Directional sinogram interpolation for motion weighted 4D cone-beam CT reconstruction

被引:11
|
作者
Zhang, Hua [1 ]
Kruis, Matthijs [1 ]
Sonke, Jan-Jakob [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 06期
关键词
4D cone-beam CT; directional interpolation; image quality; DEFORMABLE REGISTRATION; COMPUTED-TOMOGRAPHY; STRATEGIES; ARTIFACTS;
D O I
10.1088/1361-6560/aa5b6e
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The image quality of respiratory sorted four-dimensional (4D) cone-beam (CB) computed tomography (CT) is often limited by streak artifacts due to insufficient projections. A motion weighted reconstruction (MWR) method is proposed to decrease streak artifacts and improve image quality. Firstly, respiratory correlated CBCT projections were interpolated by directional sinogram interpolation (DSI) to generate additional CB projections for each phase and subsequently reconstructed. Secondly, local motion was estimated by deformable image registration of the interpolated 4D CBCT. Thirdly, a regular 3D FDK CBCT was reconstructed from the non-interpolated projections. Finally, weights were assigned to each voxel, based on the local motion, and then were used to combine the 3D FDK CBCT and interpolated 4D CBCT to generate the final 4D image. MWR method was compared with regular 4D CBCT scans as well as McKinnon and Bates (MKB) based reconstructions. Comparisons were made in terms of (1) comparing the steepness of an extracted profile from the boundary of the region-of-interest (ROI), (2) contrast-to-noise ratio (CNR) inside certain ROIs, and (3) the root-mean- square-error (RMSE) between the planning CT and CBCT inside a homogeneous moving region. Comparisons were made for both a phantom and four patient scans. In a 4D phantom, RMSE were reduced by 24.7% and 38.7% for MKB and MWR respectively, compared to conventional 4D CBCT. Meanwhile, interpolation induced blur was minimal in static regions for MWR based reconstructions. In regions with considerable respiratory motion, image blur using MWR is less than the MKB and 3D Feldkamp (FDK) methods. In the lung cancer patients, average CNRs of MKB, DSI and MWR improved by a factor 1.7, 2.8 and 3.5 respectively relative to 4D FDK. MWR effectively reduces RMSE in 4D cone-beam CT and improves the image quality in both the static and respiratory moving regions compared to 4D FDK and MKB methods.
引用
收藏
页码:2254 / 2275
页数:22
相关论文
共 50 条
  • [21] Aperture weighted cardiac reconstruction for cone-beam CT
    Koken, P.
    Grass, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14): : 3433 - 3448
  • [22] Motion-Compensated 4D Cone-Beam Computed Tomography
    Brehm, Marcus
    Berkus, Timo
    Oehlhafen, Markus
    Kunz, Patrik
    Kachelriess, Marc
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3986 - 3993
  • [23] 4D Cone-Beam CT reconstruction with 60s acquisition and 60s reconstruction
    Hansen, D.
    Sorensen, T.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S177 - S178
  • [24] Iterative volume of interest based 4D cone-beam CT
    Martin, Rachael
    Ahmad, Moiz
    Hugo, Geoffrey
    Pan, Tinsu
    [J]. MEDICAL PHYSICS, 2017, 44 (12) : 6515 - 6528
  • [25] Sliding window cone-beam CT reconstruction for biopsy guidance in 4D CT fluoroscopy: A simulation study
    Grass, M
    Bontus, C
    Koehler, T
    Renisch, S
    Proksa, R
    [J]. RADIOLOGY, 2001, 221 : 424 - 424
  • [26] Assess Interfractional Tumor Motion in SBRT Lung Treatment Using 4D Cone-Beam CT
    Li, J.
    Yu, Y.
    Xiao, Y.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [27] GPU-Based 4D Cone-Beam CT Reconstruction Using Adaptive Meshing Method
    Zhong, Z.
    Gu, X.
    Iyengar, P.
    Mao, W.
    Guo, X.
    Wang, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3219 - 3219
  • [28] Data-driven rapid 4D cone-beam CT reconstruction for new generation linacs
    Gardner, Mark
    Dillon, Owen
    Byrne, Hilary
    Keall, Paul
    O'Brien, Ricky
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (18):
  • [29] Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy
    Li, Tianfang
    Xing, Lei
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04): : 1211 - 1219
  • [30] Motion vector field phase-to-amplitude resampling for 4D motion-compensated cone-beam CT
    Sauppe, Sebastian
    Kuhm, Julian
    Brehm, Marcus
    Paysan, Pascal
    Seghers, Dieter
    Kachelriess, Marc
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):