the best biomechanical results for all suture materials. Considering that the SSP configuration yielded greater forces at failure, compared with the SS configuration, covering metallic edges in bone anchors with softer materials might protect sutures and result in increased forces at failure.
引用
收藏
页码:1487 / 1492
页数:6
相关论文
共 50 条
  • [31] Formation of Porous Structure of the Metallic Materials Used on Bone Implants
    Seramak, Tomasz
    Serbinski, Waldemar
    Zielinski, Andrzej
    [J]. ENVIRONMENTAL DEGRADATION OF ENGINEERING & MATERIALS ENGINEERING AND TECHNOLOGIES, 2012, 183 : 155 - 162
  • [32] Biomechanical Stability of Knotless Suture Anchors Used in Rotator Cuff Repair in Healthy and Osteopenic Bone
    Pietschmann, Matthias F.
    Guelecyuez, Mehmet F.
    Fieseler, Sybille
    Hentschel, Markus
    Rossbach, Bjoern
    Jansson, Volkmar
    Mueller, Peter E.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (08): : 1035 - 1044
  • [33] Biomechanical properties of a suture anchor system from human allogenic mineralized cortical bone matrix for rotator cuff repair
    Schanda, Jakob E.
    Obermayer-Pietsch, Barbara
    Sommer, Gerhard
    Heuberer, Philipp R.
    Laky, Brenda
    Muschitz, Christian
    Pastl, Klaus
    Pastl, Eva
    Fialka, Christian
    Mittermayr, Rainer
    Grillari, Johannes
    Foessl, Ines
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [34] Biomechanical properties of a suture anchor system from human allogenic mineralized cortical bone matrix for rotator cuff repair
    Jakob E. Schanda
    Barbara Obermayer-Pietsch
    Gerhard Sommer
    Philipp R. Heuberer
    Brenda Laky
    Christian Muschitz
    Klaus Pastl
    Eva Pastl
    Christian Fialka
    Rainer Mittermayr
    Johannes Grillari
    Ines Foessl
    [J]. BMC Musculoskeletal Disorders, 23
  • [35] Biomechanical Comparison of Stability and Strength After Ulnar Collateral Ligament Reconstruction With Suture Anchor Fixation Versus Bone Tunnels
    Inagaki, Kenta
    Ochiai, Nobuyasu
    Hashimoto, Eiko
    Hattori, Fumiya
    Hiraoka, Yu
    Ise, Shohei
    Shimada, Yohei
    Ohtori, Seiji
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (09)
  • [36] Three anchor concepts for rotator cuff repair in standardized physiological and osteoporotic bone: a biomechanical study
    Rosso, Claudio
    Weber, Timo
    Dietschy, Alain
    de Wild, Michael
    Mueller, Sebastian
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (02) : E52 - E59
  • [37] Ex vivo biomechanical evaluation and comparison of lateral femoro-fabella ligament suture and lateral suture with bone anchor for cranial cruciate ligament repair in cats
    Tassani, Chiara
    de Witt, Anika A.
    Fosgate, Geoffrey T.
    Elliott, Ross C.
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2024, 85 (08)
  • [38] Rotator cuff repair with all-suture anchor enhances biomechanical properties and tendon-bone integration in a rabbit model
    Yu, Chengxuan
    Sun, Luyi
    Gao, Han
    Sheng, Huaixuan
    Feng, Xinting
    Yang, Xing
    Li, Jianbo
    Kong, Qingjun
    Hao, Yuefeng
    Feng, Sijia
    Chen, Jun
    [J]. HELIYON, 2024, 10 (18)
  • [39] THE EFFECT OF CORE CONFIGURATION ON THE COMPRESSIVE PERFORMANCE OF METALLIC SANDWICH PANELS
    Zurnaci, Erman
    Gokkaya, Hasan
    [J]. MATERIALI IN TEHNOLOGIJE, 2019, 53 (06): : 859 - 864
  • [40] A Transosseous Suture as an Alternative to Suture Anchor on Anterior-Avulsion Greater Tuberosity Fragment Fixation in Neer Three-Part Proximal Humeral Fracture: A Biomechanical Study
    Ju, Jiabao
    Ma, Mingtai
    Ding, Zhentao
    Zhang, Yichong
    Fu, Zhongguo
    Chen, Jianhai
    [J]. ORTHOPAEDIC SURGERY, 2023, 15 (08) : 2132 - 2137