Effect of configuration on the biomechanical performance of three suture materials used in combination with a metallic bone anchor

被引:0
|
作者
Wasik, Sonya M. [1 ]
Cross, Rod C. [2 ]
Voss, Katja [1 ]
机构
[1] Univ Sydney, Vet Teaching Hosp, Fac Vet Sci, Camperdown, NSW, Australia
[2] Univ Sydney, Fac Sci, Sch Phys, Sydney, NSW 2006, Australia
关键词
CANINE STIFLE JOINT; EXTRAARTICULAR STABILIZATION; IN-VITRO; DEFICIENT STIFLES; KNOT SECURITY; LEADER LINE; STRENGTH; FAILURE; STERILIZATION; ABRASION;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To determine whether different suture configurations could improve the biomechanical performance of 3 suture materials used with bone anchors. Samples-3 suture materials (60-lb test nylon leader line, size 2 polyblend polyethylene composite suture, and 150-lb test ultrahigh-molecular weight spun polyethylene). Procedures-Each suture material was looped through the eyelet of a metallic bone anchor and constructs were evaluated by use of an acute uniaxial load. Three configurations were tested for each suture material: single stranded (SS), double stranded (DS), and single stranded plus plastic insert (SSP). Force at failure, extension at failure, force at 3 mm of extension, stiffness, and site of failure of the suture were recorded for each test. Results-For all sutures, the DS configuration was the stiffest and yielded significantly higher forces at failure and forces at 3 mm of extension. The SS configuration had the lowest forces at failure. The SSP configuration yielded greater forces at failure for all suture materials, compared with the SS configuration, with a comparable stiffness. All sutures failed at the eyelet in the SS and DS configurations. In the SSP configuration, 60-lb test nylon leader line and 150-lb test ultrahigh-molecular weight spun polyethylene failed at the eyelet less frequently than did the polyblend composite suture. Conclusions and Clinical Relevance-Among the tested constructs, a DS suture configuration used in combination with the metallic bone anchor gave the best biomechanical results for all suture materials. Considering that the SSP configuration yielded greater forces at failure, compared with the SS configuration, covering metallic edges in bone anchors with softer materials might protect sutures and result in increased forces at failure.
引用
收藏
页码:1487 / 1492
页数:6
相关论文
共 50 条
  • [1] Biomechanical comparison of screw-in suture anchor–suture combinations used for Bankart repair
    Brad S. Sparks
    John Nyland
    Akbar Nawab
    Ethan Blackburn
    Ryan Krupp
    David N. M. Caborn
    [J]. Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 321 - 327
  • [2] Biomechanical comparison of screw-in suture anchor-suture combinations used for Bankart repair
    Sparks, Brad S.
    Nyland, John
    Nawab, Akbar
    Blackburn, Ethan
    Krupp, Ryan
    Caborn, David N. M.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (03) : 321 - 327
  • [3] Suture Anchor Fixation in Osteoporotic Bone: A Biomechanical Study in an Ovine Model
    Horoz, Levent
    Hapa, Onur
    Barber, F. Alan
    Husemoglu, Bugra
    Ozkan, Mustafa
    Havitcioglu, Hasan
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (01): : 68 - 74
  • [4] Comparison of biomechanical properties of periosteal suture fixation and bone anchor fixation to the pubic bone
    Winters, JC
    Fontenot, C
    Glowacki, C
    Thomas, KA
    Scarpero, H
    [J]. UROLOGY, 2000, 55 (06) : 866 - 869
  • [5] A biomechanical analysis of capsular plication versus anchor repair of the shoulder: Can the labrum be used as a suture anchor?
    Provencher, Matthew T.
    Verma, Nikhil
    Obopilwe, Eliffio
    Rincon, Lina M.
    Tracy, Jeremiah
    Romeo, Anthony A.
    Mazzocca, Augustus
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (02): : 210 - 216
  • [6] A systematic review of the biomechanical properties of suture materials used in orthopaedics
    Perez, Andres R.
    Coladonato, Carlo
    Muchintala, Rahul
    Christopher, Nicholas
    Matthews, John
    Tjoumakaris, Fotios P.
    Freedman, Kevin B.
    [J]. JOURNAL OF ORTHOPAEDICS, 2024, 51 : 122 - 129
  • [7] Biomechanical evaluation of suture materials used for abdominal fascial closure
    Ortiz de Elguea-Lizarraga, Jose Ignacio
    Segura-Ibarra, Victor
    Vazquez-Armendariz, Javier
    Lucia Garcia-Garcia, Ana
    Antonio Diaz-Elizondo, Jose
    Rodriguez, Ciro
    Flores-Villalba, Eduardo
    [J]. MATERIALS RESEARCH EXPRESS, 2021, 8 (11)
  • [8] Comparison of biomechanical properties of periosteal suture fixation and bone anchor fixation to the pubic bone - Comment
    Apell, RA
    [J]. UROLOGY, 2000, 55 (06) : 869 - 870
  • [10] Transosseous suture versus suture anchor fixation for inferior pole fractures of the patella in osteoporotic bone: a biomechanical study
    Jana Seggewiss
    Luis Fernando Nicolini
    Philipp Lichte
    Johannes Greven
    Marx Ribeiro
    Andreas Prescher
    Roman Michalik
    Christian Herren
    Philipp Kobbe
    Frank Hildebrand
    Miguel Pishnamaz
    [J]. European Journal of Medical Research, 27