FTIR-ATR Study of Water Uptake and Diffusion through Ion-Selective Membranes Based on Poly(acrylates) and Silicone Rubber

被引:66
|
作者
Sundfors, Fredrik [1 ]
Lindfors, Tom [1 ]
Hofler, Lajos [2 ]
Bereczki, Robert [2 ]
Gyurcsanyi, Robert E. [2 ,3 ]
机构
[1] Abo Akad Univ, Analyt Chem Lab, Proc Chem Ctr, FI-20500 Turku, Finland
[2] Budapest Univ Technol & Econ, Dept Inorgan & Analyt Chem, H-1111 Budapest, Hungary
[3] Budapest Univ Technol & Econ, Res Grp Tech Analyt Chem, Hungarian Acad Sci, H-1111 Budapest, Hungary
关键词
FIELD-EFFECT TRANSISTORS; LOW PLASTICIZER CONTENT; LOWER DETECTION LIMIT; NEUTRAL-CARRIER; POLYMERIC MEMBRANE; SOLID-CONTACT; POLY(METHYL METHACRYLATE); ELECTROCHEMICAL PERFORMANCE; POTENTIOMETRIC SENSORS; INTERMEDIATE PHASE;
D O I
10.1021/ac900727w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time, FTIR-ATR spectroscopy was used to study the water uptake and its diffusion in ion-selective membranes (ISMS) based on poly(acrylates) (PAS) and Silicone rubber (SR), which are emerging materials for the fabrication of ISMs for ultratrace analysis. Three different types of PA membranes were studied, consisting of copolymers of methyl methacrylate with n-butyl acrytate, decyl methacrylate, or isodecyl acrylate. Numerical simulations with the finite difference method showed that in most cases the water uptake of the PA and SR membranes could be described with a model consisting of two diffusion coefficients. The diffusion coefficients of the PA membranes were approximately 1 order of magnitude lower than those of plasticized poly(vinyl chloride) (PVC)-based ISMs and only slightly influenced by the membrane matrix composition. However, the simulations indicated that during longer contact times, the water uptake of PA membranes was considerably higher than that for plasticized PVC membranes. Although the diffusion coefficients of the SR and plasticized PVC membranes were similar, the SR membranes had the lowest water uptake of all membranes. This can be beneficial in preventing the formation of detrimental water layers in all-solid-state ionselective electrodes. With FTLR-ATR, one can monitor the accumulation of different forms of water, i.e., monomeric, dimeric, clustered, and bulk water.
引用
收藏
页码:5925 / 5934
页数:10
相关论文
共 50 条
  • [41] Water uptake in the hydrophilic poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) solid-contact of all-solid-state polymeric ion-selective electrodes
    Veder, Jean-Pierre
    De Marco, Roland
    Clarke, Graeme
    Jiang, San Ping
    Prince, Kathryn
    Pretsch, Ernoe
    Bakker, Eric
    ANALYST, 2011, 136 (16) : 3252 - 3258
  • [42] A computer simulation study on the diffusion and permeation of dimethylformamide/water mixtures through poly(vinyl alcohol)/poly(acrylic acid) blend membranes
    Zhong, Jing
    Yang, Baozhu
    Chen, Ruoyu
    Zhang, Qi
    Huang, Weiqiu
    Gu, Chi-ruei
    Chen, Cheng-lung
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2015, 94 : 681 - 690
  • [43] Ion-selective optical sensors based on the swelling of ionophore-doped poly(3-nitro-4-hydroxystyrene) microspheres incorporated into hydrogel membranes
    Wang, HM
    Seitz, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U152 - U152
  • [44] An Electrochemical Impedance Spectroscopy/Neutron Reflectometry Study of Water Uptake in the Poly(3,4-Ethylenedioxythiophene):Poly(Styrene Sulfonate)/Polymethyl Methacrylate-Polydecyl Methacrylate Copolymer Solid-Contact Ion-Selective Electrode
    Veder, Jean-Pierre
    Patel, Kunal
    Sohail, Manzar
    Jiang, San Ping
    James, Michael
    De Marco, Roland
    ELECTROANALYSIS, 2012, 24 (01) : 140 - 145
  • [45] Novel thallium(I) ion-selective electrodes with poly(vinyl chloride) membranes based on three noncyclic crown-type polyethers as suitable neutral ionophores
    Mohammad Reza Salavati
    Mahmoud Chamsaz
    Masoud Ghanei-Motlagh
    Hossein Eshghi
    Iman Razavipanah
    Journal of the Iranian Chemical Society, 2015, 12 : 335 - 345
  • [46] Novel thallium(I) ion-selective electrodes with poly(vinyl chloride) membranes based on three noncyclic crown-type polyethers as suitable neutral ionophores
    Salavati, Mohammad Reza
    Chamsaz, Mahmoud
    Ghanei-Motlagh, Masoud
    Eshghi, Hossein
    Razavipanah, Iman
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2015, 12 (02) : 335 - 345
  • [47] Measurement of diffusion coefficients for water transport through poly(styrene-b-isobutylene-b-styrene) based materials by ATR-IR spectroscopy
    Mountz, D
    Storey, R
    Mauritz, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U389 - U389
  • [48] FTIR-ATR SPECTROSCOPIC ANALYSIS OF BIS-CROWN ETHER BASED PVC-MEMBRANES .2. THE DIFFUSION BEHAVIOR OF K+-COMPLEXES IN THE SYSTEM OF PVC DIOCTYLSEBACATE CROWN-ETHER BME-44 - EX-SITU-STUDIES ON DRIED MEMBRANES
    KELLNER, R
    ZIPPEL, E
    PUNGOR, E
    TOTH, K
    LINDNER, E
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 328 (06): : 464 - 468
  • [49] Understanding the ion conductivity of self-standing poly-[ethylene oxide] composite films through non fickian diffusion mediated water uptake phenomena
    Das, Anamika
    Mukhopadhyay, Madhumita
    Mukhopadhyay, Jayanta
    Mishra, Shweta
    Sutradhar, Soumyaditya
    Sarkar, Anwita
    Kulsi, Goutam
    Biswas, Satarupa
    Mukherjee, Moumita
    JOURNAL OF POLYMER RESEARCH, 2024, 31 (09)
  • [50] Study of diffusion and sorption of bis-(2-chloroethyl)sulfide (SM) and bis-(2-chloroethyl)ether (OM) through polypropylene (PP) and biaxial-oriented polypropylene (BOPP) films by the FTIR-ATR spectroscopic method
    Semwal, RP
    Banerjee, S
    Chauhan, LR
    Bhattacharya, A
    Rao, NBSN
    JOURNAL OF APPLIED POLYMER SCIENCE, 1996, 60 (01) : 29 - 35